ScaFix has 4 Layher systems: Layher Blitz, Layher Allround, Layher Blitz 70 Alu and Layher Allround STAR 70. On the same example house (11.4 m × 5.3 m), Layher Allround STAR 70 needs 272 parts and Layher Allround 515. All of them offer the 3.07 m, 2.57 m bay lengths.

Pair by pair: bay lengths and depths

Each pair of Layher systems, from the catalogue the engine plans with. «Only in» lists the bay lengths one system has and the other lacks; the last column is the parts total of each on the example house.

Layher systems compared head to head
PairTypeShared bay lengthsOnly in the firstOnly in the secondShared depthsParts on the house
Layher Blitz 70 Alu – Layher Allround STAR 70Same type: Frame3.07 m, 2.57 m, 2.07 m, 1.09 m, 0.73 m–1.57 m, 1.4 m0.73 m280 / 272
Layher Blitz – Layher Allround STAR 70Same type: Frame3.07 m, 2.57 m, 2.07 m, 1.57 m–1.4 m, 1.09 m, 0.73 m0.73 m308 / 272
Layher Blitz – Layher Blitz 70 AluSame type: Frame3.07 m, 2.57 m, 2.07 m1.57 m1.09 m, 0.73 m0.73 m308 / 280
Layher Blitz – Layher AllroundDifferent types: Frame / Ringlock (rosette)3.07 m, 2.57 m2.07 m, 1.57 m–1.09 m, 0.73 m308 / 515
Layher Allround – Layher Blitz 70 AluDifferent types: Ringlock (rosette) / Frame3.07 m, 2.57 m–2.07 m, 1.09 m, 0.73 m0.73 m515 / 280
Layher Allround – Layher Allround STAR 70Different types: Ringlock (rosette) / Frame3.07 m, 2.57 m–2.07 m, 1.57 m, 1.4 m, 1.09 m, 0.73 m0.73 m515 / 272

Parts group by group on the same house

Each Layher system planned on ScaFix’s example house (11.4 m × 5.3 m) with the default settings. The rows are the groups of the app’s parts list; «–» means the system has no part in that group. How the example is set up is on the methodology page.
Parts groupLayher BlitzLayher AllroundLayher Blitz 70 AluLayher Allround STAR 70
Frames and standards60966060
Decks36593232
Guardrails36725248
Toeboards36243232
Diagonals24888
Ends281688
Wall ties and fittings56564844
Base jacks and legs32644040
Ledgers and beams–120––
Bays on the long wall4455
Depth0.73 m0.73 m0.73 m0.73 m
All parts308515280272

Questions and answers

Can I mix parts from two Layher systems in ScaFix?

No. ScaFix plans each wall with one system’s own parts and never mixes systems in a parts list. Whether two systems of one maker may be combined on site is for Layher’s instructions to say. ScaFix is a planning aid, not a structural approval.

Why do the parts totals of the Layher systems differ?

A wall is filled with each system’s own bay lengths, so a shorter bay means more bays, standards and ledgers; the depth changes the transoms and decks, and frame systems count frames where modular systems count standards and ledgers. The totals say nothing about price or load class.