Skip to content

Scaffold calculators

Kwikstage scaffold calculator

ScaFix counts 205 Kwikstage parts for a 12 × 8 m wall: 4 bays (3 × 3.05 m + 1 × 2.44 m), platforms on 2.6 m, 4.6 m and 6.6 m, 40 standards, 32 ledgers, 20 transoms and 7 ties. Type your own wall into the Kwikstage-preset form here; no account is needed.

· How the numbers are computed ·

Size a Kwikstage wall

Length and height in metres; a comma or a dot both work. Kwikstage is preselected, and Acrow QUICKSTAGE plus the rest of the catalogue are one click away in the system list.

Result

12 m × 8 m wall, Kwikstage

Bays
4 (3 × 3.05 m + 1 × 2.44 m)
Lifts
4
Decked levels
3 (2.6 m, 4.6 m and 6.6 m)
Scaffold area
88.1 m²

Lifts are counted from the ground lift to the guardrail lift at the top; the decks lie at the heights listed.

Drawing of the scaffold along the wall: bays, lifts and decks from the calculation

Build this wall in 3D

From the ScaFix engine for one straight wall on level ground. The itemised parts list, corners, several walls and the 3D model are in the ScaFix app. A planning aid, not a structural calculation or approval of the scaffold.

Is there a Kwikstage scaffold calculator?

Yes. Type a wall's length and height into ScaFix's Kwikstage form and it works out the bays, the number of lifts, which levels carry decks and the scaffold's face area, with no account. For 12 × 8 m that is 4 bays and 88 m²; ScaFix's 205-piece list for that wall follows below.

Kwikstage: the set-up behind the numbers

One straight elevation on flat ground: no returns, no hop-ups, no shade cloth. Standards stand 0.76 m apart across the scaffold, and access is by internal ladders through a hatch deck on every working lift. Lifts are 2 m, the limit Waco Kwikform sets between a new lift and the ledgers and transoms below it unless an engineer says otherwise (PPM51, p. 3); at 8 m the working platforms then sit on 2.6 m, 4.6 m and 6.6 m.

Waco Kwikform lists Kwikstage among its own modular systems; other suppliers stock Kwikstage components or sell a system of their own. ScaFix's Kwikstage ties and braces therefore follow one guide, Waco Kwikform's PPM51. In Acrow QUICKSTAGE (AU) the same 12 × 8 m wall becomes 3 × 3.05 m + 1 × 2.43 m, decked at 2.58 m, 4.56 m and 6.54 m: ScaFix gives QUICKSTAGE a 1.981 m lift, four of its 495 mm node spacings, and counts 191 parts for it in the app. Everything else on this page is Kwikstage.

Read this before ordering: PPM51's load figure of 6.6 kN per bay applies to bays no bigger than 1.27 m × 2.44 m (PPM51, p. 6). The engine uses 3.05 m ledgers where they fit the wall best, so get the 3.05 m bay rating from your supplier, or set 2.44 m bays in the app.

ScaFix parts list: Kwikstage on a 12 × 8 m wall

4 bays (3 × 3.05 m + 1 × 2.44 m), 11.59 m of scaffold, 88 m², platforms on 2.6 m, 4.6 m and 6.6 m. This list comes from the ScaFix app; the form above returns bays, lifts, decked levels and area only.

ScaFix parts list: Kwikstage on a 12 × 8 m wall
PartLengthCount
Frames and standards
Standards2 m30
Standards1 m10
Ledgers and beams
Ledgers3.05 m24
Ledgers2.44 m8
Transoms20
Decks
Decks without ladder3.05 m7
Decks without ladder2.44 m3
Decks with ladder3.05 m3
Guardrails
Front guardrails3.05 m24
Front guardrails2.44 m8
Toeboards
Toeboards3.05 m9
Toeboards2.44 m3
Diagonals
Diagonals3.05 m3
Diagonals2.44 m3
Diagonals0.76 m6
Ends
End guardrails6
Wall ties and fittings
Wall ties7
Wall-anchor fittings7
Right-angle couplers for wall ties14
Base jacks and legs
Base jacks / legs10

This is our example. The parts list for your own walls follows your measurements and settings.

Calculated with ScaFix, a scaffold planning app for browser and iPhone (115 scaffold systems from 57 manufacturers, checked 10 November 2026).

How is each Kwikstage count for 12 × 8 m worked out?

By multiplication from 4 bays, 5 standard lines and 3 working lifts. Standards, transoms and base jacks go with the lines; ledgers, decks, rails and toe boards go with the bays. That yields 40 standards, 32 ledgers, 20 transoms and 13 decks, and 205 pieces once braces, ties and jacks are in.

ItemQtyArithmetic
Standards (2 m + 1 m lengths)30 + 105 lines × 2 faces = 10 standard positions, each stacked from 3 × 2 m and 1 × 1 m; the 1 m length carries the top guardrail
Ledgers324 bays × 2 faces × 4 levels (base plus 3 working lifts)
Transoms205 lines × 4 levels; the decks bear on them
Decks (plain + ladder hatch)10 + 34 × 3 working lifts = 12, a hatch deck in each lift, and 1 more where the first ladder stands
Front guardrails32top rail and mid-rail: 2 × 4 bays × 4 rows, the bottom row included for stiffness
Toe boards124 bays × 3 working lifts
Braces12face: the two end bays × 3 lifts = 6 (on 4 bays the last end bay is also the third); ends: 2 × 3 = 6
End guardrails62 open ends × 3 working lifts
Ties + anchor fittings7 + 7rows at most 4 m apart (first ≤ 4 m), end standards plus every second standard, alternate rows staggered; a fitting per tie
Tie couplers142 per tie: inner and outer standard
Base jacks1010 standard positions

Sum of the rows: 205. For a whole house, corners and gables included, see the Kwikstage parts list for a two-storey house.

Which Kwikstage bays does a given wall get?

The mix of Kwikstage ledger lengths whose total lands nearest the wall: ScaFix tries 3.05 m, 2.44 m, 1.83 m, 1.27 m, 0.81 m and 0.76 m and keeps the closest run. 12 m gives 3 × 3.05 m + 1 × 2.44 m, 11.59 m long. Six other walls follow, each with the gap or overhang it leaves.

WallKwikstage baysGap or overhangScaffold length
5 m2 (2 × 2.44 m)0.12 m shorter4.88 m
7 m3 (2 × 2.44 m + 1 × 1.83 m)0.29 m shorter6.71 m
9 m3 (2 × 3.05 m + 1 × 2.44 m)0.46 m shorter8.54 m
11 m4 (2 × 3.05 m + 2 × 2.44 m)0.02 m shorter10.98 m
14 m5 (3 × 3.05 m + 2 × 2.44 m)0.03 m longer14.03 m
18 m6 (5 × 3.05 m + 1 × 2.44 m)0.31 m shorter17.69 m

At 9 m, for instance, the run is 2 × 3.05 m + 1 × 2.44 m, 0.46 m shorter than the building, which matters at a corner or a boundary. Bays can be swapped one by one in the app, where a house is drawn with all its walls. Any system's bay split on its own: bay length calculator.

Five more Kwikstage walls, smallest to largest

Five more Kwikstage walls, all counted by ScaFix with engine-picked bays at 0.76 m wide: 81 pieces at the small end, 557 at the large. A click on a wall loads it into the form.

WallBays usedWorking liftsFace areaStandardsLedgersTransomsTiesPiecesPieces/m²
8 × 4 m1 × 3.05 m + 2 × 2.44 m129 m²161283812.8
12 × 6 m3 × 3.05 m + 1 × 2.44 m265 m²30241571602.5
16 × 8 m2 × 3.05 m + 4 × 2.44 m3121 m²56482892882.4
20 × 10 m4 × 3.05 m + 3 × 2.44 m4187 m²807040154212.2
24 × 12 m7 × 3.05 m + 1 × 2.44 m5276 m²1089654165572.0

Why does the 12 × 8 m Kwikstage wall get its number of ties?

7 ties, because PPM51 sets the pattern for Kwikstage up to 20 m high: the end standards first, then gaps of no more than three standards, the lowest tie within 4.0 m of the base and at most 4.0 m between tie rows, staggered where possible. ScaFix ties more densely than that, at every second standard.

Per square metre of face, that is a tie every 12.6 m². PPM51 also wants each tube tie clamped to both the inner and the outer standard, hence two couplers a tie (PPM51, pp. 4–5). Past 20 m the end zones tie at every standard; past 30 m the guide calls for engineering advice. Shade cloth or sheeting changes the loads and needs its own design; the counts here are for an open scaffold.

Limits of a planning tool

ScaFix plans and counts; it does not design. There is no AS/NZS 1576 or AS 4576 compliance check here, and the supplier's guidance and a competent person's inspection still decide. The AS/NZS 1576 planning reference covers what sits on top in Australia: licences, duty classes, tie spacing and the 30-day inspection.

Limits

  • The number of wall ties follows the system's tie rule. Their positions must be checked against the manufacturer's assembly instructions.
  • Round corners, silos and hanging scaffolds are in Pro. A round scaffold is not a standard configuration and needs a calculation or the supplier's documentation. A hanging scaffold (Layher Allround and HAKI Universal) always needs a structural calculation from the supplier or an engineer.
Kwikstage scaffolding around a house of 11.4 × 5.3 m with a gabled roof (eaves 4.5 m, ridge 6 m), drawn by the ScaFix 3D model
Kwikstage around the example house, as ScaFix draws it in 3D.
Close-up of the top Kwikstage lift below the eaves, with guardrails and toe boards, in the ScaFix 3D model
The top lift below the eaves, with guardrails and toe boards.

Questions and answers

How many Kwikstage pieces go into a square metre of scaffold?

2.0 to 2.8 pieces per m² of face on the Kwikstage walls ScaFix counts on this page, the smallest 8 × 4 m and the largest 24 × 12 m. Bigger walls need fewer per m², because the ends, base row and ladder bay weigh less on them.

Can this form size Acrow QUICKSTAGE as well?

Yes. Kwikstage is only the starting choice; Acrow QUICKSTAGE and every other system in ScaFix's catalogue are in the list, and the result follows the chosen system's ledger lengths and lift. ScaFix gives QUICKSTAGE a 1.981 m lift. The worked figures on this page are all Kwikstage.

Does the Kwikstage form handle corners or a full house?

No, it takes one straight elevation, or one gable end if you tick the gable box and enter the ridge. Returns, a full outline, uneven ground and hop-up brackets belong in the ScaFix app, which lays out every elevation of the house with its corners and produces a single parts list for all of it.

Is a Kwikstage list from ScaFix an engineered design?

No. It is a planning count of what one supplier's standard set-up needs for the wall, not a structural calculation and not an AS/NZS 1576 compliance check. The supplier's guide sets how the scaffold goes up and is tied, and a competent person inspects it before it is used.

Sources

The tie rule behind the wall-tie counts on this page comes from these documents. ScaFix is a planning aid; the documents themselves, in their current edition, are what applies on site.