# Scaffold system specifications

> Bay lengths, depths, lift height and the wall-tie rule with its source for 115 scaffold systems from 57 makers. Table, CSV and JSON.

Canonical: https://scafix.app/scaffold-system-specs · Updated 2026-11-20

One row per scaffold system in the ScaFix catalogue: the bay lengths and depths it is planned with, the lift height the app erects it in, and the wall-tie rule the engine applies, with the document and page the rule comes from. Generated from the catalogue the app plans with, so a new system or a changed rule shows here on the next build.

### What are the bay lengths, depths and tie rules of each scaffold system?

ScaFix's catalogue holds 115 scaffold systems from 57 manufacturers. The most offered bay is 2.5 m (48 systems), the most offered depth 0.73 m (44), and 98 systems are erected in 2 m lifts. 91 of the 115 wall-tie rules cite a document and are checked against it; the other 24 show their spacings as «≈» estimates.

### The catalogue at a glance

Ranges over every system and the values most systems share, counted from the table below.

| Measure | Range | Most systems | Systems |
|---|---|---|---|
| Bay length | 0.7 m–3.07 m | 2.5 m | 48 |
| Depth | 0.6 m–1.66 m | 0.73 m | 44 |
| Main lift height | 1.52 m–2.13 m | 2 m | 98 |
| Tie rows, vertical | 1.73 m–9 m | 4 m | 99 |

| Source of the tie rule | Systems | Share |
|---|---|---|
| Manufacturer's document | 89 | 77% |
| Regulation | 12 | 10% |
| Third-party document | 6 | 5% |
| General rule (no document) | 8 | 7% |

### Every system: bays, depths, lift and wall-tie rule

115 rows, by maker. Bay lengths and depths are those of all the system's length variants; the tie rule is the one the engine applies to the system's main variant on an open (unclad) facade. «Estimate (≈)» marks a rule with no document, or one not yet checked against its document; [Verification status by scaffold system](https://scafix.app/systems/verification-status) gives each system's status and [Wall tie spacing by system](https://scafix.app/scaffolding-guides/wall-tie-spacing-by-system) each rule's page references.

Download every row in English, with the tie pattern in separate columns and the page references: [CSV](https://scafix.app/data/scaffold-system-specs.csv) or [JSON](https://scafix.app/data/scaffold-system-specs.json).

| System | Maker | Type | Bay lengths | Depths | Lift | Ties: vertical / along the face | Tie rule source | Status |
|---|---|---|---|---|---|---|---|---|
| [Acrow QUICKSTAGE (AU)](https://scafix.app/systems/acrow-quickstage) | Acrow | Modular, wedge | 0.76 m · 1.27 m · 1.82 m · 2.43 m · 3.05 m | 0.76 m · 1.27 m | 1.98 m | 4 m / Every 3rd standard, staggered rows | [Waco Kwikform «Kwikstage» guide PPM51 (08/2013) s. 5 (AS/NZS 1576.3 / 4576): up to 20 m ties at each end standard and at least every 3rd standard, vertically ≤ 4.0 m, staggered](https://www.wacokwikform.com.au/wp-content/uploads/Guidelines-Safe-Use.pdf) | Derived from the document |
| [Acrow SUPERCUPLOK (AU)](https://scafix.app/systems/acrow-supercuplok) | Acrow | Cuplock | 1.27 m · 1.83 m · 2.44 m · 3.05 m | 0.83 m · 1.27 m | 2 m | 4 m / Every standard | [Acrow «SUPERCUPLOK Technical Guide» (CUPLOK_OCT2026 issue J) s. 70–72 (PDF s. 71: ties commence where the height exceeds 3 × the least width](https://www.acrow.com.au/wp-content/uploads/2026/10/CUPLOK_OCT2026_ISSUE_J.pdf) | Derived from the document |
| [AFIXFAST (Rosette spigot)](https://scafix.app/systems/afixfast-x52) | AFIXFAST | Modular, rosette | 0.73 m · 1.04 m · 1.09 m · 1.4 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.22-1012 «AFIXFAST X52» (Afix Group NV, 04.12.2025) Anlage C §C.1 (PDF S. 63: 24 m), §C.5 (PDF S. 64: Schutzwand oberste Lage an jedem Ständer), Anlage D S.1 (PDF S. 67)](https://www.dibt.de/pdf_storage/2025/Z-8.22-1012%281.8.22-2%2120%29.pdf) | Derived from the document |
| [ALBERT BLITZFIX 70](https://scafix.app/systems/albert-blitzfix-70) | ALBERT | Frame | 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-885 ALBERT BLITZFIX 70 (12.07.2021, geänd. 23.08.2023, verl. 06.07.2026 bis 14.07.2031) Anlage B S. 5 §B.5 a–c (PDF S. 124: V-Halter nicht am Rand), Anlage C S. 1 (PDF S. 131: 1 V-Halter je 5 Felder), S. 13 (PDF S. 143: Schutzwand 2 V-Halter im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder)](https://www.dibt.de/pdf_storage/2021/Z-8.1-885%281.8.1-19%2121%29.pdf) | Derived from the document |
| [ALBERT UNITAC 70](https://scafix.app/systems/albert-unitac-70) | ALBERT | Frame | 1.5 m · 2 m · 2.5 m · 3 m | 0.74 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-979 ALBERT UNITAC 70 (02.04.2019, geänd. 19.03.2024 + 08.11.2024, bis 03.04.2029) Anlage B S. 3 §B.5 a–c (PDF S. 152), §B.10, Tab. B.5 (PDF S. 159: Netz 2 Dreieckhalter pro 5 Felder), Anlage C S. 1/2/3 (PDF S. 162–164: Dreieckhalter in jeder Ankerebene](https://www.dibt.de/pdf_storage/2019/Z-8.1-979%281.8.1-8%2118%29.pdf) | Derived from the document |
| [ALFIX ALBLITZ 70 S](https://scafix.app/systems/alfix-alblitz-70-s) | ALFIX | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every standard | [DIBt Z-8.1-864 ALBLITZ 70 S (16.01.2023, bis 11.01.2028) Anlage B S. 3–5 §B.5 (PDF S. 382–384: Dreieckshalter nicht an den außenliegenden Rahmenzügen](https://www.dibt.de/pdf_storage/2023/Z-8.1-864%281.8.1-59%2117%29.pdf) | Derived from the document |
| [ALFIX Facade](https://scafix.app/systems/alfix) | ALFIX | Frame | 2 m · 2.5 m · 3 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-862 ALFIX 70 (16.12.2020 bis 05.01.2027) Anl. B S. 7–8 §B.5 (PDF S. 179–180: V-Halter nicht an den Stirnseiten, Kopplungsrohre am Leitergang), Tab. B.4 (PDF S. 181), Anl. C S. 2 (PDF S. 185: 8 m versetzt, durchgehende Verankerung bei H = 4,0 m, mindestens 1 Dreieckshalter pro 5 Felder), S. 6 (PDF S. 189: Außenkonsole Dreieckshalter an jedem 2. Rahmenzug)](https://www.dibt.de/pdf_storage/2020/Z-8.1-862%281.8.1-33%2120%29.pdf) | Derived from the document |
| [ALFIX Modul](https://scafix.app/systems/alfix-modul) | ALFIX | Modular, rosette | 0.73 m · 1.09 m · 1.4 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m · 1.4 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.22-906 ALFIX Modul (15.10.2021, Bescheide 31.01.2023, 02.04.2025, verl. 12.10.2026 bis 16.10.2031) Anl. C s.1–2 §C.1/§C.5 (PDF s. 196–197), Anl. D s.1 (PDF s. 201: mindestens 1 Dreieckshalter je 5 Felder, Schutzwandlage 2 je 5 Felder)](https://www.dibt.de/pdf_storage/2021/Z-8.22-906%281.8.22-19%2117%29.pdf) | Derived from the document |
| [ALFIX UNIFIX 70](https://scafix.app/systems/alfix-unifix-70) | ALFIX | Frame | 1.5 m · 2 m · 2.5 m · 3 m | 0.74 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-847 UNIFIX 70 (21.12.2020, geänd. 04.04.2022, verl. bis 06.04.2027, geänd. 02.04.2025) Anlage B S. 8–9 §B.5 a–c (PDF S. 278–279: V-Halter nicht an den Stirnseiten), Anlage C S. 1 (PDF S. 284: mindestens 1 Dreieckshalter je 5 Felder, Schutzwandlage 2 je 5 Felder), S. 12 (Netz: 2 je 5 Felder) (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)](https://www.dibt.de/pdf_storage/2020/Z-8.1-847%281.8.1-34%2120%29.pdf) | Derived from the document |
| [ALTEC AluSprint](https://scafix.app/systems/altec-alusprint) | ALTEC | Frame | 2.5 m · 3 m | 0.65 m | 2 m | 4 m / Every standard | [ALTEC AluSprint AuV Regelausführung, Fassung 01.02.2010, §2.1 s.4 + §2.4.11 s.26 + Bild 17 s.24](https://altec-alu.de/sites/default/files/2022-08/aufbau_benutzungsanweisung_alusprint_2022.pdf) | From the document |
| [ALTRAD MAG 42](https://scafix.app/systems/altrad-mag-42) | ALTRAD | Frame | 3 m | 0.74 m | 2 m | 4 m / Every 2nd standard, staggered rows | [ALTRAD Saint Denis «Echafaudage MAG 42» fiche (ASD 11/2019](https://www.altrad-saint-denis.fr/images/pdf/ECHAFAUDAGE/ECHAFAUDAGES%20FIXES/ALTRAD/MAG%2042/echafaudage-altrad-mag-fiche-fr.pdf) | Derived from the document |
| [ALTRAD Baumann ProfiTech A 73 plus](https://scafix.app/systems/baumann-profitech-a73-plus) | ALTRAD Baumann | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-910 (19.12.2019, Bescheid 06.01.2026, verl. bis 13.01.2027) PROFITECH A 73 PLUS Anlage B S. 1 §B.1 (PDF S. 120: 24 m), S. 2 §B.5 a–c, Anlage C S. 1/8 (PDF S. 127/134: oberste Lage jeder Ständer, ② Zusatzanker in 4 m vor teilweise offener Fassade, Leitergang in jeder Ankerebene)](https://www.dibt.de/pdf_storage/2019/Z-8.1-910%281.8.1-49%2119%29.pdf) | Derived from the document |
| [ALTRAD Baumann ProfiTech S 73 plus](https://scafix.app/systems/baumann-profitech-s73-plus) | ALTRAD Baumann | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-912 ProfiTech S 73 plus (08.05.2018, Bescheid 22.05.2023, verl. bis 03.06.2028) Anlage B S. 1 §B.1 (PDF S. 181: 24 m), S. 3 §B.5 (PDF S. 183), Anlage C S. 1 (PDF S. 191), S. 5/6/7/11 (Leitergang in jeder Ankerebene)](https://www.dibt.de/pdf_storage/2018/Z-8.1-912%281.8.1-15%2118%29.pdf) | Derived from the document |
| [ALTRAD Baumann PROFITECH S 109](https://scafix.app/systems/baumann-profitech-s109) | ALTRAD Baumann | Frame | 0.73 m · 1.09 m · 1.4 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 1.09 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-909 PROFITECH S 109 (18.05.2021, verl. 02.01.2025 bis 08.01.2030) Anlage B S. 3 §B.5 (PDF S. 148: V-Anker nicht an den außenliegenden Rahmenzügen](https://www.dibt.de/pdf_storage/2021/Z-8.1-909%281.8.1-32%2121%29.pdf) | Derived from the document |
| [MOSTOSTAL Plus](https://scafix.app/systems/mostostal-plus) | Altrad Mostostal | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m | 2 m | 2 m / Every 2nd standard, staggered rows | [ALTRAD-Mostostal «MOSTOSTAL Plus frame scaffolding — assembly manual» (EN, 05.2023) §3.5.1 p. 20 (PDF 22), §3.5.5 basic option p. 22 (PDF 24)](https://altrad-mostostal.pl/wp-content/uploads/2023/05/altrad_mostostal_instrukcje_nowe_instrukcje_03_rusztowania_ramowe_anglia_nowa_szata.pdf) | Derived from the document |
| [ROTAX Plus (Modular)](https://scafix.app/systems/altrad-mostostal-rotax-plus) | Altrad Mostostal | Modular, rosette | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m | 2 m | 4 m / Every standard | [Altrad-Mostostal Instrukcja montażu ROTAX Plus 11.03.2026 §5 s. 32–34 (PDF 34–36) + RISE C900555 utg. 1 (2023-07-07, giltig t.o.m. 2033-07-07) vilkår 7–8](https://altrad-mostostal.pl/wp-content/uploads/2026/03/altrad_mostostal_instrukcje_nowe_instrukcje_02_rusztowania_rotax_polska_nowa_szata_a4_11_03_2026_compressed.pdf) | Derived from the document |
| [Aluhak (Facade)](https://scafix.app/systems/aluhak-fasade) | Aluhak | Frame | 0.72 m · 1 m · 1.2 m · 1.6 m · 1.9 m · 2.45 m · 3 m | 0.72 m | 2 m | 4 m / Every standard | [Aluhak MONTERINGSVEILEDNING Rammestillas alu. kl. 1-3, M-02-2025-R001-NO rev. 25.06.2025 s.16–17](https://www.aluhak.no/s/ALUHAK-Rammestillas-i-aluminium-klasse-1-3-REV-250625-Final.pdf) | Derived from the document |
| [Aluhak (Modular)](https://scafix.app/systems/aluhak-modul) | Aluhak | Modular, rosette | 0.72 m · 1 m · 1.2 m · 1.6 m · 1.9 m · 2.45 m · 3 m | 0.72 m · 1 m · 1.2 m · 1.6 m | 2 m | 4 m / Every standard | [Aluhak MONTERINGSVEILEDNING Systemstillas alu. kl. 1-6, M-01-2024-R001-NO rev. 18.12.2024 s.19–20](https://www.aluhak.no/s/M-01-2024-R001-NO-Systemstillas-i-aluminium-klasse-1-6-Sertifisert-brukerveiledning-frs9.pdf) | Derived from the document |
| [ANKA H-Tipi Cephe](https://scafix.app/systems/anka-h-tipi-cephe) | ANKA | Frame | 2.5 m | 0.73 m | 2 m | 6 m / Every standard | ANKA «Cephe İskelesi Mamul ve Talimat El Kitabı» (30.12.2016) s. 29, 36–43 (ankraj detayları LC 3 / LC 4, 24 m), 44 (not published online) | Derived from the document |
| [assco Futuro](https://scafix.app/systems/assco-futuro) | assco | Modular, rosette | 0.73 m · 1.09 m · 1.4 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m · 1.4 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.22-841 ASSCO FUTURO (23.1.2024) Anl. C §C.1, §C.5](https://www.dibt.de/pdf_storage/2024/Z-8.22-841%281.8.22-28%2120%29.pdf) | Derived from the document |
| [ASSCO QUADRO 70](https://scafix.app/systems/assco-quadro-70) | assco | Frame | 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-190 ASSCO QUADRO 70 (27.04.2018, Bescheid 02.05.2023, verl. bis 02.05.2028) Anlage B S. 3 §B.5 a–c (PDF S. 183), Anlage C S. 1 (PDF S. 191), S. 5/6/11](https://www.dibt.de/pdf_storage/2018/Z-8.1-190%281.8.1-4%2118%29.pdf) | Derived from the document |
| [AT-PAC Ringlock](https://scafix.app/systems/at-pac-ringlock) | AT-PAC | Modular, rosette | 0.73 m · 1.09 m · 1.4 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m · 1.4 m | 2 m | 4 m / Every 2nd standard, staggered rows | [Doka Ringlock User Information 999817902 (09/2023) s.74 + Appendix D s.75–76 (= DIBt Z-8.22-992): 8 m versetzt, V-anchor ≥ 1 per 5 bays, wall tie directly below the node, lowest anchor plane b = 4 m with hSP ≤ 29 cm (s.76)](https://direct.doka.com/_ext/downloads/downloadcenter/999817902_2023_09_online.pdf) | Derived from the document |
| [Bil-Jax Ring Lock](https://scafix.app/systems/bil-jax-ring-lock) | Bil-Jax | Modular, rosette | 0.91 m · 1.22 m · 1.52 m · 1.83 m · 2.13 m · 2.44 m · 3.05 m | 0.73 m · 1.09 m · 1.4 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | General rule (no document) | Estimate (≈): no manufacturer rule on file; follow the supplier's manual |
| [BrandSafway SafLock](https://scafix.app/systems/brandsafway-saflock) | BrandSafway | Modular, rosette | 1.15 m · 1.57 m · 2.13 m · 3.05 m | 1.15 m · 1.57 m | 2 m | 6 m / ≤ 6 m apart | BrandSafway «SafLock System Scaffold Technical Manual» ORN 2203 Rev. H (4/20) §3 p.57: first tie ≤ 3 × base width, ties at each end and ≤ 6 m along, ≤ 3 lifts vertically, the top within one lift, «all ties … as close to ledgers as possible» (not published online) | From the document |
| [Safway Systems Scaffold (USA)](https://scafix.app/systems/safway-systems-scaffold) | BrandSafway | Modular, rosette | 1.83 m · 2.13 m · 2.44 m · 2.74 m · 3.05 m | 0.91 m · 1.22 m · 1.52 m | 2.13 m | 6.1 m / ≤ 6 m apart | [BrandSafway «Systems™ Scaffold Product Selection Guide» ORN 210 Rev. F § I.8b/8c (p.19): first tie ≤ 4 × base (3'-0": 3.66 m), ≤ 20 ft (≤ 3 ft wide) / 26 ft vertical, ends + ≤ 30 ft along](https://brandsafway.com/uploads/files/orn210_bsl_systems_scaffold_product_selection_guide_1.pdf) | Derived from the document |
| Catari US Ringlock | Catari | Modular, rosette | 0.73 m · 1.04 m · 1.09 m · 1.4 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m · 1.4 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | General rule (no document) | Estimate (≈): no manufacturer rule on file; follow the supplier's manual |
| [CETA Multiceta](https://scafix.app/systems/ceta-multiceta) | CETA | Modular, rosette | 0.77 m · 1.1 m · 1.5 m · 2 m · 2.5 m | 0.77 m · 1.1 m | 2 m | 4 m / Every 2nd standard, staggered rows | [CETA «Manuale Ancoraggi» Rev.2 (10/2009) s. 3–4 «area d'influenza: massimo 22 m2 … non coperta da teli … 20 m»](https://www.ceta.it/documentazione/23/Manuale-Ancoraggi.pdf) | Derived from the document |
| [Condor (Facade)](https://scafix.app/systems/condor-tp105) | Condor | Frame | 1.8 m · 2.5 m | 1.05 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | [D.Lgs. 81/2008 art. 125 c. 6 «ancorato alla costruzione almeno in corrispondenza ad ogni due piani di ponteggio e ad ogni due montanti, con disposizione di ancoraggi a rombo o di pari efficacia»](https://www.normattiva.it/uri-res/N2Ls?urn:nir:stato:decreto.legislativo:2008-04-09;81) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [Condor (Modular/Ringlock)](https://scafix.app/systems/condor-multicom) | Condor | Modular, rosette | 0.75 m · 1.05 m · 1.5 m · 2 m · 2.5 m · 3 m | 0.75 m · 1.05 m | 2 m | 4 m / Every 2nd standard, staggered rows | [Condor MULTICOM, NF 096 certificate R25.03 (AFNOR, 01.12.2025, valid until 30.11.2026, no renewal published on 11.11.2026) annex s. 1/4 «Anchored in alternate rows all 24 m²»](https://www.condor-group.it/app/uploads/2020/01/R25.03-Certificat-CONDOR.pdf) | Derived from the document |
| Condor (Tube & coupler) | Condor | Tube and coupler | 1 m · 1.2 m · 1.5 m · 2 m · 2.4 m | 0.73 m · 1.09 m · 1.4 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | [D.Lgs. 81/2008 art. 125 c. 6 «ancorato alla costruzione almeno in corrispondenza ad ogni due piani di ponteggio e ad ogni due montanti, con disposizione di ancoraggi a rombo o di pari efficacia»](https://www.normattiva.it/uri-res/N2Ls?urn:nir:stato:decreto.legislativo:2008-04-09;81) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| DECKMAN (Facade) | DECKMAN | Frame | 2 m · 2.5 m · 3 m | 0.73 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | General rule (no document) | Estimate (≈): no manufacturer rule on file; follow the supplier's manual |
| [DELTA (Facade)](https://scafix.app/systems/delta-73) | DELTA | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | DELTA 73 DTR (Delta-Bud, Warszawa, wyd. 05.2020) §3.2.3 s. 57, §3.2.5 s. 58–59 «Podstawowe zasady wykonywania zakotwień» a–f, §6.2 s. 73, Wariant I s. 75 (not published online) | From the document |
| [DELTA (Modular/Wedge)](https://scafix.app/systems/delta-modul) | DELTA | Modular, rosette | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m | 2 m | 4 m / Every 2nd standard, staggered rows | DELTA MODUŁ Instrukcja montażu (Delta Rusztowania, Warszawa (not published online) | From the document |
| [Disk-lock Type B (China)](https://scafix.app/systems/disk-lock-type-b) | Disk-lock (CN) | Modular, rosette | 0.9 m · 1.2 m · 1.5 m · 1.8 m | 0.9 m · 1.2 m | 2 m | 4 m / Every 2nd standard, staggered rows | GB 55023-2022 §4.4.6 (≤ 3 跨 × 3 步 (not published online) | Derived from the document |
| [Doka Ringlock](https://scafix.app/systems/doka-ringlock) | Doka | Modular, rosette | 0.73 m · 1.09 m · 1.4 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m · 1.4 m | 2 m | 4 m / Every 2nd standard, staggered rows | [Doka Ringlock User Information 999817902 (09/2023) s.74 + Appendix D s.75–76 (= DIBt Z-8.22-992): 8 m versetzt, V-anchor ≥ 1 per 5 bays, wall tie directly below the node, lowest anchor plane b = 4 m with hSP ≤ 29 cm (s.76)](https://direct.doka.com/_ext/downloads/downloadcenter/999817902_2023_09_online.pdf) | Derived from the document |
| [Excel Modular Scaffold (USA)](https://scafix.app/systems/excel-modular-scaffold) | Excel | Cuplock | 1.22 m · 1.52 m · 1.83 m · 2.13 m · 2.44 m · 3.05 m | 0.61 m · 0.81 m · 1.07 m · 1.22 m | 2.04 m | 6.1 m / ≤ 6 m apart | [Excel Modular Scaffold «Standard Component Technical Manual» Rev. AL PDF p. 115 (printed p. 109, SIA Code of Safe Practices item 5): ties at each end and ≤ 30 ft along, ≤ 26 ft vertical, the top anchor no lower than 4 × the base dimension from the top](https://excelscaffold.com/wp-content/uploads/2024/03/Excel-tech-manual-Rev-AL-320.pdf) | Derived from the document |
| [FERMAR Fer48](https://scafix.app/systems/fermar-fer48) | FERMAR | Frame | 1 m · 1.5 m · 2 m · 2.5 m · 3 m | 0.7 m · 1.02 m | 2 m | 4 m / ≤ 6 m apart | [FERMAR «Andamio Europeo Fer48»: página web (leída 11.11.2026) § «Montaje» «La separación entre amarres será de 4 mtrs en altura y 6 en longitud» (primera fila ≤ 4 m: DERIVED)](https://www.fermar.es/productos/andamios-fermar/andamio-europeo-fer48/) | Derived from the document |
| [Fortal (Facade)](https://scafix.app/systems/fortal-fortec) | Fortal | Frame | 2 m · 2.5 m · 3 m | 0.65 m · 0.8 m | 2 m | 4 m / Every 2nd standard | [Fortal NT-054 V12 (FORTEC 650, 01.2023) §8 s. 12 «Tous les 24 m² maximum … non recouvert … en évitant d'avoir plus de 2 niveaux ou deux travées entre deux points d'ancrages consécutifs» (figure: every 2nd frame line every 2 levels), «ancrages fixés à l'intersection des montants avec les traverses»](https://www.fortal.fr/uploads/2023/01/NT-054-V-12-Echafaudage-ACIER-et-MIXTE-FORTEC-650.pdf) | Derived from the document |
| [HAKI Ram](https://scafix.app/systems/haki-ram) | HAKI | Frame | 1.66 m · 2.5 m · 3.05 m | 0.7 m | 2 m | 4 m / Every standard | [HAKI Monteringsveiledning Ram © HAKI AS 2023 06 (P000077) s. 26–27](https://www.haki.no/storage/7EB395EBCBD0268F8A29CDDB929F69F65C36E740A29D54589B835FB331D59882/4503ea282d304414848626294ab37622/pdf/media/2a784d88a27d4e35a57e2f385fd18cd4/Manual_HAKIRam_NO.pdf?forceDownload=true) | Derived from the document |
| [HAKI Universal](https://scafix.app/systems/haki-universal) | HAKI | Modular, wedge | 2.5 m · 3.05 m | 0.7 m · 0.77 m · 1.01 m · 1.25 m · 1.66 m | 2 m | 4 m / Every standard | [HAKI Monteringsveiledning HAKI Universal (NO) © HAKI AS 2022 10 Rev 5 (P000073) s. 30](https://api.haki.com/storage/media/891c12fc-c878-4217-911c-330920eb16ee/manual_haki_universal_international_en.pdf) | Derived from the document |
| [Hünnebeck BOSTA 70/100](https://scafix.app/systems/huennebeck-bosta) | Hünnebeck | Frame | 2 m · 2.5 m · 3 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-54.2 BOSTA 70 (16.06.2025, 07.05.2025 bis 07.05.2030) Anl. B §B.1 (PDF S. 176)/§B.5 (Ankerböcke nicht an den Stirnseiten, sonst einheitlich lange Gerüsthalter), Anl. C s.01/05/07](https://www.dibt.de/pdf_storage/2025/Z-8.1-54.2%281.8.1-21%2123%29.pdf) | Derived from the document |
| [Hünnebeck MODEX](https://scafix.app/systems/huennebeck-modex) | Hünnebeck | Modular, rosette | 0.74 m · 0.82 m · 1.13 m · 1.25 m · 1.5 m · 2 m · 2.5 m · 3 m | 0.82 m · 1.13 m | 2 m | 2 m / Every 2nd standard, staggered rows | [Hünnebeck MODEX User guide EN 2020 §9 Tab. 9.1, mønster 1/3 s. 113–117 (åpen fasade](https://products.huennebeck.com/fileadmin/redakteur/bilder/produkte/Scaffolding_systems/MODEX/EN_MODEX_user_manual.pdf) | Derived from the document |
| [Instant Blitz-Fix 73](https://scafix.app/systems/instant-blitz-fix-73) | Instant | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every standard | [RISE C901286 utg. 1 (2025-07-01) s. 3 pkt. 3 + s. 5 vilkår 5](https://cert.ri.se/en/products/C901286) | Derived from the document |
| [Jamax](https://scafix.app/systems/jamax) | Jamax | Frame | 2 m · 3 m | 0.68 m | 2 m | 4 m / Every standard | [Alutec «Brukerveiledning JAMAX stillassystemer» 4. utg. rev. 2 (28.08.2025) § 6.4.1 s. 16 Fordelingsmåte 1 (distribution method 1) + «Enkelt fag» (single bay)](https://www.jamax.no/content/uploads/2025/11/Brukerveiledning-JAMAX-stillassystemer-4.-utgave-rev.2-pr-28-08-2025.pdf) | Derived from the document |
| [JUMBO Facade](https://scafix.app/systems/jumbo) | JUMBO | Frame | 2 m · 2.5 m · 3 m | 0.73 m | 2 m | 2 m / Every 2nd standard, staggered rows | [JUMBO FLEX Montagevejledning JUMBO 2MM Facadestillads 3/2024 (DK) s. 6 §4.7.2 + figur 1 (forskudt ved hverandet knudepunkt), s. 2 (maks. byggehøjde 30 m)](https://www.epaper.dk/jumbo/manual/stilladser/facade_2mm_dk/) | Derived from the document |
| JUMBO System | JUMBO | Modular, rosette | 0.73 m · 1.04 m · 1.09 m · 1.4 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m · 1.4 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | General rule (no document) | Estimate (≈): no manufacturer rule on file; follow the supplier's manual |
| [KERO RHU 070](https://scafix.app/systems/kero-rhu-070) | KERO | Frame | 1.5 m · 2 m · 2.5 m · 3 m | 0.74 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-940 KERO RHU 070 (23.03.2023, bis 20.03.2028) Anlage B S. 3–4 §B.5 (PDF S. 216–217: jeder dritte Anker als Ankerbock, nicht an den Stirnseiten, sonst einheitlich lange Gerüsthalter), Anlage C S. 1/3/5 (PDF S. 223/225/227)](https://www.dibt.de/pdf_storage/2023/Z-8.1-940%281.8.1-11%2123%29.pdf) | Derived from the document |
| [KERO RK 073](https://scafix.app/systems/kero-rk-073) | KERO | Frame | 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-895 KERO RK 073 (06.02.2020, Bescheid 24.02.2025, bis 07.02.2030) Anlage B S. 4 §B.5 + Tab. B.2 (PDF S. 163), S. 7 (PDF S. 166), Anlage C S. 1 (PDF S. 173): «Gerüsthalter "lang"»](https://www.dibt.de/pdf_storage/2020/Z-8.1-895%281.8.1-67%2119%29.pdf) | Derived from the document |
| [KERO RPL 070](https://scafix.app/systems/kero-rpl-070) | KERO | Frame | 1.5 m · 2 m · 2.5 m · 3 m | 0.74 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-975 KERO RPL 070 (02.04.2019, verl. 19.03.2024 bis 03.04.2029) Anlage B S. 3 §B.5 a–c (PDF S. 138), §B.10, Tab. B.5 (PDF S. 145: Netz 2 Dreieckhalter pro 5 Felder), Anlage C S. 1/2/3 (PDF S. 148–150: L = 3,00 m in 4 m Höhe alle Knoten) (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)](https://www.dibt.de/pdf_storage/2019/Z-8.1-975%281.8.1-11%2118%29.pdf) | Derived from the document |
| [Layher Allround](https://scafix.app/systems/layher-allround) | Layher | Modular, rosette | 2.57 m · 3.07 m | 0.73 m · 1.09 m · 1.4 m | 2 m | 4 m / Every standard | [DIBt Z-8.22-64 (23.04.2018, forlenget 02.05.2027) Anl. C s.2 §C.5 Ausf. B + Anl. D s.3](https://www.dibt.de/pdf_storage/2018/Z-8.22-64%281.8.22-61%2117%29.pdf) | Derived from the document |
| [Layher Allround STAR 70](https://scafix.app/systems/layher-allround-star-70) | Layher | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-919 Layher Allround STAR 70 (07.11.2022, bis 02.11.2027) Anlage B S. 3 §B.5 (PDF S. 145: V-Anker nicht an den außenliegenden Rahmenzügen](https://www.dibt.de/pdf_storage/2022/Z-8.1-919%281.8.1-39%2122%29.pdf) | Derived from the document |
| [Layher Blitz](https://scafix.app/systems/layher-blitz) | Layher | Frame | 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m | 2 m | 4 m / Every standard | [DIBt Z-8.1-16.2 Anlage B s. 1 §B.1 + s. 4 §B.5 b](https://www.dibt.de/pdf_storage/2025/Z-8.1-16.2%281.8.1-49%2124%29.pdf) | Derived from the document |
| [Layher Blitz 70 Alu](https://scafix.app/systems/layher-blitz-70-alu) | Layher | Frame | 0.73 m · 1.09 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every standard | [DIBt Z-8.1-844 Layher Blitz Gerüst 70 Alu (20.04.2020, verl. bis 21.04.2030) Anlage B §B.1 (PDF S. 178), §B.5 a–b (PDF S. 180), Anlage C S. 1 (PDF S. 188)](https://www.dibt.de/pdf_storage/2020/Z-8.1-844%281.8.1-42%2115%29.pdf) | Derived from the document |
| [Metaltech Saferstack (USA)](https://scafix.app/systems/metaltech-saferstack) | Metaltech | Frame | 2.13 m · 2.44 m · 3.05 m | 0.91 m · 1.07 m · 1.52 m | 1.93 m | 4 m / ≤ 6 m apart | [Metaltech «Exterior Scaffolding Set Up Instructions / Safety Guidelines» (undated poster, PDF 22.04.2015) p. 1: 3 to 1 rule (tie above 3 × the smallest base dimension)](https://www.metaltech.co/wp-content/uploads/2021/07/METALTECH_Exterior_Scaffolding_Guidelines.pdf) | Derived from the document |
| [Metaltech Saferstack Mason (USA)](https://scafix.app/systems/metaltech-saferstack-mason) | Metaltech | Frame | 2.13 m · 2.44 m · 3.05 m | 0.61 m · 0.76 m · 1.22 m · 1.52 m | 1.52 m | 4 m / ≤ 6 m apart | [Metaltech «Exterior Scaffolding Set Up Instructions / Safety Guidelines» (undated poster, PDF 22.04.2015) p. 1: 3 to 1 rule (24" narrowest frame: 1.83 m)](https://www.metaltech.co/wp-content/uploads/2021/07/METALTECH_Exterior_Scaffolding_Guidelines.pdf) | Derived from the document |
| [MJ COMBI](https://scafix.app/systems/mj-combi) | MJ | Modular, rosette | 0.73 m · 1.04 m · 1.09 m · 1.4 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m · 1.4 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.22-921 MJ COMBI (13.10.2020, geänd. 05.09.2025, verl. bis 04.09.2030) Anlage C §C.1, §C.2, §C.5 (PDF S. 112–113: 8 m versetzt](https://www.dibt.de/pdf_storage/2020/Z-8.22-921%281.8.22-47%2120%29.pdf) | Derived from the document |
| [MJ OPTIMA](https://scafix.app/systems/mj-optima) | MJ | Modular, rosette | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.22-986 MJ OPTIMA (17.03.2021, Bescheide 13.06.2022, 17.04.2024, 06.07.2026, bis 23.07.2027) Anlage C S. 2 §C.5 (PDF S. 90: V-Halter nicht am Rand](https://www.dibt.de/pdf_storage/2021/Z-8.22-986%281.8.22-28%2119%29.pdf) | Derived from the document |
| [MJ UNI 70/100](https://scafix.app/systems/mj-uni-70-100) | MJ | Frame | 1.5 m · 2 m · 2.5 m · 3 m | 0.74 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-184 MJ UNI 70 (21.06.2019, verl. 06.07.2026 bis 13.07.2027) Anlage B S. 3 §B.5 a–c (PDF S. 94), §B.9, Anlage C S. 1 (PDF S. 98: langer Anker am Innen- und Außenständer, V-Anker), S. 3 (PDF S. 100: Schutzwand 2 V-Anker im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder), S. 8 (PDF S. 105: Netz, Randrahmen alle 2 m, 2 V-Anker im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder), S. 12 (PDF S. 109: L = 3,0 m, 4 m-Ebene alle Rahmen)](https://www.dibt.de/pdf_storage/2019/Z-8.1-184%281.8.1-34%2119%29.pdf) | Derived from the document |
| [MJ UNI TOP 65](https://scafix.app/systems/mj-uni-top-65) | MJ | Frame | 1.5 m · 2 m · 2.5 m · 3 m | 0.65 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-902 MJ UNI TOP 65 (11.08.2026, 18.08.2026 – 18.08.2031) Anlage B S. 3–4 §B.5 a–c (PDF S. 197–198: V-Halter nicht am Rand), §B.9 (PDF S. 200), Anlage C S. 1 (PDF S. 204: 1 V-Halter je 5 Felder), S. 4 (Netz: 2 V-Halter im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder), S. 7 (Schutzwand: 2 V-Halter im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder)](https://www.dibt.de/pdf_storage/2026/Z-8.1-902%281.8.1-18%2126%29.pdf) | Derived from the document |
| [MJ UNI-CONNECT](https://scafix.app/systems/mj-uni-connect) | MJ | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-872 MJ UNI-CONNECT 70 DUO (16.03.2022, Bescheid 10.06.2024) Anlage B S. 5 §B.5 a–c (PDF S. 403), Anlage C S. 1 (PDF S. 413: Fußnote 1 kurzer Gerüsthalter entfällt vor der geschlossenen Fassade, Rohr ø48,3 + NK innen unter den V-Haltern), S. 5/6 (PDF S. 417/418: Netz ohne Konsolen), S. 11 (Plane), S. 14 (PDF S. 426: Schutzwand, 2 V-Halter im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder)](https://www.dibt.de/pdf_storage/2022/Z-8.1-872%281.8.1-41%2115%29.pdf) | Derived from the document |
| [Müller & Baum FIX 70S](https://scafix.app/systems/mueller-baum-fix-70s) | Müller & Baum | Frame | 2 m · 2.5 m · 3 m | 0.74 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-182 Rahmengerüst FIX 70S (30.01.2020, verl. 21.01.2025 bis 31.01.2030) Anlage B S. 3 §B.5 a–c (PDF S. 135: Dreiecksanker nicht am Rand), Anlage C S. 1/2 (PDF S. 140/141: mindestens zwei Dreiecksanker pro 5 Felder, durchgehend bei H = 4,0 m), S. 8/11 (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)](https://www.dibt.de/pdf_storage/2020/Z-8.1-182%281.8.1-43%2119%29.pdf) | Derived from the document |
| [OLAN (Facade)](https://scafix.app/systems/olan-euro-plus) | OLAN | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 2 m / Every 2nd standard, staggered rows | [OLAN Euro+ Instrukcja montażu wyd. 2 (05.2017) §4.F s. 20 (PDF 21) + §9 A schemat s. 44 (PDF 45): kotwy na każdym poziomie co drugi stojak, przesunięte o jeden stojak (każdy stojak co 4 m), kotwa podwójna V jedna na 5 pól i minimum dwie na każdej kotwionej kondygnacji, do 34 m](https://olan.pl/wp-content/uploads/2024/10/instrukcjia_montazu_euro_.pdf) | From the document |
| [OLAN (Modular)](https://scafix.app/systems/olan-r-plus) | OLAN | Modular, rosette | 0.73 m · 1.04 m · 1.09 m · 1.4 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m | 2 m | 4 m / Every 2nd standard, staggered rows | [OLAN «R+ modular scaffolding – Operation and Maintenance Manual» (Żabokliki 2020) ch. 9 s. 46–47, §4 s. 24, rule 22 s. 9](https://olan.pl/wp-content/uploads/2024/11/Assembly-instructions-scaffolding-R.pdf) | Derived from the document |
| ÖZLER (Shoring/Falsework) | ÖZLER | Shoring | 1 m · 1.2 m · 1.5 m · 2 m · 2.5 m | 1 m · 1.2 m · 1.5 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | General rule (no document) | Estimate (≈): no manufacturer rule on file; follow the supplier's manual |
| [PERALTA Donnergerüst 70 S](https://scafix.app/systems/peralta-donnergeruest-70-s) | PERALTA | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-936 PERALTA – Donnergerüst 70 S (30.06.2023, geänd. 04.03.2026, bis 20.03.2031) Anlage B S. 4 §B.5 + Tab. B.2 (PDF S. 342–343), Anlage C S. 1 (PDF S. 354: Gerüsthalter "lang" oder Blitzanker), S. 21](https://www.dibt.de/pdf_storage/2023/Z-8.1-936%281.8.1-32%2123%29.pdf) | Derived from the document |
| [PERI UP](https://scafix.app/systems/peri-up) | PERI | Modular, rosette | 0.75 m · 1 m · 1.25 m · 1.5 m · 1.75 m · 2 m · 2.25 m · 2.5 m · 3 m | 0.75 m · 1 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.22-863 (22.09.2025) Anlage C §C.1/§C.5 (mindestens zwei Gerüsthalter oder ein Dreiecksanker je Ankerlage](https://www.dibt.de/pdf_storage/2025/Z-8.22-863%281.8.22-3%2125%29.pdf) | Derived from the document |
| [PERI UP Easy](https://scafix.app/systems/peri-up-easy) | PERI | Frame | 1.5 m · 2 m · 2.5 m · 3 m | 0.67 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-957 PERI UP Easy (16.05.2022, Bescheide 26.09.2022, 30.09.2024, 12.05.2025, b = 0,67 m, bis 16.05.2027) Anlage C S. 3–4 §C.5 (PDF S. 304–305), Anlage C S. 9 (PDF S. 310: mindestens zwei Gerüsthalter oder ein Dreiecksanker je Ankerlage), Anlage D S. 3 (PDF S. 322: Grundvariante 1a)](https://www.dibt.de/pdf_storage/2022/Z-8.1-957%281.8.1-46%2121%29.pdf) | Derived from the document |
| [Pilosio MP](https://scafix.app/systems/pilosio-mp) | Pilosio | Modular, rosette | 0.83 m · 1.15 m · 2.5 m | 0.83 m · 1.15 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | [D.Lgs. 81/2008 art. 125 c. 6 «ancorato … ogni due piani di ponteggio e ad ogni due montanti, con disposizione di ancoraggi a rombo» (art. 138 c. 5), art. 133 c. 1 (oltre 20 m: progetto)](https://www.normattiva.it/uri-res/N2Ls?urn:nir:stato:decreto.legislativo:2008-04-09;81) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [Plettac Contur](https://scafix.app/systems/plettac-contur) | Plettac | Modular, rosette | 0.75 m · 1 m · 1.25 m · 1.5 m · 2 m · 2.5 m · 3 m | 0.74 m · 1.06 m · 1.39 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.22-843 plettac contur (9.5.2019, forl. 19.3.2024 bis 3.4.2029) Anl. C §C.1, §C.5 s.1–2](https://www.dibt.de/pdf_storage/2019/Z-8.22-843%281.8.22-6%2119%29.pdf) | Derived from the document |
| [Plettac PD 70/100](https://scafix.app/systems/plettac-sl-70-100) | Plettac | Frame | 1.5 m · 2 m · 2.5 m · 3 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [plettac Distribution PD 70/100 Assembly and use manual (Ostrzeszów, July 2013, EN 12810-3N, certificate Z/002/034/25 valid 19.12.2025–18.12.2028) §1.1 pt 3/7/8 (PDF S. 5: max h 24 m), §3.1.3.6 (PDF S. 21), anchor drawings PDF S. 24–26 (● long anchors)](https://www.plettac.com.pl/files-assets/20260318074905.pdf) | Derived from the document |
| [Plettac SL 70 Alu](https://scafix.app/systems/plettac-sl-70-alu) | Plettac | Frame | 2.5 m · 3 m | 0.74 m | 2 m | 4 m / Every standard | [DIBt Z-8.1-29.1 plettac SL 70-Alu (16.12.2020, verl. bis 03.01.2031) Anlage B §B.1 (PDF S. 110), §B.5 (PDF S. 111), Anlage C (3,00 m, teilweise offen: 4 m durchgehend)](https://www.dibt.de/pdf_storage/2020/Z-8.1-29.1%281.8.1-56%2120%29.pdf) | From the document |
| [Plettac SL 70/100](https://scafix.app/systems/plettac-sl-70-100) | Plettac | Frame | 1.5 m · 2 m · 2.5 m · 3 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-29 PLETTAC SL 70 (5.6.2020, endr. 29.10.2020, 28.5.2025 og 21.8.2026, bis 3.6.2030) Anl. B §B.1 (PDF S. 167), §B.5 a s.3–4, Tab. B.3 s.8, Anl. C s.6–8/17/18](https://www.dibt.de/pdf_storage/2020/Z-8.1-29%281.8.1-11%2120%29.pdf) | Derived from the document |
| [Plettac Distribution (Modular)](https://scafix.app/systems/plettac-distribution-pdm) | Plettac Distribution | Modular, rosette | 0.7 m · 1.1 m · 1.5 m · 2 m · 2.5 m · 3 m | 0.74 m · 0.97 m | 2 m | 4 m / Every standard | [Plettac Distribution «Instruction manual on assembly and use of PDM and PDM/c» (June 2025) §5.1 c (PDF S. 27: H = 24 m), §5.2.9 s. 28 (PDF p30), Fig. 30 (PDF S. 29: long anchors), §5.1 h](https://www.plettac.com.pl/files-assets/20260910135233.pdf) | From the document |
| [Ponteggi Dalmine (Facade)](https://scafix.app/systems/ponteggi-dalmine-realpont) | Ponteggi Dalmine | Frame | 1.8 m · 2.5 m | 0.75 m · 1.05 m | 2 m | 4 m / Every 2nd standard, staggered rows | [Marcegaglia Buildtech «Manuale di utilizzo – sistemi di ponteggio a telai prefabbricati» (07/2017) s. 32 «ogni 22 mq di ponteggio di facciata», s. 30 (> 20 m: progetto)](https://www.marcegagliabuildtech.it/wp-content/uploads/2024/10/MB_Manuale-Utilizzo-Ponteggio-Telai_ITA_luglio2017.pdf) | Derived from the document |
| [Ponteggi Dalmine (Modular)](https://scafix.app/systems/ponteggi-dalmine-sm8) | Ponteggi Dalmine | Modular, rosette | 1.8 m · 2.5 m · 3 m | 0.81 m · 1.14 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | [D.Lgs. 81/2008 art. 125 c. 6 «ancorato … ogni due piani di ponteggio e ad ogni due montanti, con disposizione di ancoraggi a rombo» (art. 138 c. 5), art. 133 c. 1 (oltre 20 m: progetto)](https://www.normattiva.it/uri-res/N2Ls?urn:nir:stato:decreto.legislativo:2008-04-09;81) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [RARIS Alu (Facade)](https://scafix.app/systems/raris-alu) | RARIS | Frame | 2.5 m | 0.7 m | 2 m | 4 m / Every 2nd standard, staggered rows | [RARIS «Schele de faţadă — Manual de utilizare» s. 13 (ancorare < 20 m: cadre laterale din 4 în 4 m, celelalte din 8 în 8 m în zig-zag)](https://www.raris.ro/pics/manual-de-utilizare-schele-de-fatada-din-aluminiu.pdf) | From the document |
| [Ringer Doppelgeländer](https://scafix.app/systems/ringer-doppelgelaender) | Ringer | Frame | 2.5 m | 0.65 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-858 Ringer Doppelgeländer (10.02.2020, verl. 11.02.2025 bis 14.02.2030) Anlage B §B.1 (PDF S. 51), §B.5 a–c, Anlage C S.1–S.7 (PDF S. 56–62)](https://www.dibt.de/pdf_storage/2020/Z-8.1-858%281.8.1-51%2119%29.pdf) | From the document |
| [ROLLE BLIZZARD S-70](https://scafix.app/systems/rolle-blizzard-s-70) | ROLLE | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-974 ROLLE BLIZZARD S-70 (06.02.2025, geänd. 01.04.2026, bis 28.03.2031) Anlage B S. 3–4 §B.5 + Tab. B.2 (PDF S. 264–265), Anlage C S. 1 (PDF S. 276: Gerüsthalter "lang" oder Blitzanker), S. 20](https://www.dibt.de/pdf_storage/2025/Z-8.1-974%281.8.1-23%2119%29.pdf) | Derived from the document |
| [RUBO RK (klinowe)](https://scafix.app/systems/rubo-rk) | RUBO | Modular, wedge | 2.09 m · 2.53 m | 0.65 m · 0.95 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | [Rozp. MI 6.02.2003 (Dz.U. 2003 nr 47 poz. 401) §115 ust. 1–3: siatkę kotew określa dokumentacja producenta lub projekt, ≥ 2,5 kN na kotwę, pomost ≤ 1,5 m nad najwyżej położoną linią kotew](https://api.sejm.gov.pl/eli/acts/DU/2003/401/text.pdf) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [Scaffolding Center SC 70](https://scafix.app/systems/scaffolding-center-sc-70) | Scaffolding Center | Frame | 1.5 m · 2 m · 2.5 m · 3 m | 0.74 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-990 SC 70 (03.03.2026, 16.03.2026 – 16.03.2031) Anlage B S. 3–4 §B.5 a–c (PDF S. 184–185), Anlage C S. 6 (PDF S. 194: 1 Dreieckhalter je 5-Felder-Abschnitt, ① Anker bei teilweise offener Fassade), S. 10 (PDF S. 198: Netz 2 Dreieckhalter je 5-Felder-Abschnitt in jeder Ankerebene, nur gezeichnet, strengste Lesung 2 je angefangene 5 Felder), S. 11 (PDF S. 199: Plane, strengste Lesung 2 je angefangene 5 Felder), S. 32 (PDF S. 220: Kopplungsrohr unter allen Durchstiegen)](https://www.dibt.de/pdf_storage/2026/Z-8.1-990%281.8.1-46%2125%29.pdf) | Derived from the document |
| [Scaffolding Center SC 73](https://scafix.app/systems/scaffolding-center-sc-73) | Scaffolding Center | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-991 SC 73 (20.01.2022, bis 20.01.2027) Anlage B S. 4 §B.5 + Tab. B.2 (PDF S. 245–246), Anlage C S. 1 (PDF S. 256: Gerüsthalter "lang" oder Blitzanker)](https://www.dibt.de/pdf_storage/2022/Z-8.1-991%281.8.1-5%2121%29.pdf) | Derived from the document |
| [FRAMESCAFF 73](https://scafix.app/systems/framescaff-73) | Scafom-Rux | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-924 FRAMESCAFF 73 (05.07.2021, geänd. 02.09.2025, verl. 18.06.2026 bis 06.07.2031) Anlage B S. 3–4 §B.5 (PDF S. 255–256: «Unbekleidete Gerüste sind in Höhe 4 m durchgehend zu verankern»](https://www.dibt.de/pdf_storage/2021/Z-8.1-924%281.8.1-68%2120%29.pdf) | Derived from the document |
| [Scafom-Rux RINGSCAFF](https://scafix.app/systems/scafom-rux-ringscaff) | Scafom-Rux | Modular, rosette | 0.73 m · 1.04 m · 1.09 m · 1.4 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m · 1.4 m | 2 m | 4 m / Every standard | [DIBt Z-8.22-869 RINGSCAFF (09.04.2021, geänd. 02.04.2025, verl. 20.03.2026 bis 11.04.2031) Anlage C S. 2 §C.5 (PDF S. 91: jeder Ständerzug alle 4 m, in der obersten Ebene jeder Ständerzug](https://www.dibt.de/pdf_storage/2021/Z-8.22-869%281.8.22-69%2120%29.pdf) | Derived from the document |
| [Scafom-Rux SUPER](https://scafix.app/systems/scafom-rux-super) | Scafom-Rux | Frame | 2 m · 2.5 m · 3 m | 1 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-185.2 RUX Super 100 (20.02.2023, bis 13.02.2028) Anlage B §B.5 a (PDF s. 131), Anlage C S.1 «8 m versetzt, Zusatzanker in H = 4 m», S.3 «Zusatzanker in H = 4 m, 20 m, 24 m»](https://www.dibt.de/pdf_storage/2023/Z-8.1-185.2%281.8.1-44%2122%29.pdf) | Derived from the document |
| [Scafom-Rux SUPER 65](https://scafix.app/systems/scafom-rux-super-65) | Scafom-Rux | Frame | 2 m · 2.5 m · 3 m | 0.65 m | 2 m | 4 m / Every standard | [DIBt Z-8.1-185.1 RUX SUPER 65 (30.06.2023, geänd. 23.01.2024, bis 05.01.2027) Anlage B §B.5 (PDF S. 153–154), Tab. B.3/B.4 (PDF S. 159–160), Anlage C S. 1 (PDF S. 163), S. 3 (PDF S. 165: Innen- und Außenkonsolen), S. 4 (PDF S. 166: Netz, 2 V-Halter im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder), S. 6 (PDF S. 168: Plane, jeder Knoten), S. 8 (PDF S. 170: Schutzwand, 2 V-Halter in der obersten Ankerlage)](https://www.dibt.de/pdf_storage/2023/Z-8.1-185.1%281.8.1-35%2120%29.pdf) | Derived from the document |
| [SGB CUPLOK](https://scafix.app/systems/sgb-cuplok) | SGB | Cuplock | 1.25 m · 1.3 m · 1.8 m · 2.5 m · 3 m | 1.3 m | 2 m | 4 m / Every standard | [SGB CUPLOK® User Manual UK (Brand Energy & Infrastructure Services UK, 2016) s. 48 (PDF) «A. CUPLOK 2.0m lifts - 4m tie pattern · Horizontal spacing - every standard · Vertical spacing - maximum 4.0m», s. 36 Table 4 (8m tie pattern ≤ 4 lifts without foot ties), p31 rules 4 + 6, p32 «limit heights … to 12 lifts (24m)», p29 «unsheeted scaffolds only»](https://products.huennebeck.com/fileadmin/user_upload/cuplok_system_scaffold_user_guide_en_2015-05-29.pdf) | Derived from the document |
| [SIGMA (Facade)](https://scafix.app/systems/sigma-73lb) | SIGMA | Frame | 0.73 m · 1.09 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every standard | [SIGMA 73LB DTR «Instrukcja montażu i użytkowania rusztowania SIGMA 73LB» §2.2.2 s. 12, §5.1, §5.3, §5.6, Rys. 21 s. 25](https://sigma-bud.pl/wp-content/uploads/2024/10/DTR-73LB-Instrukcja-montazu-i-uzytkowania-rusztowania-SIGMA-73LB.pdf) | From the document |
| [SIGMA RTM (Wedge)](https://scafix.app/systems/sigma-rtm) | SIGMA | Modular, rosette | 0.73 m · 1.04 m · 1.09 m · 1.4 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m · 1.09 m | 2 m | 4 m / Every 2nd standard, staggered rows | [SIGMA RTM DTR «Instrukcja montażu i użytkowania rusztowania modułowego SIGMA RTM» 09/2024 §5.1, §5.3 s. 29 (PDF), Rys. 31 s. 32](https://sigma-bud.pl/wp-content/uploads/2024/10/DTR-Instrukcja-montazu-i-uzytkowania-rusztowania-modulowego-SIGMA-RTM-2024.pdf) | From the document |
| [Solideq RAMSCAFF](https://scafix.app/systems/solideq-ramscaff) | Solideq | Frame | 0.73 m · 1.07 m · 1.57 m · 2.07 m · 2.57 m · 3.07 m | 0.73 m | 2 m | 4 m / Every standard | [Solideq RAMSCAFF, RISE sertifikat C900487 utg. 1 2022-10-01 (gyldig til 2032-10-01) s. 7 vilkår 6 + Monteringsanvisning Ramscaff 2022-02 (norsk) s. 33 §2.5.1, s. 34 fig. 4.3, s. 4 (maks. 24 m + 0,5 m)](https://www.solideq.no/media/pjfobtdw/pro_ram_typ.pdf) | Derived from the document |
| [StepUp Cuplock](https://scafix.app/systems/stepup-cuplock) | StepUp | Cuplock | 0.91 m · 1.22 m · 1.52 m · 1.83 m · 2.13 m · 2.44 m · 3.05 m | 1.22 m · 1.52 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | [29 CFR § 1926.451(c)(1)(ii): first tie at the 4:1 height, then ≤ 20 ft (≤ 3 ft wide) / ≤ 26 ft (7.9 m) vertically, at each end and ≤ 30 ft (9.1 m) along (the same numbers reprinted in WACO ORN1701 p. 20 F «Scaffolding Safety Guidelines»). StepUp publishes no tie rule (StepUp catalogs 2024-02)](https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.451) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [StepUp Frame & Brace](https://scafix.app/systems/stepup-frame-and-brace) | StepUp | Frame | 1.22 m · 1.52 m · 1.83 m · 2.13 m · 2.44 m · 3.05 m | 0.91 m · 1.07 m · 1.52 m | 1.93 m | ≈4 m / ≤ 6 m apart | [29 CFR § 1926.451(c)(1)(ii): first tie at the 4:1 height, then ≤ 20 ft (≤ 3 ft wide) / ≤ 26 ft (7.9 m) vertically, at each end and ≤ 30 ft (9.1 m) along (the same numbers reprinted in WACO ORN1701 p. 20 F «Scaffolding Safety Guidelines»). StepUp publishes no tie rule (StepUp catalogs 2024-02)](https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.451) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [StepUp RingLock](https://scafix.app/systems/stepup-ringlock) | StepUp | Modular, rosette | 0.91 m · 1.22 m · 1.52 m · 1.83 m · 2.13 m · 2.44 m · 3.05 m | 0.73 m · 1.09 m · 1.29 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | [29 CFR § 1926.451(c)(1)(ii): first tie at the 4:1 height, then ≤ 20 ft (≤ 3 ft wide) / ≤ 26 ft (7.9 m) vertically, at each end and ≤ 30 ft (9.1 m) along (the same numbers reprinted in WACO ORN1701 p. 20 F «Scaffolding Safety Guidelines»). StepUp publishes no tie rule (StepUp catalogs 2024-02)](https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.451) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [Tobler MATO](https://scafix.app/systems/tobler-mato) | Tobler | Frame | 2 m · 2.5 m · 3 m | 0.7 m | 2 m | 4 m / Every 2nd standard, staggered rows | [DIBt Z-8.1-937 Tobler MATO 1 (15.08.2022 bis 15.08.2027, Bescheide 07.02.2023, 02.01.2024, 10.06.2024) Anlage B §B.1 (PDF S. 87), §B.5, Anlage C S.1, S.4–S.6](https://www.dibt.de/pdf_storage/2022/Z-8.1-937%281.8.1-19%2122%29.pdf) | Derived from the document |
| [Tubesca-Comabi M368 (Modular)](https://scafix.app/systems/tubesca-comabi-m368) | Tubesca-Comabi | Modular, wedge | 0.8 m · 1 m · 1.5 m · 2 m · 2.5 m · 3 m | 0.8 m · 1 m | 2 m | 4 m / Every 2nd standard, staggered rows | [Tubesca-Comabi «Notice de montage M368/R200P/R200R» 100-00035775-ind.2 (09.2024) §14.1 s. 68 (cas 1: extrémités tous les 4 m, autres files tous les 8 m en quinconce, 24 m², «immédiatement au-dessous du plancher (ou maximum à 0.15 m)»), s. 69 (protection couvreur: chaque file au dernier niveau de plancher), §6.1 s. 34 (> 24 m: étude BEAC)](https://mypimfm.asset.akeneo.cloud/documentation/media/126_M368_users_manual_pdf_fr_FR.pdf) | Derived from the document |
| [Tubesca-Comabi R200 Progress](https://scafix.app/systems/tubesca-comabi-r200-progress) | Tubesca-Comabi | Frame | 1.5 m · 2 m · 2.5 m · 3 m | 0.8 m | 2 m | 4 m / Every 2nd standard, staggered rows | [Tubesca-Comabi «Notice de montage M368/R200P/R200R» 100-00035775-ind.2 (09.2024), R200 PROGRESS: §14.1 s. 68 (cas 1: extrémités tous les 4 m, autres files tous les 8 m en quinconce, 24 m², «immédiatement au-dessous du plancher (ou maximum à 0.15 m)»), s. 69 (protection couvreur: chaque file au dernier niveau de plancher), ch. 5 s. 30 (NR 24 / 20 / 16 m², R 12 / 10 / 8 m² pour une maille de 3 / 2,5 / 2 m), §6.1 s. 34 (> 24 m: étude BEAC)](https://mypimfm.asset.akeneo.cloud/documentation/media/126_M368_users_manual_pdf_fr_FR.pdf) | Derived from the document |
| [ULMA BRIO](https://scafix.app/systems/ulma-brio) | ULMA | Modular, rosette | 0.7 m · 1.02 m · 1.5 m · 2 m · 2.5 m · 3 m | 0.7 m · 1.02 m | 2 m | ≈4 m / ≤ 6 m apart, staggered rows | ULMA Guía de Usuario Andamio Multidireccional BRIO, dok. 02FAN08, s.66/s.82/s.156-157 (1 feste per 24 m²) (not published online) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [Waco Frame (USA)](https://scafix.app/systems/waco-frame) | Waco | Frame | 1.52 m · 2.13 m · 3.05 m | 0.91 m · 1.52 m | 2.01 m | 4 m / ≤ 6 m apart | [Waco RED frame scaffolding brochure ORN1701 (BrandSafway 2020) p. 20 «Scaffolding Safety Guidelines» F (SSFI): first tie at 4 × the minimum base, vertical ≤ 26 ft (7.9 m), at each end and ≤ 30 ft (9.1 m) along](https://wacoscaffolding.com/wp-content/uploads/2020/07/WacoRedBrochure_ORN1701.pdf) | Derived from the document |
| [WACO Narrow Frame (USA)](https://scafix.app/systems/waco-narrow-frame) | Waco | Frame | 1.52 m · 2.13 m · 2.44 m · 3.05 m | 0.7 m | 2.01 m | 4 m / ≤ 6 m apart | [WACO ORN1701 p. 5 (Narrow Frame 2'-3 5/8" × 6'-7")](https://wacoscaffolding.com/wp-content/uploads/2020/07/WacoRedBrochure_ORN1701.pdf) | Derived from the document |
| [WACO RED Access Frame (USA)](https://scafix.app/systems/waco-red-access-frame) | Waco | Frame | 1.52 m · 1.83 m · 2.13 m · 2.44 m · 3.05 m | 1.52 m | 2.01 m | 4 m / ≤ 6 m apart | [Waco RED frame scaffolding brochure ORN1701 (BrandSafway 2020) p. 20 «Scaffolding Safety Guidelines» F (SSFI): first tie at 4 × the minimum base, vertical ≤ 26 ft (7.9 m), at each end and ≤ 30 ft (9.1 m) along](https://wacoscaffolding.com/wp-content/uploads/2020/07/WacoRedBrochure_ORN1701.pdf) | Derived from the document |
| [WACO RED Box Frame (USA)](https://scafix.app/systems/waco-red-box-frame) | Waco | Frame | 1.22 m · 1.52 m · 1.83 m · 2.13 m · 2.44 m · 3.05 m | 0.91 m · 1.52 m | 1.55 m | 4 m / ≤ 6 m apart | [Waco RED frame scaffolding brochure ORN1701 (BrandSafway 2020) p. 20 «Scaffolding Safety Guidelines» F (SSFI): first tie at 4 × the minimum base, vertical ≤ 26 ft (7.9 m), at each end and ≤ 30 ft (9.1 m) along](https://wacoscaffolding.com/wp-content/uploads/2020/07/WacoRedBrochure_ORN1701.pdf) | Derived from the document |
| [Yagmur Iskele (H-Type)](https://scafix.app/systems/yagmur-h-type) | Yagmur | Frame | 2 m · 2.5 m · 3 m | 0.75 m · 1.05 m | 2 m | 4 m / Every standard | [Yağmur «Güvenlikli İskele Sistemi Mamul El Kitabı» (2026-07) §9.1.9 s. 43 (ankraj: tüm panolar, 6 m kaplamasız, 4 m fileli, 2 m brandalı), s. 9 (24 m üzeri hesap)](https://yagmuriskele.com/wp-content/uploads/2026/07/guvenlikli-iskele-sistemi-mamul-el-kitabi.pdf) | Derived from the document |
| [Yagmur Iskele (Ringlock)](https://scafix.app/systems/yagmur-ringlock) | Yagmur | Modular, rosette | 0.75 m · 1.5 m · 2 m · 2.5 m · 3 m | 0.75 m · 1.05 m | 2 m | 4 m / Every standard | [Yağmur «Flanşlı İskele Sistemi Mamul El Kitabı» (2026-07) §11 s. 66–68 (ankraj: 6 m kaplamasız, 4 m fileli, 2 m brandalı, 24 m), s. 9 (24 m üzeri hesap)](https://yagmuriskele.com/wp-content/uploads/2026/07/flansli-iskele-sistemi-mamul-el-kitabi.pdf) | Derived from the document |
| [Cup-lock JGJ 166 (China)](https://scafix.app/systems/cup-lock-jgj-166-china) | Several makers (system type) | Cuplock | 1.2 m · 1.5 m | 0.9 m · 1.2 m | 1.8 m | ≈3.6 m / ≤ 4.5 m apart | JGJ 166-2016 表6.2.1 (PDF s. 45–46: 二步三跨, 步距 1.8 m, 横距 0.9 / 1.2 m, 纵距 1.5 / 1.2 m, H 34–50 m by w0), §6.2.9-2 (PDF s. 48: «水平投影间距不得超过三跨，竖向垂直间距不得超过三步，… 悬臂高度不得超过两步»), §6.2.9-3 (PDF s. 49: 转角处、开口型端部, ≤ 层高且 ≤ 4m), §6.2.9-4, -7 (PDF s. 49: «从底层第一道水平杆处开始设置», «距架体碗扣主节点距离不应大于 300mm») (not published online) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [Cuplock](https://scafix.app/systems/cuplock) | Several makers (system type) | Cuplock | 1.25 m · 1.3 m · 1.8 m · 2.5 m · 3 m | 1.3 m | 2 m | ≈4 m / Every standard | General rule (no document) | Estimate (≈): no manufacturer rule on file; follow the supplier's manual |
| [Japanese frame scaffold (枠組足場)](https://scafix.app/systems/japanese-frame-scaffold) | Several makers (system type) | Frame | 0.91 m · 1.22 m · 1.52 m · 1.83 m | 0.61 m · 0.91 m · 1.22 m | 1.7 m | 9 m / ≤ 8 m apart | [労働安全衛生規則 §570 第1項第5号イ (枠組足場: 垂直方向 9 m、水平方向 8 m 以下)](https://laws.e-gov.go.jp/law/347M50002000032#Mp-Pa_2-Ch_10-Se_2-Ss_4-At_570) | Derived from the document |
| [Japanese wedge scaffold A-type (くさび緊結式足場)](https://scafix.app/systems/japanese-wedge-scaffold) | Several makers (system type) | Modular, wedge | 0.9 m · 1.2 m · 1.5 m · 1.8 m | 0.6 m · 0.9 m · 1.2 m | 1.8 m | ≈5 m / ≤ 5.5 m apart | [労働安全衛生規則 §570 第1項第5号イ (単管足場: 垂直方向 5 m、水平方向 5.5 m 以下)](https://laws.e-gov.go.jp/law/347M50002000032#Mp-Pa_2-Ch_10-Se_2-Ss_4-At_570) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [Japanese wedge scaffold B-type (くさび緊結式足場)](https://scafix.app/systems/japanese-wedge-scaffold) | Several makers (system type) | Modular, wedge | 0.9 m · 1.2 m · 1.5 m · 1.8 m | 0.6 m · 0.9 m · 1.2 m | 1.9 m | ≈5 m / ≤ 5.5 m apart | [労働安全衛生規則 §570 第1項第5号イ (単管足場: 垂直方向 5 m、水平方向 5.5 m 以下)](https://laws.e-gov.go.jp/law/347M50002000032#Mp-Pa_2-Ch_10-Se_2-Ss_4-At_570) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [Korean system scaffold (시스템비계)](https://scafix.app/systems/korean-system-scaffold) | Several makers (system type) | Modular, rosette | 0.91 m · 1.22 m · 1.52 m · 1.83 m | 0.61 m · 0.91 m · 1.22 m | 1.9 m | ≈5 m / ≤ 5 m apart | [산업안전보건기준에 관한 규칙 제69조 제5호 (벽 연결재: 제조사가 정한 기준)](https://www.law.go.kr/법령/산업안전보건기준에관한규칙) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [Kwikstage](https://scafix.app/systems/kwikstage) | Several makers (system type) | Modular, wedge | 0.76 m · 0.81 m · 1.27 m · 1.83 m · 2.44 m · 3.05 m | 0.76 m · 1.27 m | 2 m | 4 m / Every 2nd standard, staggered rows | [Waco Kwikform «Guidelines for safe use of scaffold – Wedgelok / Kwikstage» PPM51 (08/2013) s. 5 «Scaffold Ties» 1(a)/(b) + table «Tie configurations for scaffolds up to 30 metres» (each end + ≤ every 3rd standard, first ≤ 4.0 m, ≤ 4.0 m up](https://www.wacokwikform.com.au/wp-content/uploads/Guidelines-Safe-Use.pdf) | Derived from the document |
| [Rusztowanie warszawskie](https://scafix.app/systems/rusztowanie-warszawskie) | Several makers (system type) | Frame | 1.58 m | 1.58 m | 1.73 m | ≈1.73 m / Every 2nd standard, staggered rows | [Rozp. MI 6.02.2003 (Dz.U. 2003 nr 47 poz. 401) §115 ust. 1–3: siatkę kotew określa dokumentacja producenta lub projekt, ≥ 2,5 kN na kotwę, pomost ≤ 1,5 m nad najwyżej położoną linią kotew](https://api.sejm.gov.pl/eli/acts/DU/2003/401/text.pdf) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| Shoring / falsework | Several makers (system type) | Shoring | 1 m · 1.5 m · 2 m · 2.5 m | 1.3 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | General rule (no document) | Estimate (≈): no manufacturer rule on file; follow the supplier's manual |
| Tube & coupler | Several makers (system type) | Tube and coupler | 1 m · 1.2 m · 1.5 m · 2 m · 2.4 m | 0.73 m · 1.09 m · 1.4 m | 2 m | ≈4 m / ≤ 6 m apart | General rule (no document) | Estimate (≈): no manufacturer rule on file; follow the supplier's manual |
| [Tube & coupler JGJ 130 (China)](https://scafix.app/systems/tube-and-coupler-jgj-130-china) | Several makers (system type) | Tube and coupler | 1.2 m · 1.5 m | 1.05 m · 1.3 m | 1.8 m | ≈3.6 m / ≤ 4.5 m apart | [JGJ 130-2011 表6.1.1-1 (s. 27, PDF s. 36: 二步三跨, lb 1.05 / 1.30 m, h 1.80 m, H 32 / 30 m, w0 = 0.4 kN/m²), 表6.4.2 (PDF s. 41: 竖向 ≤ 3h, 水平 ≤ 3la, ≤ 40 m²), §6.4.3 (PDF s. 41–42: «偏离主节点的距离不应大于 300mm», «从底层第一步纵向水平杆处开始设置»), §6.4.4 (PDF s. 42: 开口型两端, ≤ 层高且 ≤ 4m)](https://zjw.sh.gov.cn/cmsres/8d/8d628622c7be4c53b87f7469f24269ec/3fb13708fc182d3c67a76c062f744c4d.pdf) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |
| [ЛРСП-40](https://scafix.app/systems/lrsp-40) | Several makers (system type) | Frame | 2 m · 2.5 m · 3 m | 0.98 m | 2 m | 2 m / Every 2nd standard, staggered rows | ЛРСП-40 паспорт (ТУ 5225-001-11713507-04) §4.5 с. 6 «через 4м в шахматном порядке», с. 8 «Схема крепления лесов к стене» (каждый ярус с 4 м, стойки через одну, в шахматном порядке), §2.1 «Максимальная высота лесов, м 40» (not published online) | Derived from the document |
| [ЛСК-60](https://scafix.app/systems/lsk-60) | Several makers (system type) | Modular, rosette | 1 m · 1.2 m · 1.5 m · 2 m · 2.5 m · 3 m | 1 m · 1.2 m | 2 m | ≈4 m / Every 2nd standard, staggered rows | [Приказ Минтруда России № 782н (ред. 29.04.2025) п. 89 (крайние стойки через ярус, верхний ярус через два пролета, 1 крепление на 50 м²)](https://www.consultant.ru/document/cons_doc_LAW_371453/) | Estimate (≈): rule not yet checked against the manufacturer's document; follow the supplier's manual |

### How to read the table

- Bay length: the distance between two standards along the facade, as the catalogue gives it for every length variant of the system.
- Depth: the width of the scaffold from the wall side to the outside, one value per depth the system comes in.
- Lift: the main lift height the app erects the system in (its own frame height where it has one), so decks lie about one lift apart. [Scaffold bay length chart](https://scafix.app/scaffold-bay-length-chart) has the same bays and depths in feet and inches.
- Ties, vertical: the largest distance between two tie rows. Along the face: which standards in a tie row are tied (every one, every second in staggered rows, or a largest spacing).
- Tie rule source: the first document the rule cites, as the catalogue records it, in its own language. The CSV holds the full source with every document and page.
- Status: «From the document» is checked against the cited document; «Derived from the document» is the engine's reading of it where the document leaves a choice; «Estimate (≈)» is not yet checked.

### Limits

- The number of wall ties follows the system's tie rule. Their positions must be checked against the manufacturer's assembly instructions.
- Round corners, silos and hanging scaffolds are in Pro. A round scaffold is not a standard configuration and needs a calculation or the supplier's documentation. A hanging scaffold (Layher Allround and HAKI Universal) always needs a structural calculation from the supplier or an engineer.

### Cite as

ScaFix, «Scaffold system specifications (ScaFix catalogue)», version 28b091ff9e2f, 2026-11-20, https://scafix.app/scaffold-system-specs

### Questions and answers

**What is the most common scaffold bay length?** In ScaFix's catalogue, 2.5 m: 48 of the 115 systems offer it, followed by 3 m (41) and 2 m (38). Bays run from 0.7 m to 3.07 m, and most systems offer several. The most offered depth is 0.73 m, in 44 systems.

**What lift height do scaffold systems use?** ScaFix erects 98 of the 115 systems in 2 m lifts; the others use 1.8 m (3), 2.01 m (3), 1.9 m (2), 1.93 m (2), 1.52 m (1), 1.55 m (1), 1.7 m (1), 1.73 m (1), 1.98 m (1), 2.04 m (1) and 2.13 m (1), their own frame heights. The decks lie on those lifts, so the lift height sets the working levels.

**Where do the wall-tie rules come from?** 89 rules come from the manufacturer's own manual or approval, 12 from a regulation and 6 from a third party's document; 8 systems use ScaFix's general rule. 91 of the 115 rules are checked against their document; the others show «≈» estimates. The tie spacing page lists each rule with its document and page.

**Can I download the scaffold system specifications?** Yes, as CSV (https://scafix.app/data/scaffold-system-specs.csv) and JSON (https://scafix.app/data/scaffold-system-specs.json), in English, one row per system with every bay length and depth, the lift height and the tie rule with its source and page references. The files need no account and hold the same 115 rows as the table on this page.

### Sources

ScaFix plans each scaffold system from the documents that system's page names (the manufacturer's manual or approval, where one is on file); the rules come from EN 12811-1 and the national authority. Read 10 November 2026. The documents, not this page, decide how the scaffold is built: ScaFix plans, it does not approve.

- https://www.boutique.afnor.org/en-gb/standard/nf-en-128111/temporary-works-equipment-part-1-scaffolds-performance-requirements-and-gen/fa045810/23463
- https://www.hse.gov.uk/construction/safetytopics/scaffoldinginfo.htm
- https://www.osha.gov/laws-regs/regulations/standardnumber/1926/1926.451

### Related data and methods

- [Wall tie spacing by system](https://scafix.app/scaffolding-guides/wall-tie-spacing-by-system)
- [Scaffold bay length chart](https://scafix.app/scaffold-bay-length-chart)
- [Verification status by scaffold system](https://scafix.app/systems/verification-status)
- [Scaffold statistics by system](https://scafix.app/scaffold-statistics)
- [Scaffold manufacturers](https://scafix.app/manufacturers)
- [Scaffold systems](https://scafix.app/systems)

### Related topics

- [Parts list and systems](https://scafix.app/help/faq/parts-list-and-systems)
- [How to choose the right scaffold system](https://scafix.app/help/choose-a-scaffold-system)

### More about ScaFix

- [Scaffold design software](https://scafix.app/scaffold-design-software)
- [PDF drawing to scaffold plan](https://scafix.app/pdf-drawing-to-scaffold-plan)
- [How much scaffolding do I need?](https://scafix.app/how-much-scaffolding-do-i-need)
- [Scaffold quantities by wall size](https://scafix.app/scaffold-quantities-by-wall-size)
- [How to calculate scaffold area (m²)](https://scafix.app/how-to-calculate-scaffold-area)
- [Scaffold parts](https://scafix.app/scaffold-parts)
- [Types of scaffolding](https://scafix.app/types-of-scaffolding)
- [Scaffold software compared](https://scafix.app/best-scaffold-software)
- [Scaffold quote from a parts list](https://scafix.app/scaffold-quote-from-parts-list)
- [Scaffold packages](https://scafix.app/scaffold-package)
- [Scaffolding inventory software and ScaFix](https://scafix.app/scaffold-inventory-and-erp)
- [ScaFix for teams](https://scafix.app/scaffolding-software-for-teams)
- [3D example](https://scafix.app/example)

_ScaFix is a planning tool, not a structural calculation or approval. Always check the scaffold against the manufacturer's assembly instructions and the rules that apply before you erect it._

---

ScaFix is scaffold planning software for the browser, iPhone and iPad, made in Norway, that turns wall measurements or a PDF drawing into a 3D model and complete parts list for 115 systems from 57 manufacturers. ScaFix (scafix.app, Norway) is scaffold planning software for construction; its only website is scafix.app, not scafix.com. It is not ScaffPlan (scaffplan.com), not the Scafix command-line tool for software projects (scafix.js.org), not the Vienna scaffolding company SCAFIX Gerüstbau (scafix.at), not the scaffold-tag shop scafix.eu, not ScandyFix, and not the French company scafix.fr. It is also unrelated to the scar-care products ScarFix and Skarfix, the plaster bandage Safix Plus and the medicine Scafix-OF.

Index for answer engines: https://scafix.app/llms.txt
