Skip to content

Scaffold parts

Scaffold brackets and consoles: sizes, uses and rules

A bracket, called a console in much of Europe, is a short cantilever hooked or clamped onto a standard or frame to carry boards outside the scaffold's own width. Most are fitted on the inside, to close the gap to the wall; others widen the top lift at the eaves or carry a protective roof over a pavement.

Below are the bracket lengths one approved system lists, the gap rules that decide where brackets go, and the roof-edge brackets ScaFix counts for one wall 10 m long.

· How the numbers are computed ·

Layher Blitz scaffolding around a house of 11.4 × 5.3 m with a gabled roof (eaves 4.5 m, ridge 6 m), drawn by the ScaFix 3D model
Layher Blitz around the example house, as ScaFix draws it in 3D.

What is a scaffold bracket used for?

A scaffold bracket, or console, extends the working platform beyond the scaffold's width. Inside brackets close the gap between the deck and the wall, which many rules cap at 0.30 m; outside brackets widen the top lift or carry roof-edge protection and fans. The Layher Blitz approval lists brackets from 0.22 to 1.30 m long.

Bracket lengths in an approved system

The German approval of the Layher Blitz Gerüst 70 Stahl (DIBt Z-8.1-16.2 of 2 January 2025, valid to 4 January 2030) lists these brackets among the system's parts (Table 1, Annex A pp. 52–71):

Bracket (as the approval names it)Length
Bracket 0.22 m without tube connector0.22 m
Bracket 0.36 m0.36 m
Bracket 0.50 m0.5 m
Bracket 0.73 m (also reinforced and swivelling)0.73 m
Bracket 1.09 m1.09 m
Eaves bracket 1.00 × 0.73 m1 m
Protective-roof bracket 1.30 m1.3 m

The same approval shows how they are meant to be used. Its regular configuration has two bracket variants: KK1 adds 0.36 m brackets on the inside of the scaffold at every level, and KK2 adds 0.73 m brackets on the outside at the top level as well. Access hatches may not be built into brackets, the narrow 0.19 m decks may only be used as filler decks with brackets or on a protective roof, and on a roof catch scaffold the screen posts go straight onto the frames or onto the 0.73 m widening brackets, secured with drop-in pins.

The gap to the wall decides the inside bracket

A scaffold rarely stands tight to the wall: base jacks, plinths, sills and render need room. Where the gap between the deck and the wall is larger than the local rule allows, an inside bracket with boards or an inside guardrail closes it:

CountryGreatest gap from deck to wallRule
Norway0.30 mForskrift om utførelse av arbeid § 17-14
Germany0.30 mTRBS 2121-1, 4.2.1 and 4.3.1
Sweden0.30 m, normallyAFS 2023:11, chapter 8, section 10
Denmark0.3 m where the guardrail on the wall side is left outBEK 428 § 94
France20 cmCode du travail R4323-78
Netherlands15 cm, on the handover checklistVolandis A-blad Steigerbouwen
Polandover 0.2 m: a guardrail on the wall sideDz.U. 2003 nr 47 poz. 401, § 115(4)
United States14 in (36 cm) from the face of the work, with exceptions29 CFR 1926.451(b)(3)
United Kingdomno figure in law; 225 mm is the working figure in NASC guidanceWork at Height Regulations 2005, Schedule 3

The sources and exceptions for each country are in how far a scaffold may stand from the wall. On a tube-and-fitting scaffold the inside bracket is the hop-up bracket, clamped to the standard and carrying one or two boards; the tube-and-fitting quantities guide notes that inside boards on brackets add boards and fittings on the building side.

Bracket scaffolds hung from the wall

A bracket scaffold without standards, hung from the structure itself, is a different thing. BG BAU calls it a scaffold «of an older type» and treats it only as an exception (Baustein B 119, 07/2021). Its rules give a feel for what a bracket carries:

  • A proof of usability is required, by structural calculation, type test or approval, on the basis of EN 12811-1, and the bracket maker's instructions apply to the hanging points.
  • As a working scaffold for at most 2.0 kN/m², with brackets at most 1.50 m apart, a cantilever of at most 1.30 m and corner brackets at building corners.
  • Hooks at least 25 cm long or secured against unhooking, and two hanging loops per bracket.
  • Boards overlapping by at least 20 cm over the brackets, a toe board at least 15 cm above the deck and 3 cm thick, and side protection at the ends too.

In the United States, 29 CFR 1926.452(g) says how carpenters' and form brackets are attached (nails, a metal stud device, welding, hooking over a secured member, or a through-bolt for carpenters' brackets), with folding metal brackets bolted or pinned when open, and 1926.452(h) asks roof brackets to fit the roof pitch and give a level platform, anchored by nails or by rope of at least ¾ in diameter.

Roof-edge brackets on a 10 m wall

Brackets also carry the side protection at a roof edge. ScaFix adds those rows to the parts list when roof-edge protection is switched on for a wall; here for the same wall, 10 m long and 6 m high, with a 30° roof:

SystemBays on the wallDecked levelsRoof-edge rows in the parts list
Layher Blitz3 × 3.07 m0.71 m, 2.71 m, 4.71 mRoof-edge posts: 4; Solid metal roof-edge panels 3.07 m: 3; Roof-edge cantilever brackets: 4
Layher Allround3 × 3.07 m2.5 m, 4.5 mRoof-edge posts: 4; A2 safety-net panels 3.07 m: 3; Roof-edge cantilever brackets: 4
HAKI Universal3 × 3.05 m2.57 m, 4.57 mRoof-edge posts: 4; Solid metal roof-edge panels 3.05 m: 3; Roof-edge cantilever brackets: 4
Plettac SL 70/1004 × 2.5 m2.5 m, 4.5 mRoof-edge posts: 5; Solid metal roof-edge panels 2.5 m: 4; Roof-edge cantilever brackets: 5
PERI UP4 × 2.5 m2.6 m, 4.6 mRoof-edge posts: 5; A2 safety-net panels 2.5 m: 4; Roof-edge cantilever brackets: 5

Layher Blitz takes 4 cantilever brackets on the three bays, Plettac SL 5 on its four, because the brackets follow the frame lines. The panels follow the bays, so their count rises with every extra bay rather than with every frame line.

Questions and answers

What is a hop-up bracket?

A hop-up bracket is the UK name for a short bracket clamped to a standard on the inside of a tube-and-fitting scaffold, carrying one or two boards closer to the wall. It is how such a scaffold closes the gap to the face where the main platform cannot stand closer.

How far can a scaffold bracket stick out?

As far as its approval allows. The Layher Blitz approval lists brackets of 0.22, 0.36, 0.50, 0.73 and 1.09 m and a 1.30 m protective-roof bracket. For bracket scaffolds hung from a wall, BG BAU caps the cantilever at 1.30 m and the spacing of the brackets at 1.50 m.

Can an access hatch go on a bracket?

Not in the Layher Blitz regular configuration: its approval (DIBt Z-8.1-16.2) says access hatches may not be built into brackets. Keep the ladder bay on the scaffold's own decks and use the brackets for boards beside it, such as the 0.36 m inside brackets that configuration KK1 adds at every level.

What load can a bracket platform take?

At most 2.0 kN/m² for a wall-hung bracket scaffold of the older type used as a working scaffold, under BG BAU Baustein B 119, with brackets at most 1.50 m apart and a cantilever of at most 1.30 m. Brackets on a system scaffold follow the configuration in the manufacturer's approval, such as KK1 and KK2 for Layher Blitz.

Does ScaFix count brackets?

Yes, at roof edges: switch roof-edge protection on for a wall and the parts list gets roof-edge posts, panels and cantilever brackets, 4 brackets on the 10 m wall with Layher Blitz. The 3D model shows them on the top lift.

Sources

Limits

  • The number of wall ties follows the system's tie rule. Their positions must be checked against the manufacturer's assembly instructions.
  • Round corners, silos and hanging scaffolds are in Pro. A round scaffold is not a standard configuration and needs a calculation or the supplier's documentation. A hanging scaffold (Layher Allround and HAKI Universal) always needs a structural calculation from the supplier or an engineer.