Short answer
How far apart are scaffold standards?
Along the wall, the standards stand one bay length apart: 3.07 m on Layher Blitz and Allround, 3.05 m on HAKI Universal and 3 m on 41 systems in ScaFix's catalogue, with shorter bays to close a wall. Across, they stand one system width apart, often 0.7 to 1.1 m. A heavier load class can call for shorter bays.
One bay length apart along the wall and one system width apart across it. In ScaFix's catalogue the longest bay is 3.07 m, the load class can shorten it, and the tables below give the spacings for every system family.
By Ole Emil Frikstad Urstad · How the numbers are computed ·

Which bay lengths do scaffold systems use?
Each system sells its ledgers, decks and braces in a few fixed lengths, so the standards can only stand at those spacings. In ScaFix's catalogue of 115 systems, 95 offer a longest bay of 3 m or more, 3 m being the most common, and 20 stop below 2.6 m.
| System | Bay lengths in the catalogue (standards apart, along the wall) | Widths (standards apart, across) |
|---|---|---|
| Layher Blitz | 3.07 m, 2.57 m, 2.07 m, 1.57 m | 0.73 m, 1.09 m |
| Layher Allround | 3.07 m, 2.57 m | 0.73 m, 1.09 m, 1.4 m |
| HAKI Universal | 3.05 m, 2.5 m | 0.7 m, 0.77 m, 1.01 m, 1.25 m, 1.655 m |
| PERI UP | 3 m, 2.5 m, 2.25 m, 2 m, 1.75 m, 1.5 m, 1.25 m, 1 m, 0.75 m | 0.75 m, 1 m |
| Plettac SL 70/100 | 3 m, 2.5 m, 2 m, 1.5 m | 0.73 m |
| Cuplock | 3 m, 2.5 m, 1.8 m, 1.3 m, 1.25 m | 1.3 m |
| Kwikstage | 3.05 m, 2.44 m, 1.83 m, 1.27 m, 0.81 m, 0.762 m | 0.762 m, 1.27 m |
| Tube & fitting | 2.4 m, 2 m, 1.5 m, 1.2 m, 1 m | 0.73 m, 1.09 m, 1.4 m |
| Waco Frame (USA) | 3.048 m, 2.134 m, 1.524 m | 0.914 m, 1.524 m |
| Safway Systems Scaffold (USA) | 3.048 m, 2.743 m, 2.438 m, 2.134 m, 1.829 m | 0.914 m, 1.219 m, 1.524 m |
The lengths are the ones in ScaFix's catalogue, the same the 3D model and the parts list use; the methodology page explains where each system's data comes from. US systems are listed in metres converted from their nominal feet (3.048 m is 10 ft). Over all systems the bays run from 0.7 m to 3.07 m. Grouped by family:
| Family | Systems | Longest bay | Bay lengths per system (average) |
|---|---|---|---|
| Frame (facade) systems | 64 | 1.58 m to 3.07 m | 4 |
| Ringlock (rosette) systems | 33 | 1.8 m to 3.07 m | 6.2 |
| Wedge systems (Kwikstage type) | 7 | 1.8 m to 3.05 m | 4.1 |
| Cuplock systems | 6 | 1.5 m to 3.05 m | 4.8 |
| Tube and fitting | 3 | 1.5 m to 2.4 m | 4 |
| Shoring towers | 2 | 2.5 m | 4.5 |
Modular systems (ringlock, cuplock, wedge) carry more lengths per system because their ledgers fit any pair of standards, while a frame system ties the width to the frame and offers only the deck lengths.
Why can a heavier load class need shorter bays?
Because the decks and ledgers carry less over a longer span. The approvals tie each bay length to a load class: in the plettac SL 100 approval, 3.00 m bays are valid up to load class 4, 2.50 m bays for class 5 and 2.00 m bays for class 6. Heavy masonry can need closer standards than painting.
The other approvals show the same pattern. The Layher Blitz 70 Steel approval Z-8.1-16.2 rates its 0.32 m U-steel deck at class 4 on a 3.07 m bay, class 5 on 2.57 m and class 6 on 2.07 m, and the PERI UP Easy approval Z-8.1-957 allows its steel deck in the modular build up to class 4 on a 3.0 m bay, class 5 on 2.5 m and class 6 on 2.0 m or less.
A deck rating is not the whole scaffold's class: the same Blitz approval describes its standard configuration with bays of at most 3.07 m for load class 3. The load classes guide explains the classes and what they carry.

How far apart are the standards across the scaffold?
One system width, the distance between the inner and the outer standard. Frame systems usually have one or two widths, such as 0.73 and 1.09 m for Layher Blitz, while modular systems offer several, up to 1.655 m for HAKI Universal. The width class follows from the deck width: W06 means 0.6 to under 0.9 m.
The classes come from EN 12811-1 and run in steps of 0.3 m: after W06, W09 is 0.9 to under 1.2 m, and so on up to W24, as Baunetz Wissen summarises them. The same source gives the headroom classes for the clear height between lifts; the lift height guide covers those. A wider scaffold carries more boards: the boards per bay guide counts them for each width.
How are standards set out along a wall?
Fill the wall with as few bays as fit, longest first, and close the remainder with a shorter bay so the scaffold ends just past the wall. On a 13.5 m wall with all four Layher Blitz lengths, ScaFix's bay composer lays 5 bays, so each row has 6 standards.
The Blitz bays are 3.07 m + 3.07 m + 2.57 m + 2.57 m + 2.57 m; the table sets them beside two other systems on the same wall:
| System | Bays on a 13.5 m wall | Standards per row | Scaffold length |
|---|---|---|---|
| Layher Blitz (all four lengths) | 3.07 m + 3.07 m + 2.57 m + 2.57 m + 2.57 m | 6 | 13.85 m |
| HAKI Universal (2.5 and 3.05 m) | 3.05 m + 3.05 m + 2.5 m + 2.5 m + 2.5 m | 6 | 13.6 m |
| PERI UP | 3 m + 3 m + 2.5 m + 2.5 m + 2.5 m | 6 | 13.5 m |
The count of standards is always one more than the bays in a straight run, on the inner and the outer row. Corners and returns change it, because a corner bay shares standards with the wall it meets; the corners guide shows how. Where a wall has a door, a tree or a narrow side path, a shorter bay at that point keeps the standards clear of it.
Are the bay lengths the same across manufacturers?
No, only partly. Many ringlock systems in the catalogue share the 3.07, 2.57, 2.07 and 1.57 m series, and many frame systems use 3.0, 2.5 and 2.0 m. US systems are built in feet, with bays such as 10, 8 and 7 ft. A shared length does not mean the parts of two makers fit together.
The instructions for assembly and use, such as Layher's Allround instructions, describe one system as a set. Finland's decree 205/2009 says it outright: parts of different system scaffolds may be used together only if they can be connected safely (§ 61). ScaFix plans each wall in one system and lists the parts in that system's own lengths.
Planning information, not structural approval. Bay lengths, widths and load classes come from the system's instructions for assembly and use or approval, and a competent person inspects the scaffold before use.
Frequently asked questions
What is the maximum bay length of a scaffold?
In ScaFix's catalogue, 3.07 m, the longest bay of systems such as Layher Blitz and Allround. The approval then limits it by load class: plettac SL 100 allows 3.00 m bays up to class 4 and 2.00 m for class 6.
How far apart are the inner and outer standards?
One system width, often 0.7 to 1.1 m on a facade scaffold: 0.73 or 1.09 m on Layher Blitz, for example. Mobile towers have their own frame sizes, set by the tower's instructions. Under EN 12811-1 the width class follows from the deck width: W06 means 0.6 to under 0.9 m.
How many standards does a scaffold need?
Two rows, with one more standard per row than bays in a straight run. A 13.5 m wall in Layher Blitz takes 5 bays, so 6 standards on the inner row and 6 on the outer. Corners and returns change the count, because a corner bay shares standards with the wall it meets.
Can you mix bay lengths on one scaffold?
Yes, within one system. A wall is usually filled with the longest bays and closed with a shorter one; the lengths must all come from the same system's catalogue. Where a wall has a door, a tree or a narrow side path, a shorter bay at that point keeps the standards clear of it.
Sources
Primary sources used for this article, with the date each was read.
- DIBt approval Z-8.1-16.2: Layher Blitz 70 Steel, issued 2 January 2025, Table 6 and standard configuration (pdf) (read 25 October 2026)
- DIBt approval Z-8.1-957: PERI UP Easy (pdf) (read 25 October 2026)
- DIBt approval Z-8.1-171: Fassadengerüst plettac SL 100 (11 March 2019), Annex B (pdf) (read 25 October 2026)
- Baunetz Wissen: Gerüstklassen (load, width and headroom classes of EN 12811-1) (read 25 October 2026)
- Layher Allround Scaffolding, Instructions for Assembly and Use, edition 04.2018 (pdf) (read 25 October 2026)
- Finlex: Valtioneuvoston asetus rakennustyön turvallisuudesta 205/2009, 61 § (parts of different systems) (read 24 October 2026)