Skip to content

Guide

EN 12810 and EN 12811 explained: the European scaffold standards

Two standard families decide how most European facade scaffolds are designed and labelled. EN 12811 sets the rules for working scaffolds in general; EN 12810 is the product standard for system facade scaffolds built from prefabricated parts, intended for anchored use up to 24 m, with six load classes from 0.75 to 6.00 kN/m².

· How the numbers are computed ·

Plettac SL 70/100 scaffolding around a house of 11.4 × 5.3 m with a gabled roof (eaves 4.5 m, ridge 6 m), drawn by the ScaFix 3D model
Plettac SL 70/100 around the example house, as ScaFix draws it in 3D.

What are EN 12810 and EN 12811?

EN 12811 is the European standard for working scaffolds: part 1 sets performance requirements and design rules, part 2 covers materials, part 3 load testing and part 4 protection fans. EN 12810 is the product standard for prefabricated facade scaffold systems, intended for anchored use up to 24 m (DIN EN 12810-1); part 2 gives its structural design methods.

Before you rely on this guide

This guide summarises published rules to help you plan and is not legal advice. It has not been reviewed by a qualified scaffold designer or engineer. ScaFix is a planning aid, not structural approval: the manufacturer's instructions, the scaffold design and a competent person's inspection decide what is built and used on site. How these guides are written, sourced and corrected: editorial and review policy.

Which part of the standards covers what?

Six parts, in two families. EN 12811 is the general one and applies to working scaffolds of any kind, including tube and fitting. EN 12810 applies only to system facade scaffolds made of prefabricated components and builds on EN 12811. The German DIN editions below are the ones DIN Media lists as current.

StandardTitle (short)What it covers
EN 12811-1Scaffolds: performance requirements and general designLoads, load and width classes, side protection, access and the design of working scaffolds that rely on the building for stability; DIN edition 2004-03
EN 12811-2Information on materialsThe materials scaffold components are made of; DIN edition 2004-04
EN 12811-3Load testingHow components are tested, and how results are documented and evaluated; DIN edition 2003-02
EN 12811-4Protection fans for scaffoldsFans that catch objects falling from the scaffold edge, for falls from 24 m or less and impacts up to 720 J; EN 12811-4:2013
EN 12810-1Facade scaffolds of prefabricated components: product specificationsRequirements and proof of load-bearing capacity for system facade scaffolds, classification and designation; DIN edition 2004-03
EN 12810-2Particular methods of structural designCalculation and test rules for systems that conform to EN 12810-1

The rows follow the publishers' summaries: DIN Media for parts 12811-1 and 12810-1, Baunetz Wissen for 12811-2, DIN Media for 12811-3, EVS for 12811-4 and DIN Media for 12810-2.

How do EN 12810 and EN 12811 fit together?

EN 12811-1 is the base: it says what any working scaffold must do and how to prove it. EN 12810-1 applies those rules to one product group, the prefabricated facade system, and adds how such a system is classified and labelled. A frame or modular facade scaffold is therefore checked against both, while a tube-and-fitting scaffold follows EN 12811-1 alone.

DIN Media's notes show the history. DIN EN 12811-1 replaced DIN 4420-1:1990-12 and contains no rules for protective scaffolds, which stay in the national DIN 4420-1. DIN EN 12810-1 replaced DIN 4420-4:1988-12, and the European revision split it into two parts.

Layher Allround scaffolding around a house of 11.4 × 5.3 m with a gabled roof (eaves 4.5 m, ridge 6 m), drawn by the ScaFix 3D model
Layher Allround around the example house, as ScaFix draws it in 3D.

What does a scaffold designation under EN 12810-1 mean?

It is a short code for five criteria: load, width and headroom class, cladding and access. Baunetz Wissen's example «EN 12810 – 4 D – SW09/250 – H1 – B – LS» reads: load class 4, drop-tested platforms (D), system width 0.90 to under 1.20 m with 2.50 m bays, headroom H1, cladding (B), ladder and stair (LS).

The load class is the figure most people need on site. The six classes run from 0.75 kN/m² in class 1 to 6.00 kN/m² in class 6, as Norway's Producer Responsibility Regulations section 4-2 tabulate them, and classes 4 to 6 add a higher load on part of the bay. What each class allows is explained in scaffold load classes.

What does the 24 m in EN 12810-1 mean?

It is the height the standard's systems are intended for, not a legal ceiling. DIN Media's summary says the systems are intended for use up to 24 m, anchored to the facade. Above that, or outside the configurations a maker has proven, the scaffold needs its own structural calculation, for which EN 12810-2 gives the methods.

How tall scaffolds are handled country by country is in how high can scaffolding be.

Where do approvals and manuals come in?

On top of the standard, which sets the method. An approval or type certificate checks one system against it and fixes the configurations that may be built without further calculation. In Germany that is the DIBt approval: Plettac SL 70's Z-8.1-29 allows its regular configuration without further proof only when the bay loads stay within DIN EN 12811-1, Table 3.

The manufacturer's instructions for assembly and use then turn the approval into a building sequence, tie pattern and parts list. In practice the order of authority on site is: the national regulation, the system's approval or certificate, the manufacturer's instructions, and a design where the scaffold leaves them.

Which standards sit next to EN 12810 and EN 12811?

Several, each for a neighbouring product. Mobile towers follow EN 1004-1, in force as NS-EN 1004-1:2020 in Norway; support towers follow EN 12813; couplers follow EN 74 and loose scaffold tubes EN 39. Baunetz Wissen lists these with their German editions, some of which have since been revised.

StandardProduct
EN 1004-1Mobile access and working towers
EN 12813Support towers of prefabricated components
EN 74-1, -2, -3Couplers, special couplers, base plates and spigot pins
EN 39Loose steel tubes for tube and coupler scaffolds
DIN 4420-1 (national)Protective scaffolds such as catch scaffolds and roof catch scaffolds

What tube and board sizes do EN 39 and BS 2482 set?

EN 39:2001 covers non-alloy steel tubes for use with EN 74 couplers; its scope note names an outside diameter of 48.3 mm and a thickness of 3.2 mm or 4.0 mm. In Great Britain, BS 2482:2009 specifies timber scaffold boards 225 mm wide and 38 mm or 63 mm thick, each graded for a maximum support spacing.

StandardPublished valueSource
EN 39:2001, tubesOutside diameter 48.3 mm; thickness 3.2 mm or 4.0 mm; for EN 74 couplersSFS-EN 39:2001
BS 2482:2009, boardsWidth 225 mm; thickness 38 mm or 63 mmBS 2482:2009
BS 2482:2009, 38 mm boardOne grade for supports up to 1.2 m (visual or machine graded), one for up to 1.5 m (machine graded only)BS 2482:2009 scope
BS 2482:2009, 63 mm boardOne grade for supports up to 2.5 mBS 2482:2009 scope

Two dates matter. BSI lists BS EN 39:2001 as withdrawn on 21 May 2026, and DIN shows the EN 39 edition 2001-04 as withdrawn, with CEN/TC 459/SC 10 responsible (DIN); neither names a successor, so check the edition your supplier certifies. BS 2482:2009, published on 30 June 2009, does not cover laminated or finger-jointed boards. The spans of a whole platform, and the tie and brace rules, come from the TG20:21 compliance sheet or the system manual, not from the board standard.

How does ScaFix use the standards?

As the frame for the makers' rules, not as a replacement for them. ScaFix's engine takes bay lengths, deck widths and tie patterns from each system's instructions and approval, and names the source beside the number, as the methodology page explains. Where a system's documents are silent, the engine says so instead of inventing a figure.

Planning information, not structural approval. The standards are summarised from the publishers' descriptions; the binding wording is in the standards themselves, and a scaffold is built to its approval or instructions, or to a design, and inspected before use.

Frequently asked questions

Is BS EN 12811-1 still current in the UK?

Yes. BSI lists BS EN 12811-1:2003 as current (BSI published it on 16 June 2004). In the UK, NASC's TG20:21 for tube and fitting and TG30 for system scaffolds were developed in response to it, and they are what most scaffolds are actually checked against on site.

Is EN 12811-1 still current?

Yes. DIN Media lists DIN EN 12811-1:2004-03 as current, and it replaced the German DIN 4420-1:1990-12. In the UK, BSI likewise lists BS EN 12811-1:2003 as current. EN 12811-1 is the base standard for working scaffolds: it sets the loads, load and width classes, side protection and access that any working scaffold must meet.

What is the difference between EN 12810 and EN 12811?

EN 12811 is the general standard for working scaffolds of any kind, including tube and fitting, while EN 12810 is the product standard for system facade scaffolds built from prefabricated components and builds on EN 12811. A frame or modular facade scaffold is therefore checked against both standards; a tube-and-fitting scaffold follows EN 12811-1 alone.

Does EN 12810 limit scaffolds to 24 m?

No. EN 12810-1 is written for facade systems anchored to the building up to 24 m; DIN Media's summary calls that the intended height of use, and it is not a legal ceiling. Taller scaffolds, or configurations outside the ones the maker has proven, need their own structural calculation, and EN 12810-2 gives the methods for it.

Do protective scaffolds follow EN 12811?

No. DIN EN 12811-1 contains no rules for protective scaffolds such as catch scaffolds and roof catch scaffolds; in Germany these follow the national DIN 4420-1. DIN Media's notes record that DIN EN 12811-1 replaced DIN 4420-1:1990-12 and left protective scaffolds to the national standard.

Which standard covers mobile towers?

EN 1004-1 covers mobile access and working towers; in Norway it is published as NS-EN 1004-1:2020. The tower standard sits next to EN 12810 and EN 12811 as a separate product standard, just as support towers of prefabricated components follow EN 12813, couplers EN 74 and loose scaffold tubes EN 39.

What size is a scaffold tube under EN 39?

EN 39:2001 names an outside diameter of 48.3 mm and a thickness of 3.2 mm or 4.0 mm for steel tubes used with EN 74 couplers. BSI lists BS EN 39:2001 as withdrawn on 21 May 2026, and DIN shows the 2001-04 edition as withdrawn; neither names a successor, so check the edition your supplier certifies.

What sizes does BS 2482 give for scaffold boards?

BS 2482:2009 covers timber boards 225 mm wide and 38 mm or 63 mm thick. A 38 mm board is graded for supports up to 1.2 m or 1.5 m, a 63 mm board for supports up to 2.5 m.

Sources

Primary sources used for this article, with the date each was read.