Skip to content

Scaffold system

Layher Blitz scaffold: bay lengths, depths and parts list

Layher Blitz has bay lengths of 1.57–3.07 m and depths of 1.09 m and 0.73 m in ScaFix. Enter your walls, and ScaFix draws the Layher Blitz scaffold in 3D and works out its parts list. A straight wall with its full parts list: Layher Blitz (12.28 × 4 m, 24.56 × 8 m). Any other size: Scaffold calculator.

· How the numbers are computed ·

Layher Blitz scaffolding around a house of 11.4 × 5.3 m with a gabled roof (eaves 4.5 m, ridge 6 m), drawn by the ScaFix 3D model
Layher Blitz around the example house, as ScaFix draws it in 3D.

How many parts does Layher Blitz need for a house?

ScaFix plans Layher Blitz with the bay lengths 3.07 m, 2.57 m, 2.07 m and 1.57 m and scaffold depth 1.09 m and 0.73 m. On ScaFix’s 11.4 m × 5.3 m example house, scaffolded all round, Layher Blitz needs 263 parts; Jamax needs 376 on the same house.

Scaffold calculator

Result

12 m × 6 m wall, Layher Blitz (3.07m)

Bays
4 (4 × 3.07 m)
Lifts
3
Decked levels
2 (2.05 m and 4.05 m)
Scaffold area
62.0 m²

Build this wall in 3D

Layher Blitz in brief

Layher Blitz is Layher's steel frame scaffold for facades, approved by the DIBt as Blitz Gerüst 70 Stahl under Z-8.1-16.2 (2 January 2025, valid until 4 January 2030; first approved in 1973). The approval's regular design is load class 3; heavier masonry work needs its own proof, usually with shorter bays.

ScaFix plans it with bays of 3.07 m, 2.57 m, 2.07 m and 1.57 m and depths of 1.09 m and 0.73 m; ScaFix plans the parts, it does not approve the scaffold.

What is Layher Blitz?

Layher Blitz is planned with bays of 1.57 to 3.07 m at 0.73 or 1.09 m deep, the example house with the 3.07 m bay; shorter bays can be chosen in Pro; its steel frames, decks and guardrails make it the quick facade scaffold of the Layher range, and Allround is the modular partner for corners and towers.

What does the Layher Blitz documentation warn about?

Approval Z-8.1-16.2 (Anlage B p. 3, §B.5) forbids V-anchors on the outer frame lines; where a level has no free inner standard, long scaffold ties take their place (Tab. B.2). With some plywood or combination decks a V-anchor also needs a horizontal strut under it (Anlage C p. 20), which ScaFix states as a note.

What bay lengths and depths does Layher Blitz have?

For Layher Blitz, ScaFix offers 4 bay lengths, 3.07 m, 2.57 m, 2.07 m and 1.57 m, and 2 depths, 1.09 m and 0.73 m. Its longest wall on the example house, 11.4 m, is planned as 4 × 3.07 m at 0.73 m deep in 2 m lifts, tied every 4 m in height.

Manufacturer · System type
Layher · Frame scaffold (facade scaffold)
Variants in the system picker
Layher Blitz (3.07 m), Layher Blitz (2.57 m), Layher Blitz (2.07 m), Layher Blitz (1.57 m), Layher Blitz (Mixed)
Bay lengths · Depths
3.07 m, 2.57 m, 2.07 m, 1.57 m · 1.09 m, 0.73 m
Source
DIBt approval Z-8.1-16.2 (dibt.de, PDF)
How ScaFix plans Layher Blitz
2 m lifts; ties every 4 m vertically, every 3.07 m (1 × 3.07 m) along the wall; diagonals at least one per 5 bays in every lift

How far apart are Layher Blitz wall ties?

Layher Blitz wall ties sit every 4 m in height and every 3.07 m along the wall with the 3.07 m bay. Rule: DIBt Z-8.1-16.2 Anlage B p. 1 §B.1 + p. 4 §B.5 b. The lowest Layher Blitz tie row sits no higher than 4 m.

Wall-tie spacing along the wall for each bay length of Layher Blitz in ScaFix
Bay lengthBays between tiesTie spacing along the wall
3.07 m13.07 m

How each system's tie rule was checked, with its source: verification status of all systems.

Software for Layher Blitz: LayPLAN or ScaFix?

Choose LayPLAN when you work only with Layher material and plan in Windows or inside AutoCAD or BricsCAD. Choose ScaFix when you want Layher Blitz as a 3D model with the full parts list from wall measurements or a PDF drawing, in the browser or on the iPhone, without installing CAD.

Full comparison: ScaFix vs Layher LayPLAN.

Layher LayPLANScaFix
Made forLayher systems only (Allround, SpeedyScaf/Blitz, AGS and more)115 systems from 57 manufacturers, Layher Blitz included
Runs onWindows 7, 10 and 11; LayPLAN CAD inside AutoCAD or BricsCADBrowser (PC, Mac, Android) and iPhone app
OutputMaterial list in real time, CAD drawings, link to RSTAB for structural checks3D model and full parts list; PDF report from Basic, CSV/Excel export and quotes in Pro; no structural calculation
PriceNot published on layher.com (checked 28 October 2026): usable for 30 days after installation, then a licence through myLayherYearly plans Basic and Pro; prices on the ScaFix price page

Sources for Layher Blitz

Tie rule for Layher Blitz: DIBt Z-8.1-16.2 Anlage B p. 1 §B.1 + p. 4 §B.5 b. The approval document for DIBt Z-8.1-16.2, as the DIBt publishes it. ScaFix is a planning tool, not a structural approval.

Close-ups from the 3D model

The example house with Layher Blitz

The walls of the example house with Layher Blitz
WallLengthHeightBays
Wall 1 + 311.4 m4.5 m4 × 3.07 m
Wall 2 + 4 (gable)5.3 m6 m2 × 3.07 m

What is on the Layher Blitz parts list for the example house?

For the example house, Layher Blitz needs 263 parts: 0.73 m deep, ladder access, decks at 2.05 m and 4.05 m. The list is led by wall ties and fittings (56), frames and standards (44) and guardrails (36). Wall ties and fittings make up 21 % of the 263 parts.

What is on the Layher Blitz parts list for the example house?
PartLengthCount
Frames and standards
Frames2 m32
Top-lift guardrail posts12
Decks
Decks without ladder3.07 m23
Decks with ladder3.07 m2
Guardrails
Front guardrails3.07 m36
Toeboards
Toeboards3.07 m24
Diagonals
Diagonals3.07 m24
Ends
End guardrails8
End guardrail frames (top lift)4
End toeboards8
Wall ties and fittings
Wall ties24
Wall-anchor fittings24
Right-angle couplers for wall ties8
Base jacks and legs
Base jacks / legs32
Base transoms2

Layher Blitz · Scaffold depth: 0.73 m · Decks at: 2.05 m, 4.05 m · Decks with ladders · Parts in all: 263

Calculated with ScaFix, a scaffold planning app for browser and iPhone (115 scaffold systems from 57 manufacturers, checked 10 November 2026).

How does Layher Blitz compare with similar systems?

Layher Blitz needs 263 parts on the example house, compared with Jamax (376, +113), Plettac SL 70/100 (316, +53) and Hünnebeck BOSTA 70/100 (324, +61). Only Plettac SL 70/100 gets within 53 parts, at the same 0.73 m depth. From lowest to highest, the totals differ by 113 parts.

The example house with Layher Blitz and similar systems
SystemBays on the long wallDepthParts in allAgainst Layher Blitz
Layher Blitz4 × 3.07 m0.73 m263this page
Jamax4 × 3 m0.68 m376+113 (+43%)
Plettac SL 70/1001 × 1.5 m + 3 × 3 m + 1 × 2.5 m0.73 m316+53 (+20%)
Hünnebeck BOSTA 70/1001 × 2 m + 3 × 3 m + 1 × 2.5 m0.73 m324+61 (+23%)

Layher Blitz against Jamax and Plettac SL 70/100, family by family

Against Jamax (376 parts) on the example house, the Layher Blitz list (263) has 104 fewer system-specific parts, 40 fewer wall ties and fittings and 24 more diagonals. Against Plettac SL 70/100 (316), it has 32 fewer wall ties and fittings, 16 more diagonals and 16 fewer frames and standards.

Only the Layher Blitz list carries end guardrail frames (top lift, 4) and base transoms (2); the lists of Jamax and Plettac SL 70/100 have no such row. The Jamax list has couplers (104), which the Layher Blitz list does not.

How many parts does Layher Blitz need per wall size?

Wall size drives the count for Layher Blitz: 40 parts at 6.14 × 4 m, 382 at 30.7 × 12 m, 0.73 m deep. A 12.28 × 6 m wall comes to 96 parts including 12 ties, and the 30.7 × 12 m wall 42 ties.

Parts by wall size with Layher Blitz
Wall (length × height)BaysDecked liftsFrames and standardsDecksBase jacks and legsWall ties and fittingsParts in all
6.14 × 4 m2 × 3.07 m1438940
12.28 × 6 m4 × 3.07 m2139122696
18.42 × 8 m6 × 3.07 m326191640165
24.56 × 10 m8 × 3.07 m443332072273
30.7 × 12 m10 × 3.07 m564512493382

Layher Blitz: technical data in ScaFix

Layher Blitz: technical data in ScaFix
ItemValue in ScaFixDocument
First tie row, at most4 mDIBt Z-8.1-16.2 Anlage B p. 1 §B.1 + p. 4 §B.5 b
V-anchors per tie level1 per started 5 tied standards per levelDIBt Z-8.1-16.2 Anlage B p. 1 §B.1 + p. 4 §B.5 b
Tie rows behind a net, as ScaFix plans them2 m (ScaFix’s minimum; Z-8.1-16.2 Tab. B.2: 4 m grid)Layher SpeedyScaf NO 2024 p. 28 fig. 57c + p. 46; DIBt Z-8.1-16.2 Tab. B.2 p. 5 row 4, Anlage C p. 4–5 (PDF S. 270–271)
Tie rows under a tarpaulin2 m, every node (Z-8.1-16.2 Tab. B.2, console configuration 2 only)DIBt Z-8.1-16.2 Tab. B.2 p. 5 (PDF S. 257), Anlage C p. 7–8 (PDF S. 273–274); Layher SpeedyScaf NO 2024 p. 27 + p. 46
Anchoring calculated above (top platform)24 mDIBt Z-8.1-16.2 Anlage B p. 1 §B.1 + p. 4 §B.5 b
Access decks with ladder, bay lengths2.57 m and 3.07 mLayher SpeedyScaf monteringsveiledning March 2024 REV2 p. 29, p. 50, p. 51; RISE C900113; DIBt Z-8.1-16.2 Tabelle 1
Hatch decks without ladder, bay lengths1.57 m and 2.07 mLayher SpeedyScaf monteringsveiledning March 2024 REV2 p. 29, p. 50, p. 51; RISE C900113; DIBt Z-8.1-16.2 Tabelle 1
Separate access ladder4009.007 · 2.15 mLayher SpeedyScaf monteringsveiledning March 2024 REV2 p. 50 pos. 6 «Etasjestige 2,15m for både AR og BL T19 … 4009.007»; RISE C900113

How ScaFix builds Layher Blitz: lifts, bottom rail, ties and access

  • Bottom lift. In the bottom lift of Layher Blitz ScaFix fits one guardrail frame per bay on the outer face, also where the lift carries no deck (Layher DOC0071 p. 3 (3, 5c)). Each lowest bay with a diagonal also gets a horizontal strut at foot height (Layher Rammestillas monteringsveiledning NO 2017 p. 17, p. 19 step 6, p. 26).
  • Wall ties. With roof-edge brackets, every standard is tied on the bracket level (DIBt Z-8.1-16.2 Anlage C p. 1–3 (PDF S. 267–269)).
  • Net and tarpaulin. A clad Layher Blitz needs more ties, and the pattern depends on the document your site works to. The German approval Z-8.1-16.2 covers nets and tarpaulins in its standard build up to 24 m (Annex B §B.1): with a net, ties on the 4 m grid, or 8 m staggered before a closed façade with the edge lines every 4 m and every standard tied at the top level; with a tarpaulin only in console configuration 2, every node every 2 m (§B.5, Tab. B.2). Layher’s Norwegian assembly guide says cladding needs extra ties and shows one pattern under a net as an example (2024, p. 27, p. 28 fig. 57c); its cladding section is outside the product certificate (p. 46), and RISE C900113 gives no pattern for a clad scaffold. ScaFix therefore plans tie rows every 2 m under a net or a tarpaulin as its own minimum, not as Layher’s figure, and marks the wall «calculation required»: have the ties of a clad scaffold calculated or confirmed against the document that applies on your site.
  • Access. Layher Blitz is climbed inside the scaffold, through access decks with a built-in ladder, which the maker lists for the 2.57 m and 3.07 m bays (Layher SpeedyScaf monteringsveiledning March 2024 REV2 p. 29, p. 50, p. 51; RISE C900113; DIBt Z-8.1-16.2 Tabelle 1).
  • Notices in the editor. With plywood frame decks or stackable combi decks (in the approval: U-Rahmentafeln Sperrholz, U-Stapel-Kombiböden), some V-anchors need an extra horizontal strut or coupling tube right under them, clamped to the inner standards (Z-8.1-16.2 Annex B p. 4 § B.5, detail Annex C p. 20). The app does not know the deck type, so the strut/tube is not on the parts list.

Layher Blitz on a 12 m × 6 m wall: pieces and estimated weight

Layher Blitz on a 12 m × 6 m wall: pieces and estimated weight
Part groupPiecesEstimated weight
Frames and standards13206 kg
Decks9212 kg
Guardrails12169 kg
Toeboards846 kg
Diagonals648 kg
Ends1050 kg
Wall ties and fittings2636 kg
Base jacks and legs1244 kg
In all96811 kg

Documents behind the Layher Blitz rules in ScaFix

Documents behind the Layher Blitz rules in ScaFix
Used forDocument and passage
Bay lengths and depthsRISE C900113 ed. 2 p. 2 + DIBt Z-8.1-16.2 Tab. B.9
Ties at roof-edge bracketsDIBt Z-8.1-16.2 Anlage C p. 1–3 (PDF S. 267–269)
Guardrail in the bottom liftLayher DOC0071 p. 3 (3, 5c)
Foot-height member in braced baysLayher Rammestillas monteringsveiledning NO 2017 p. 17, p. 19 step 6, p. 26

Compare Layher Blitz

Closest to Layher Blitz by type and longest bay in ScaFix’s catalogue: KERO RK 073 (same type, longest bay 3.07 m), Layher Allround STAR 70 (same maker, same type, longest bay 3.07 m) and MJ UNI-CONNECT (same type, longest bay 3.07 m).

Pick Layher Blitz if…

  • you want long bays: Layher Blitz reaches 3.07 m, where the longest bay of most other systems of its type in ScaFix is 3 m.
  • you need a wide working deck: ScaFix plans Layher Blitz up to 1.09 m deep, where most systems of its type stop at 0.73 m.
  • you want fewer pieces to handle: Layher Blitz needs 263 parts on ScaFix’s example house, against a median of 333 for its type.

Layher Blitz on a block of flats

ScaFix counts 382 parts when a 30 × 12 m façade is scaffolded in Layher Blitz, and 1120 when the same is done round a whole four-storey block: two such façades and two 12 × 12 m gables, with the corners not joined.

The example is worked through, with a way to price it, in scaffolding for a block of flats.