Skip to content

Guide · 11 of 24

How to read the ties ScaFix plans

The ties are in the parts list under Wall ties and fittings, and the note Wall ties (anchoring) explains the number: the rule, its source with the page and which numbers are DERIVED. X-ray shows the ties through the house and Colour-coded colours ties and braces. It is a starting point, not a tie plan for the site.

ScaFix Basic or Pro See the plans and what they cost

What you need

  • ScaFix Basic or Pro
  • A project with walls and a chosen system.

Step by step

  1. Step 1 Find the ties in the parts list

    Open Parts list. The family Wall ties and fittings shows the wall ties, fittings and couplers. Below the list is the note Wall ties (anchoring).

    The parts list with Wall ties and fittings and the tie note for HAKI Ram.
  2. Step 2 Read the note

    For the example it says that the list has 34 wall ties for HAKI Ram, 10 of them cross or V ties, one per started five tied standards per level (DERIVED), with the source: the manufacturer's assembly instructions and the page. DERIVED means the number is not printed in the manual; ScaFix worked it out from the manual with the formula stated in the note.

  3. Step 3 See the ties through the house

    Choose X-ray under View. The house turns transparent, so you see the scaffold and the ties on the wall side.

    X-ray view: the house transparent blue with the scaffold and the wall side visible.
  4. Step 4 See the part types in colour

    Choose Colour-coded. The legend at the bottom left includes Ties and Braces, so you can see where they are planned. In the example (HAKI Ram) ScaFix has planned no braces. A plan without braces does not mean the instructions need no bracing; check them.

    Colour-coded view with the legend: Standards and frames, Ledgers, Decks, Guardrails, Toe boards, Braces, Ties, Base jacks, Ladders and stairs and Other.

What the plan does not decide

The number follows the rule named in the note, with its source, for a standard scaffold. The wall it ties into, netting or sheeting, wind load and extras such as a hoist can call for more or different ties. Always check against the manufacturer's assembly instructions and the conditions on site, and let a competent person decide the tie plan.

Common mistakes

  • DERIVED read as the manufacturer's number. The number is not printed in the manual. ScaFix worked it out from the manual with the formula stated in the note; check it against the manual.
  • The total used for one wall. Choose the wall under Per wall to see that wall's number.
  • Netting or sheeting added without reviewing the ties. Cladding raises the wind load; review the ties again.