Skip to content

Scaffold parts

Scaffold tubes and poles: sizes, weights and lengths

Scaffold tube, scaffold pole and standard often mean the same thing: the 48.3 mm steel tube that carries the scaffold. EN 39 sets 48.3 mm outside diameter with a 3.2 or 4.0 mm wall, about 4.37 kg per metre for the thicker one; the US nominal 2 in tube is also 1.90 in.

This page gives the size the European standard fixes and its US equivalent, what a metre of tube weighs, how long poles and system standards come, and how many standards, ledgers and transoms ScaFix counts for one wall 10 m long and 6 m high.

· How the numbers are computed ·

Close-up of the corner where the long wall and the gable wall meet, with Layher Allround standards, decks, guardrails and toe boards in the ScaFix 3D model
The corner: the bays of the two walls meet, with deck, guardrail and toe board on each lift.

What size is scaffold tube?

Scaffold tube is 48.3 mm in outside diameter. EN 39 specifies loose steel tube for tube and coupler scaffolding at 48.3 mm with a 3.2 mm or 4.0 mm wall, which weighs about 3.56 kg or 4.37 kg per metre. The US 'nominal 2-inch' tube has the same 1.90-inch outside diameter; a common long pole is 21 ft (6.4 m).

Tube sizes in Europe, the UK and the US

TubeOutside diameterWallWeight per metre (calculated)Where the size comes from
Steel tube to EN 3948.3 mm3.2 mm3.56 kgEN 39:2001 scope
Steel tube to EN 3948.3 mm4.0 mm4.37 kgEN 39:2001 scope
Aluminium tube48.3 mm4.0 mm1.50 kgBG BAU Baustein B 117 (as guardrail tube)
US steel tube or pipe, «nominal 2 in.»1.90 in (48.3 mm)not given–OSHA Subpart L, Appendix A
US heavy-duty bearer, «nominal 2½ in.»2.375 in (60.3 mm)not given–OSHA Subpart L, Appendix A

The weights are calculated from the cross-section with steel at 7,850 kg/m³ and aluminium at 2,700 kg/m³, so treat them as close estimates; a supplier's figure for its own tube wins. A 3.2 mm and a 4.0 mm tube look alike on site, but the thinner one has about 19 % less steel in it, which is why a design such as a TG20:21 compliance sheet names the tube it assumes. Ask your supplier which edition of EN 39 its tube is certified to; listings differ between countries.

System parts are a different matter. Their tubes keep the 48.3 mm outside diameter so couplers still fit, but not always the wall: the German approval of the Layher Blitz Gerüst 70 Stahl (DIBt Z-8.1-16.2, 2 January 2025) names scaffold tubes of 48.3 × 2.9 mm and 48.3 × 2.7 mm in the high-strength steel S460MH, checked against raised requirements beyond EN 10219-1. A thin-walled system tube is therefore no substitute for loose EN 39 tube in a tube-and-fitting design.

Loose tube is sold in lengths up to 21 ft, about 6.4 m (a 21 ft scaffold tube listing), and cut down to shorter pieces for transoms, end rails and braces.

Poles, standards, ledgers and transoms: one tube, five jobs

  • Standard (pole, upright; «post» in US rules): the vertical tube that carries the load down to the base plate.
  • Ledger (runner): the horizontal tube along the scaffold. OSHA 1926.452(b)(8) asks for runners interlocked into continuous lengths on straight runs and coupled to each post, and Appendix A keeps them at most 6 ft 6 in apart vertically.
  • Transom (bearer): the short tube across the scaffold that carries the boards. Under 1926.452(b)(5) a bearer coupled to the posts has its inboard coupler bearing directly on the runner coupler, and (b)(6) wants it to reach past the posts and runners.
  • Putlog: a transom with one end resting in the wall's brickwork, on a putlog scaffold; the independent or putlog guide sets the two side by side.
  • Brace: a tube set diagonally with swivel couplers so the scaffold cannot rack. On straight runs OSHA 1926.452(b)(3) asks for longitudinal bracing at about 45 degrees from the base of the end posts to the top.

On a system scaffold the same jobs are done by purpose-made parts: standards with rosettes or cups at fixed intervals, ledgers and transoms with wedge heads in fixed lengths. Loose tube still turns up there, as guardrails at corners, as tie tubes and as bracing where the system parts do not reach.

System standards and ledgers: lengths and weights

On a modular scaffold the standard is a tube with a connector welded on at fixed intervals, sold in set lengths. Layher prints the mass of each for its Allround standards and ledgers (catalogue 2021/2022, Edition 04.2021):

Standard, steel (p. 13)WeightO-ledger LW (p. 17)Weight
1.00 m5.5 kg0.73 m2.9 kg
1.50 m7.8 kg1.09 m4.0 kg
2.00 m10.1 kg1.40 m5.0 kg
2.50 m12.4 kg2.07 m7.0 kg
3.00 m14.6 kg2.57 m8.5 kg
4.00 m19.2 kg3.07 m10.1 kg

A ledger is as long as the bay, so a system's bay lengths are also its ledger lengths. A 3.07 m ledger weighs 10.1 kg and a 2.00 m standard 10.1 kg; the standards run from 1.00 m to 4.00 m, so a tall scaffold is built from several standards joined on their spigots.

How many tubes does a 10 m wall take?

In Layher Allround a 10 m by 6 m wall takes 24 standards, 18 ledgers and 12 transoms; other systems differ with their bay lengths. ScaFix plans the same straight wall in five systems, from rosette and cup systems to tube and coupler; the table gives the tube rows of each parts list:

SystemBays on the wallDecked levelsStandards, ledgers, transoms and braces
Layher Allround3 × 3.07 m2.5 m, 4.5 mStandards 2 m: 16; Standards 1 m: 8; Ledgers 3.07 m: 18; Transoms: 12; Diagonals 3.07 m: 2
HAKI Universal3 × 3.05 m2.57 m, 4.57 mStandards 2 m: 16; Standards 1 m: 8; Ledgers 3.05 m: 18; Transoms: 12; Diagonals 3.05 m: 4; Diagonals 3.2 m: 2
PERI UP4 × 2.5 m2.6 m, 4.6 mStandards 2 m: 20; Standards 1 m: 10; Ledgers 2.5 m: 24; Transoms: 15; Diagonals 2.5 m: 2
Cuplock4 × 2.5 m2.6 m, 4.6 mStandards 2 m: 20; Standards 1 m: 10; Ledgers 2.5 m: 24; Transoms: 15; Diagonals 2.5 m: 4
Tube & coupler5 × 2 m2.6 m, 4.6 mStandards 2 m: 24; Standards 1 m: 12; Ledgers 2 m: 30; Transoms: 18; Diagonals 2 m: 4

The tube-and-coupler row is ScaFix's general rule for that scaffold type, in 2.0 m bays. For a UK scaffold built to a TG20:21 compliance sheet, the tube-and-fitting quantities guide counts every tube by length and every coupler by type for a wall of the same length. The scaffolding calculator gives bays and lifts for your own walls.

Questions and answers

How long is a scaffold pole?

Loose tube comes in lengths up to 21 ft, about 6.4 m, and is cut to shorter pieces for transoms and braces. System standards come in set lengths instead: Layher's Allround steel standards run from 1.00 m to 4.00 m, and a 2.00 m standard weighs 10.1 kg.

How much does a scaffold tube weigh?

About 4.37 kg per metre for a 48.3 × 4.0 mm steel tube and 3.56 kg for the 3.2 mm wall, calculated from the cross-section. A 21 ft (6.4 m) tube with the 4.0 mm wall is therefore about 28.0 kg. Aluminium tube of the same size weighs about 1.50 kg per metre.

What is the difference between a scaffold pole and a standard?

None in the material: both are the vertical tube. «Pole» is the everyday word on UK yards, «standard» the word on drawings, and US rules say «post» or «upright». A horizontal tube along the scaffold is a ledger, one across it a transom.

Steel or aluminium scaffold tube?

Choose steel tube for a tube-and-coupler design and aluminium only where a design or rule names it. Aluminium tube of the same 48.3 mm size weighs about 34 % of steel tube with the same 4.0 mm wall, but it is less stiff, so it cannot simply replace steel in a design.

BG BAU accepts 48.3 × 4 mm aluminium tube, like 48.3 × 3.2 mm steel tube, as guardrail and mid-rail on trestle scaffolds with posts up to 3.00 m apart.

Do US scaffolds use the same tube?

Yes for posts, runners and braces: OSHA's Appendix A to Subpart L names nominal 2 in. (1.90 in outside diameter) steel tube or pipe for all three duty classes, and 2½ in. (2.375 in) bearers for heavy duty. Tube-and-coupler scaffolds over 125 ft must be designed by a registered professional engineer (1926.452(b)(10)).

Sources

Limits

  • The number of wall ties follows the system's tie rule. Their positions must be checked against the manufacturer's assembly instructions.
  • Round corners, silos and hanging scaffolds are in Pro. A round scaffold is not a standard configuration and needs a calculation or the supplier's documentation. A hanging scaffold (Layher Allround and HAKI Universal) always needs a structural calculation from the supplier or an engineer.