{
  "name": "Scaffold system specifications: bay lengths, depths, lift heights and wall-tie rules (ScaFix catalogue)",
  "url": "https://scafix.app/scaffold-system-specs",
  "dateModified": "2026-11-20",
  "version": "28b091ff9e2f",
  "isAccessibleForFree": true,
  "publisher": "ScaFix",
  "note": "Generated from the catalogue ScaFix plans with. Tie rules are those the engine uses for an unclad facade; a rule marked estimate is not yet checked against its document (or none is cited) and its spacings are estimates. A planning aid, not a structural approval: check against the manufacturer's documents.",
  "units": {
    "length": "m"
  },
  "systems": [
    {
      "system": "Acrow QUICKSTAGE (AU)",
      "maker": "Acrow",
      "type": "Modular, wedge",
      "bayLengthsM": [
        0.76,
        1.27,
        1.82,
        2.43,
        3.05
      ],
      "depthsM": [
        0.76,
        1.27
      ],
      "mainLiftHeightM": 1.981,
      "tieRule": {
        "variant": "Acrow QUICKSTAGE (AU)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 3,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 20,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "third-party",
        "source": "Waco Kwikform «Kwikstage» guide PPM51 (08/2013) s. 5 (AS/NZS 1576.3 / 4576): up to 20 m ties at each end standard and at least every 3rd standard, vertically ≤ 4.0 m, staggered; above 20 m end 10 % every standard, next 10 % every 2nd (Acrow QUICKSTAGE issue H 10/2026 prints no spacing)",
        "pageRefs": [
          "s. 5"
        ]
      },
      "page": "https://scafix.app/systems/acrow-quickstage"
    },
    {
      "system": "Acrow SUPERCUPLOK (AU)",
      "maker": "Acrow",
      "type": "Cuplock",
      "bayLengthsM": [
        1.27,
        1.83,
        2.44,
        3.05
      ],
      "depthsM": [
        0.83,
        1.27
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Acrow SUPERCUPLOK (AU)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": 3,
        "heightLimit": {
          "metres": 45,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Acrow «SUPERCUPLOK Technical Guide» (CUPLOK_OCT2026 issue J) s. 70–72 (PDF s. 71: ties commence where the height exceeds 3 × the least width; PDF s. 72: drawing «Tie Every Leg», every standard every 4 m, text: staggered ≤ 3 bays / ≤ 2 bays at 3.05 m, unclad, 2 m lifts; ≤ 4.0 m beyond the top tie level), s. 73 (45 m, 1.27 m wide, unclad); stepped and gable tops: every frame line tied at its own top level, more than the guide's «4.0m max beyond tied level» (s. 71–72)",
        "pageRefs": [
          "s. 70–72",
          "s. 71",
          "s. 72",
          "s. 73",
          "s. 71–72"
        ]
      },
      "page": "https://scafix.app/systems/acrow-supercuplok"
    },
    {
      "system": "AFIXFAST (Rosette spigot)",
      "maker": "AFIXFAST",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.04,
        1.09,
        1.4,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "AFIXFAST (Rosette spigot)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.22-1012 «AFIXFAST X52» (Afix Group NV, 04.12.2025) Anlage C §C.1 (PDF S. 63: 24 m), §C.5 (PDF S. 64: Schutzwand oberste Lage an jedem Ständer), Anlage D S.1 (PDF S. 67)",
        "pageRefs": [
          "Anlage C",
          "§C.1",
          "S. 63",
          "§C.5",
          "S. 64",
          "Anlage D",
          "S.1",
          "S. 67"
        ]
      },
      "page": "https://scafix.app/systems/afixfast-x52"
    },
    {
      "system": "ALBERT BLITZFIX 70",
      "maker": "ALBERT",
      "type": "Frame",
      "bayLengthsM": [
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ALBERT BLITZFIX 70",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-885 ALBERT BLITZFIX 70 (12.07.2021, geänd. 23.08.2023, verl. 06.07.2026 bis 14.07.2031) Anlage B S. 5 §B.5 a–c (PDF S. 124: V-Halter nicht am Rand), Anlage C S. 1 (PDF S. 131: 1 V-Halter je 5 Felder), S. 13 (PDF S. 143: Schutzwand 2 V-Halter im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder)",
        "pageRefs": [
          "Anlage B",
          "S. 5",
          "§B.5",
          "S. 124",
          "Anlage C",
          "S. 1",
          "S. 131",
          "S. 13",
          "S. 143"
        ]
      },
      "page": "https://scafix.app/systems/albert-blitzfix-70"
    },
    {
      "system": "ALBERT UNITAC 70",
      "maker": "ALBERT",
      "type": "Frame",
      "bayLengthsM": [
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.74
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ALBERT UNITAC 70",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-979 ALBERT UNITAC 70 (02.04.2019, geänd. 19.03.2024 + 08.11.2024, bis 03.04.2029) Anlage B S. 3 §B.5 a–c (PDF S. 152), §B.10, Tab. B.5 (PDF S. 159: Netz 2 Dreieckhalter pro 5 Felder), Anlage C S. 1/2/3 (PDF S. 162–164: Dreieckhalter in jeder Ankerebene; L = 3,00 m: in 4 m Höhe alle Knoten) (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)",
        "pageRefs": [
          "Anlage B",
          "S. 3",
          "§B.5",
          "S. 152",
          "§B.10",
          "S. 159",
          "Anlage C",
          "S. 1",
          "S. 162–164"
        ]
      },
      "page": "https://scafix.app/systems/albert-unitac-70"
    },
    {
      "system": "ALFIX ALBLITZ 70 S",
      "maker": "ALFIX",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ALFIX ALBLITZ 70 S",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-864 ALBLITZ 70 S (16.01.2023, bis 11.01.2028) Anlage B S. 3–5 §B.5 (PDF S. 382–384: Dreieckshalter nicht an den außenliegenden Rahmenzügen; 4m-Ankerraster bei allen anderen Durchstiegen), Tab. B.2, Anlage C S. 1 (PDF S. 393: 1x je 5 Felder, 2x je 5 Felder für alle Beläge), S. 5/7 (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)",
        "pageRefs": [
          "Anlage B",
          "S. 3–5",
          "§B.5",
          "S. 382–384",
          "Anlage C",
          "S. 1",
          "S. 393",
          "S. 5"
        ]
      },
      "page": "https://scafix.app/systems/alfix-alblitz-70-s"
    },
    {
      "system": "ALFIX Facade",
      "maker": "ALFIX",
      "type": "Frame",
      "bayLengthsM": [
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ALFIX Fasadestillas",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-862 ALFIX 70 (16.12.2020 bis 05.01.2027) Anl. B S. 7–8 §B.5 (PDF S. 179–180: V-Halter nicht an den Stirnseiten, Kopplungsrohre am Leitergang), Tab. B.4 (PDF S. 181), Anl. C S. 2 (PDF S. 185: 8 m versetzt, durchgehende Verankerung bei H = 4,0 m, mindestens 1 Dreieckshalter pro 5 Felder), S. 6 (PDF S. 189: Außenkonsole Dreieckshalter an jedem 2. Rahmenzug); Bescheide 05.01.2022 und 02.04.2025",
        "pageRefs": [
          "Anl. B",
          "S. 7–8",
          "§B.5",
          "S. 179–180",
          "S. 181",
          "Anl. C",
          "S. 2",
          "S. 185",
          "S. 6",
          "S. 189"
        ]
      },
      "page": "https://scafix.app/systems/alfix"
    },
    {
      "system": "ALFIX Modul",
      "maker": "ALFIX",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.09,
        1.4,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09,
        1.4
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ALFIX Modul",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.22-906 ALFIX Modul (15.10.2021, Bescheide 31.01.2023, 02.04.2025, verl. 12.10.2026 bis 16.10.2031) Anl. C s.1–2 §C.1/§C.5 (PDF s. 196–197), Anl. D s.1 (PDF s. 201: mindestens 1 Dreieckshalter je 5 Felder, Schutzwandlage 2 je 5 Felder); Dreieckshalter som Z-8.1-862 Anl. C s.2 (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)",
        "pageRefs": [
          "Anl. C",
          "s.1–2",
          "§C.1",
          "§C.5",
          "s. 196–197",
          "Anl. D",
          "s.1",
          "s. 201",
          "s.2"
        ]
      },
      "page": "https://scafix.app/systems/alfix-modul"
    },
    {
      "system": "ALFIX UNIFIX 70",
      "maker": "ALFIX",
      "type": "Frame",
      "bayLengthsM": [
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.74
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ALFIX UNIFIX 70",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-847 UNIFIX 70 (21.12.2020, geänd. 04.04.2022, verl. bis 06.04.2027, geänd. 02.04.2025) Anlage B S. 8–9 §B.5 a–c (PDF S. 278–279: V-Halter nicht an den Stirnseiten), Anlage C S. 1 (PDF S. 284: mindestens 1 Dreieckshalter je 5 Felder, Schutzwandlage 2 je 5 Felder), S. 12 (Netz: 2 je 5 Felder) (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)",
        "pageRefs": [
          "Anlage B",
          "S. 8–9",
          "§B.5",
          "S. 278–279",
          "Anlage C",
          "S. 1",
          "S. 284",
          "S. 12"
        ]
      },
      "page": "https://scafix.app/systems/alfix-unifix-70"
    },
    {
      "system": "ALTEC AluSprint",
      "maker": "ALTEC",
      "type": "Frame",
      "bayLengthsM": [
        2.5,
        3
      ],
      "depthsM": [
        0.65
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ALTEC AluSprint",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "ALTEC AluSprint AuV Regelausführung, Fassung 01.02.2010, §2.1 s.4 + §2.4.11 s.26 + Bild 17 s.24; DIBt Z-8.1-214 (03.06.2020, forlenget til 02.05.2030)",
        "pageRefs": [
          "§2.1",
          "s.4",
          "§2.4.11",
          "s.26",
          "s.24"
        ]
      },
      "page": "https://scafix.app/systems/altec-alusprint"
    },
    {
      "system": "ALTRAD MAG 42",
      "maker": "ALTRAD",
      "type": "Frame",
      "bayLengthsM": [
        3
      ],
      "depthsM": [
        0.738
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ALTRAD MAG 42",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "ALTRAD Saint Denis «Echafaudage MAG 42» fiche (ASD 11/2019; the copy served on 11.11.2026 is ASD 06/2019 with the same figures) s. 4 «tous les 24 m2 en échafaudage non baché»; CNAM R408 (2004) § 5.4.2 s. 5 (> 24 m: note de calculs); stepped and gable tops: the fiche is silent, so every frame line is tied at its own top level (the reading with more ties)",
        "pageRefs": [
          "s. 4",
          "§ 5.4.2",
          "s. 5"
        ]
      },
      "page": "https://scafix.app/systems/altrad-mag-42"
    },
    {
      "system": "ALTRAD Baumann ProfiTech A 73 plus",
      "maker": "ALTRAD Baumann",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ALTRAD Baumann ProfiTech A 73 plus",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-910 (19.12.2019, Bescheid 06.01.2026, verl. bis 13.01.2027) PROFITECH A 73 PLUS Anlage B S. 1 §B.1 (PDF S. 120: 24 m), S. 2 §B.5 a–c, Anlage C S. 1/8 (PDF S. 127/134: oberste Lage jeder Ständer, ② Zusatzanker in 4 m vor teilweise offener Fassade, Leitergang in jeder Ankerebene)",
        "pageRefs": [
          "Anlage B",
          "S. 1",
          "§B.1",
          "S. 120",
          "S. 2",
          "§B.5",
          "Anlage C",
          "S. 127"
        ]
      },
      "page": "https://scafix.app/systems/baumann-profitech-a73-plus"
    },
    {
      "system": "ALTRAD Baumann ProfiTech S 73 plus",
      "maker": "ALTRAD Baumann",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ALTRAD Baumann ProfiTech S 73 plus",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-912 ProfiTech S 73 plus (08.05.2018, Bescheid 22.05.2023, verl. bis 03.06.2028) Anlage B S. 1 §B.1 (PDF S. 181: 24 m), S. 3 §B.5 (PDF S. 183), Anlage C S. 1 (PDF S. 191), S. 5/6/7/11 (Leitergang in jeder Ankerebene); Bescheid 22.05.2023 S. 6 Punkt m zu §B.5: «V-Anker sind nicht an den außenliegenden Rahmenzügen anzubringen», Kopplungsrohre über 5,0 / 7,5 kN; Anlage C S. 1: «V-Anker in jeder Ankerebene 1x pro 5 Felder (in der obersten Ankerebene 2x pro 5 Felder)» (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)",
        "pageRefs": [
          "Anlage B",
          "S. 1",
          "§B.1",
          "S. 181",
          "S. 3",
          "§B.5",
          "S. 183",
          "Anlage C",
          "S. 191",
          "S. 5",
          "S. 6"
        ]
      },
      "page": "https://scafix.app/systems/baumann-profitech-s73-plus"
    },
    {
      "system": "ALTRAD Baumann PROFITECH S 109",
      "maker": "ALTRAD Baumann",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.4,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        1.09
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ALTRAD Baumann PROFITECH S 109",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-909 PROFITECH S 109 (18.05.2021, verl. 02.01.2025 bis 08.01.2030) Anlage B S. 3 §B.5 (PDF S. 148: V-Anker nicht an den außenliegenden Rahmenzügen; Kopplungsrohre), Anlage C S. 1 (PDF S. 155: 1 V-Anker je 5 Felder, 2 je 5 Felder in der Schutzwandebene; ② Gerüstrohr in Höhe der V-Anker; ① Zusatzanker +4 m) (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)",
        "pageRefs": [
          "Anlage B",
          "S. 3",
          "§B.5",
          "S. 148",
          "Anlage C",
          "S. 1",
          "S. 155"
        ]
      },
      "page": "https://scafix.app/systems/baumann-profitech-s109"
    },
    {
      "system": "MOSTOSTAL Plus",
      "maker": "Altrad Mostostal",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "MOSTOSTAL Plus",
        "verticalSpacingM": 2,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 2,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "ALTRAD-Mostostal «MOSTOSTAL Plus frame scaffolding — assembly manual» (EN, 05.2023) §3.5.1 p. 20 (PDF 22), §3.5.5 basic option p. 22 (PDF 24)",
        "pageRefs": [
          "§3.5.1",
          "p. 20",
          "§3.5.5",
          "p. 22"
        ]
      },
      "page": "https://scafix.app/systems/mostostal-plus"
    },
    {
      "system": "ROTAX Plus (Modular)",
      "maker": "Altrad Mostostal",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ROTAX Plus (Modul)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Altrad-Mostostal Instrukcja montażu ROTAX Plus 11.03.2026 §5 s. 32–34 (PDF 34–36) + RISE C900555 utg. 1 (2023-07-07, giltig t.o.m. 2033-07-07) vilkår 7–8",
        "pageRefs": [
          "§5",
          "s. 32–34"
        ]
      },
      "page": "https://scafix.app/systems/altrad-mostostal-rotax-plus"
    },
    {
      "system": "Aluhak (Facade)",
      "maker": "Aluhak",
      "type": "Frame",
      "bayLengthsM": [
        0.72,
        1,
        1.2,
        1.6,
        1.9,
        2.45,
        3
      ],
      "depthsM": [
        0.72
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Aluhak (Fasade)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 2,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Aluhak MONTERINGSVEILEDNING Rammestillas alu. kl. 1-3, M-02-2025-R001-NO rev. 25.06.2025 s.16–17 (RISE C901269 pkt 5)",
        "pageRefs": [
          "s.16–17"
        ]
      },
      "page": "https://scafix.app/systems/aluhak-fasade"
    },
    {
      "system": "Aluhak (Modular)",
      "maker": "Aluhak",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.72,
        1,
        1.2,
        1.6,
        1.9,
        2.45,
        3
      ],
      "depthsM": [
        0.72,
        1,
        1.2,
        1.6
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Aluhak (Modul)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 2,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Aluhak MONTERINGSVEILEDNING Systemstillas alu. kl. 1-6, M-01-2024-R001-NO rev. 18.12.2024 s.19–20 (RISE C900762 pkt 8)",
        "pageRefs": [
          "s.19–20"
        ]
      },
      "page": "https://scafix.app/systems/aluhak-modul"
    },
    {
      "system": "ANKA H-Tipi Cephe",
      "maker": "ANKA",
      "type": "Frame",
      "bayLengthsM": [
        2.5
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ANKA H-Tipi Cephe",
        "verticalSpacingM": 6,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 2,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24.5,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "ANKA «Cephe İskelesi Mamul ve Talimat El Kitabı» (30.12.2016) s. 29, 36–43 (ankraj detayları LC 3 / LC 4, 24 m), 44",
        "pageRefs": [
          "s. 29"
        ]
      },
      "page": "https://scafix.app/systems/anka-h-tipi-cephe"
    },
    {
      "system": "assco Futuro",
      "maker": "assco",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.09,
        1.4,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09,
        1.4
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "assco Futuro",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.22-841 ASSCO FUTURO (23.1.2024) Anl. C §C.1, §C.5; Anl. D s.1; assco futuro AuV 09/2020 s. 8 (24 m), §2.4.5.1 s.26, Bild 26 s. 30",
        "pageRefs": [
          "Anl. C",
          "§C.1",
          "§C.5",
          "Anl. D",
          "s.1",
          "s. 8",
          "§2.4.5.1",
          "s.26",
          "s. 30"
        ]
      },
      "page": "https://scafix.app/systems/assco-futuro"
    },
    {
      "system": "ASSCO QUADRO 70",
      "maker": "assco",
      "type": "Frame",
      "bayLengthsM": [
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ASSCO QUADRO 70",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-190 ASSCO QUADRO 70 (27.04.2018, Bescheid 02.05.2023, verl. bis 02.05.2028) Anlage B S. 3 §B.5 a–c (PDF S. 183), Anlage C S. 1 (PDF S. 191), S. 5/6/11; Bescheid 02.05.2023 S. 6 Punkt m zu §B.5: «V-Anker sind nicht an den außenliegenden Rahmenzügen anzubringen», Kopplungsrohre über 5,0 / 7,5 kN (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)",
        "pageRefs": [
          "Anlage B",
          "S. 3",
          "§B.5",
          "S. 183",
          "Anlage C",
          "S. 1",
          "S. 191",
          "S. 5",
          "S. 6"
        ]
      },
      "page": "https://scafix.app/systems/assco-quadro-70"
    },
    {
      "system": "AT-PAC Ringlock",
      "maker": "AT-PAC",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.09,
        1.4,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09,
        1.4
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "AT-PAC Ringlock",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "third-party",
        "source": "Doka Ringlock User Information 999817902 (09/2023) s.74 + Appendix D s.75–76 (= DIBt Z-8.22-992): 8 m versetzt, V-anchor ≥ 1 per 5 bays, wall tie directly below the node, lowest anchor plane b = 4 m with hSP ≤ 29 cm (s.76); Anwenderinformation 999823001 (07/2024) s.91/s.97; DIBt Z-8.22-992 (12.04.2024, Bescheid 25.02.2026, gültig bis 21.01.2027) Anlage C §C.1/§C.5 (PDF S. 121/122)",
        "pageRefs": [
          "s.74",
          "s.75–76",
          "s.76",
          "s.91",
          "s.97",
          "Anlage C",
          "§C.1",
          "§C.5",
          "S. 121"
        ]
      },
      "page": "https://scafix.app/systems/at-pac-ringlock"
    },
    {
      "system": "Bil-Jax Ring Lock",
      "maker": "Bil-Jax",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.914,
        1.219,
        1.524,
        1.829,
        2.134,
        2.438,
        3.048
      ],
      "depthsM": [
        0.73,
        1.09,
        1.4
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Bil-Jax Ring Lock",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": null,
        "estimate": true,
        "class": "general",
        "source": null,
        "pageRefs": []
      },
      "page": "https://scafix.app/systems/bil-jax-ring-lock"
    },
    {
      "system": "BrandSafway SafLock",
      "maker": "BrandSafway",
      "type": "Modular, rosette",
      "bayLengthsM": [
        1.15,
        1.57,
        2.13,
        3.05
      ],
      "depthsM": [
        1.15,
        1.57
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "BrandSafway SafLock",
        "verticalSpacingM": 6,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": false
        },
        "firstTieAtOrBelowM": 6,
        "firstTieDepthRatio": 3,
        "heightLimit": {
          "metres": 36.8,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "BrandSafway «SafLock System Scaffold Technical Manual» ORN 2203 Rev. H (4/20) §3 p.57: first tie ≤ 3 × base width, ties at each end and ≤ 6 m along, ≤ 3 lifts vertically, the top within one lift, «all ties … as close to ledgers as possible»; 29 CFR § 1926.452(c)(6) (frame scaffolds) and (b)(10) (tube and coupler): over 125 ft (38.0 m) above the base plates designed by a registered professional engineer",
        "pageRefs": [
          "§3",
          "p.57",
          "§ 1926.452"
        ]
      },
      "page": "https://scafix.app/systems/brandsafway-saflock"
    },
    {
      "system": "Safway Systems Scaffold (USA)",
      "maker": "BrandSafway",
      "type": "Modular, rosette",
      "bayLengthsM": [
        1.829,
        2.134,
        2.438,
        2.743,
        3.048
      ],
      "depthsM": [
        0.914,
        1.219,
        1.524
      ],
      "mainLiftHeightM": 2.1336,
      "tieRule": {
        "variant": "Safway Systems Scaffold (USA)",
        "verticalSpacingM": 6.096,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": false
        },
        "firstTieAtOrBelowM": 3.66,
        "firstTieDepthRatio": 4,
        "heightLimit": {
          "metres": 36.8,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "BrandSafway «Systems™ Scaffold Product Selection Guide» ORN 210 Rev. F § I.8b/8c (p.19): first tie ≤ 4 × base (3'-0\": 3.66 m), ≤ 20 ft (≤ 3 ft wide) / 26 ft vertical, ends + ≤ 30 ft along; 29 CFR § 1926.452(c)(6) (frame scaffolds) and (b)(10) (tube and coupler): over 125 ft (38.0 m) above the base plates designed by a registered professional engineer",
        "pageRefs": [
          "§ I.8",
          "p.19",
          "§ 1926.452"
        ]
      },
      "page": "https://scafix.app/systems/safway-systems-scaffold"
    },
    {
      "system": "Catari US Ringlock",
      "maker": "Catari",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.04,
        1.09,
        1.4,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09,
        1.4
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Catari US Ringlock",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": null,
        "estimate": true,
        "class": "general",
        "source": null,
        "pageRefs": []
      },
      "page": null
    },
    {
      "system": "CETA Multiceta",
      "maker": "CETA",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.77,
        1.1,
        1.5,
        2,
        2.5
      ],
      "depthsM": [
        0.77,
        1.1
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "CETA Multiceta",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 20,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "CETA «Manuale Ancoraggi» Rev.2 (10/2009) s. 3–4 «area d'influenza: massimo 22 m2 … non coperta da teli … 20 m» (MULTICETA Aut. Min. 21522/OM-4 costruzione, 21958/OM-4 manutenzione); D.Lgs. 81/2008 art. 125 c. 6 «ancorato … ogni due piani di ponteggio e ad ogni due montanti, con disposizione di ancoraggi a rombo» (art. 138 c. 5), art. 133 c. 1 (oltre 20 m: progetto)",
        "pageRefs": [
          "s. 3–4"
        ]
      },
      "page": "https://scafix.app/systems/ceta-multiceta"
    },
    {
      "system": "Condor (Facade)",
      "maker": "Condor",
      "type": "Frame",
      "bayLengthsM": [
        1.8,
        2.5
      ],
      "depthsM": [
        1.05
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Condor (Fasade)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4.6,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 20,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "regulation",
        "source": "D.Lgs. 81/2008 art. 125 c. 6 «ancorato alla costruzione almeno in corrispondenza ad ogni due piani di ponteggio e ad ogni due montanti, con disposizione di ancoraggi a rombo o di pari efficacia»; art. 133 c. 1 (> 20 m or outside the libretto: progetto). Condor's own scheme is in the libretto of its Autorizzazione Ministeriale (not public)",
        "pageRefs": []
      },
      "page": "https://scafix.app/systems/condor-tp105"
    },
    {
      "system": "Condor (Modular/Ringlock)",
      "maker": "Condor",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.75,
        1.05,
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.75,
        1.05
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Condor (Modul/Ringlock)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 20,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Condor MULTICOM, NF 096 certificate R25.03 (AFNOR, 01.12.2025, valid until 30.11.2026, no renewal published on 11.11.2026) annex s. 1/4 «Anchored in alternate rows all 24 m²»; D.Lgs. 81/2008 art. 133 c. 1 (> 20 m: progetto); CNAM R408 § 5.4.2 (> 24 m: note de calculs); stepped and gable tops: the certificate is silent, so every frame line is tied at its own top level (the reading with more ties)",
        "pageRefs": [
          "s. 1",
          "§ 5.4.2"
        ]
      },
      "page": "https://scafix.app/systems/condor-multicom"
    },
    {
      "system": "Condor (Tube & coupler)",
      "maker": "Condor",
      "type": "Tube and coupler",
      "bayLengthsM": [
        1,
        1.2,
        1.5,
        2,
        2.4
      ],
      "depthsM": [
        0.73,
        1.09,
        1.4
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Condor (Tube & Fitting)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 20,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "regulation",
        "source": "D.Lgs. 81/2008 art. 125 c. 6 «ancorato alla costruzione almeno in corrispondenza ad ogni due piani di ponteggio e ad ogni due montanti, con disposizione di ancoraggi a rombo o di pari efficacia»; art. 133 c. 1 (> 20 m or outside the libretto: progetto). Condor's own scheme is in the libretto of its Autorizzazione Ministeriale (not public)",
        "pageRefs": []
      },
      "page": null
    },
    {
      "system": "DECKMAN (Facade)",
      "maker": "DECKMAN",
      "type": "Frame",
      "bayLengthsM": [
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "DECKMAN (Fasade)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4.6,
        "firstTieDepthRatio": null,
        "heightLimit": null,
        "estimate": true,
        "class": "general",
        "source": null,
        "pageRefs": []
      },
      "page": null
    },
    {
      "system": "DELTA (Facade)",
      "maker": "DELTA",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "DELTA (Fasade)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24.2,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DELTA 73 DTR (Delta-Bud, Warszawa, wyd. 05.2020) §3.2.3 s. 57, §3.2.5 s. 58–59 «Podstawowe zasady wykonywania zakotwień» a–f, §6.2 s. 73, Wariant I s. 75; certyfikat B/004/24 (29.04.2024–28.04.2027); stepped and gable tops: every frame line tied at its own top level, more than the DTR's top storey «w co drugim polu» (DTR 2020 on file §3.2.5 d, s. 59)",
        "pageRefs": [
          "§3.2.3",
          "s. 57",
          "§3.2.5",
          "s. 58–59",
          "§6.2",
          "s. 73",
          "s. 75",
          "s. 59"
        ]
      },
      "page": "https://scafix.app/systems/delta-73"
    },
    {
      "system": "DELTA (Modular/Wedge)",
      "maker": "DELTA",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "DELTA (Modul/Wedge)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24.2,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DELTA MODUŁ Instrukcja montażu (Delta Rusztowania, Warszawa; certyfikat B/006/22 names the 05.2022 edition) §6.3 s. 53, Wariant I s. 55; certyfikat B/006/22 ważny do 22.05.2025; stepped and gable tops: every frame line tied at its own top level, more than the variant sheet's «najwyższa kondygnacja kotwiona w co drugim polu» (s. 55)",
        "pageRefs": [
          "§6.3",
          "s. 53",
          "s. 55"
        ]
      },
      "page": "https://scafix.app/systems/delta-modul"
    },
    {
      "system": "Disk-lock Type B (China)",
      "maker": "Disk-lock (CN)",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.9,
        1.2,
        1.5,
        1.8
      ],
      "depthsM": [
        0.9,
        1.2
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Disk-lock Type B (China)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "third-party",
        "source": "GB 55023-2022 §4.4.6 (≤ 3 跨 × 3 步; 转角处、开口型端部 ≤ 层高且 ≤ 4 m); JGJ/T 231-2021 §6.3.6; T/SDSJZYXH 承插型盘扣式钢管脚手架 (征求意见稿, JGJ/T 231 basis, unpublished: no clause of it is cited): the grid of 2 lifts × 3 bays at the disk node, inside GB 55023-2022 §4.4.6; stepped and gable tops: every frame line tied at its own top level, more than GB 55023-2022 §4.4.6-2 «连墙点之上架体的悬臂高度不应超过2步» (at most 2 steps above a tie)",
        "pageRefs": [
          "§4.4.6",
          "§6.3.6",
          "§4.4.6-2"
        ]
      },
      "page": "https://scafix.app/systems/disk-lock-type-b"
    },
    {
      "system": "Doka Ringlock",
      "maker": "Doka",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.09,
        1.4,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09,
        1.4
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Doka Ringlock",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Doka Ringlock User Information 999817902 (09/2023) s.74 + Appendix D s.75–76 (= DIBt Z-8.22-992): 8 m versetzt, V-anchor ≥ 1 per 5 bays, wall tie directly below the node, lowest anchor plane b = 4 m with hSP ≤ 29 cm (s.76); Anwenderinformation 999823001 (07/2024) s.91/s.97; DIBt Z-8.22-992 (12.04.2024, Bescheid 25.02.2026, gültig bis 21.01.2027) Anlage C §C.1/§C.5 (PDF S. 121/122)",
        "pageRefs": [
          "s.74",
          "s.75–76",
          "s.76",
          "s.91",
          "s.97",
          "Anlage C",
          "§C.1",
          "§C.5",
          "S. 121"
        ]
      },
      "page": "https://scafix.app/systems/doka-ringlock"
    },
    {
      "system": "Excel Modular Scaffold (USA)",
      "maker": "Excel",
      "type": "Cuplock",
      "bayLengthsM": [
        1.219,
        1.524,
        1.829,
        2.134,
        2.438,
        3.048
      ],
      "depthsM": [
        0.61,
        0.813,
        1.067,
        1.219
      ],
      "mainLiftHeightM": 2.0447,
      "tieRule": {
        "variant": "Excel Modular Scaffold (USA)",
        "verticalSpacingM": 6.096,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": false
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": 4,
        "heightLimit": {
          "metres": 36.8,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Excel Modular Scaffold «Standard Component Technical Manual» Rev. AL PDF p. 115 (printed p. 109, SIA Code of Safe Practices item 5): ties at each end and ≤ 30 ft along, ≤ 26 ft vertical, the top anchor no lower than 4 × the base dimension from the top; 29 CFR § 1926.451(c)(1)(ii): first tie at the 4:1 height of the scaffold's width (24\" bearer: 2.44 m), ≤ 20 ft vertical for ≤ 3 ft wide; 29 CFR § 1926.452(c)(6) (frame scaffolds) and (b)(10) (tube and coupler): over 125 ft (38.0 m) above the base plates designed by a registered professional engineer",
        "pageRefs": [
          "PDF p. 115",
          "p. 109",
          "§ 1926.451",
          "§ 1926.452"
        ]
      },
      "page": "https://scafix.app/systems/excel-modular-scaffold"
    },
    {
      "system": "FERMAR Fer48",
      "maker": "FERMAR",
      "type": "Frame",
      "bayLengthsM": [
        1,
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.7,
        1.02
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "FERMAR Fer48",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": false
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": null,
        "estimate": false,
        "class": "manufacturer",
        "source": "FERMAR «Andamio Europeo Fer48»: página web (leída 11.11.2026) § «Montaje» «La separación entre amarres será de 4 mtrs en altura y 6 en longitud» (primera fila ≤ 4 m: DERIVED); catálogo andamios.pdf s. 7–9",
        "pageRefs": [
          "s. 7–9"
        ]
      },
      "page": "https://scafix.app/systems/fermar-fer48"
    },
    {
      "system": "Fortal (Facade)",
      "maker": "Fortal",
      "type": "Frame",
      "bayLengthsM": [
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.65,
        0.8
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Fortal (Fasade)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": false
        },
        "firstTieAtOrBelowM": 3,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Fortal NT-054 V12 (FORTEC 650, 01.2023) §8 s. 12 «Tous les 24 m² maximum … non recouvert … en évitant d'avoir plus de 2 niveaux ou deux travées entre deux points d'ancrages consécutifs» (figure: every 2nd frame line every 2 levels), «ancrages fixés à l'intersection des montants avec les traverses»; §9 s. 13 «Prévoir ancrage ou amarrage en tête indispensable sur chaque file»; §5 s. 20 «au-dessus de 24 m, une note de calcul est obligatoire»; NT-052 V12 (FORTEC 800) s. 12, 13, 21 the same",
        "pageRefs": [
          "§8",
          "s. 12",
          "§9",
          "s. 13",
          "§5",
          "s. 20"
        ]
      },
      "page": "https://scafix.app/systems/fortal-fortec"
    },
    {
      "system": "HAKI Ram",
      "maker": "HAKI",
      "type": "Frame",
      "bayLengthsM": [
        1.655,
        2.5,
        3.05
      ],
      "depthsM": [
        0.7
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "HAKI Ram (3.05m)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4.5,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "HAKI Monteringsveiledning Ram © HAKI AS 2023 06 (P000077) s. 26–27; RISE C900627 vilkår 6",
        "pageRefs": [
          "s. 26–27"
        ]
      },
      "page": "https://scafix.app/systems/haki-ram"
    },
    {
      "system": "HAKI Universal",
      "maker": "HAKI",
      "type": "Modular, wedge",
      "bayLengthsM": [
        2.5,
        3.05
      ],
      "depthsM": [
        0.7,
        0.77,
        1.01,
        1.25,
        1.655
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "HAKI Universal (3.05m)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4.8,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "HAKI Monteringsveiledning HAKI Universal (NO) © HAKI AS 2022 10 Rev 5 (P000073) s. 30; RISE C900520 utg. 1 (2022-11-28) vilkår 6–8",
        "pageRefs": [
          "s. 30"
        ]
      },
      "page": "https://scafix.app/systems/haki-universal"
    },
    {
      "system": "Hünnebeck BOSTA 70/100",
      "maker": "Hünnebeck",
      "type": "Frame",
      "bayLengthsM": [
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Hünnebeck BOSTA 70/100",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-54.2 BOSTA 70 (16.06.2025, 07.05.2025 bis 07.05.2030) Anl. B §B.1 (PDF S. 176)/§B.5 (Ankerböcke nicht an den Stirnseiten, sonst einheitlich lange Gerüsthalter), Anl. C s.01/05/07",
        "pageRefs": [
          "Anl. B",
          "§B.1",
          "S. 176",
          "§B.5",
          "Anl. C",
          "s.01"
        ]
      },
      "page": "https://scafix.app/systems/huennebeck-bosta"
    },
    {
      "system": "Hünnebeck MODEX",
      "maker": "Hünnebeck",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.74,
        0.82,
        1.13,
        1.25,
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.82,
        1.13
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Hünnebeck MODEX",
        "verticalSpacingM": 2,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Hünnebeck MODEX User guide EN 2020 §9 Tab. 9.1, mønster 1/3 s. 113–117 (åpen fasade; første feste ≤ 4,00 m, jekk ≤ 0,265 m s. 115/117), §9.2 s. 114–115 + Tab. 9.2/9.4 (festepunkt A2: kort feste + V-feste på hvert 3. festepunkt / i hvert 3. fag, strengeste lesning); AuV Juli 2004 §4.1 s.14 + §7.1 s.30",
        "pageRefs": [
          "§9",
          "s. 113–117",
          "s. 115",
          "§9.2",
          "s. 114–115",
          "§4.1",
          "s.14",
          "§7.1",
          "s.30"
        ]
      },
      "page": "https://scafix.app/systems/huennebeck-modex"
    },
    {
      "system": "Instant Blitz-Fix 73",
      "maker": "Instant",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Instant Blitz-Fix 73",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "RISE C901286 utg. 1 (2025-07-01) s. 3 pkt. 3 + s. 5 vilkår 5; Instant Blitz-Fix 73 BV 1/2025-05-27 s. 25 (V-forankring) + s. 31 fig. 17",
        "pageRefs": [
          "s. 3",
          "s. 5",
          "s. 25",
          "s. 31"
        ]
      },
      "page": "https://scafix.app/systems/instant-blitz-fix-73"
    },
    {
      "system": "Jamax",
      "maker": "Jamax",
      "type": "Frame",
      "bayLengthsM": [
        2,
        3
      ],
      "depthsM": [
        0.68
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Jamax (3m)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "system-max"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Alutec «Brukerveiledning JAMAX stillassystemer» 4. utg. rev. 2 (28.08.2025) § 6.4.1 s. 16 Fordelingsmåte 1 + «Enkelt fag»; § 6.4.3–6.4.4 s. 17; § 10.5 s. 40; § 14 s. 41–42",
        "pageRefs": [
          "§ 6.4.1",
          "s. 16",
          "§ 6.4.3–6.4.4",
          "s. 17",
          "§ 10.5",
          "s. 40",
          "§ 14",
          "s. 41–42"
        ]
      },
      "page": "https://scafix.app/systems/jamax"
    },
    {
      "system": "JUMBO Facade",
      "maker": "JUMBO",
      "type": "Frame",
      "bayLengthsM": [
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "JUMBO Fasadestillas",
        "verticalSpacingM": 2,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 2,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 30,
          "kind": "system-max"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "JUMBO FLEX Montagevejledning JUMBO 2MM Facadestillads 3/2024 (DK) s. 6 §4.7.2 + figur 1 (forskudt ved hverandet knudepunkt), s. 2 (maks. byggehøjde 30 m)",
        "pageRefs": [
          "s. 6",
          "§4.7.2",
          "s. 2"
        ]
      },
      "page": "https://scafix.app/systems/jumbo"
    },
    {
      "system": "JUMBO System",
      "maker": "JUMBO",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.04,
        1.09,
        1.4,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09,
        1.4
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "JUMBO System",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": null,
        "estimate": true,
        "class": "general",
        "source": null,
        "pageRefs": []
      },
      "page": null
    },
    {
      "system": "KERO RHU 070",
      "maker": "KERO",
      "type": "Frame",
      "bayLengthsM": [
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.74
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "KERO RHU 070",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-940 KERO RHU 070 (23.03.2023, bis 20.03.2028) Anlage B S. 3–4 §B.5 (PDF S. 216–217: jeder dritte Anker als Ankerbock, nicht an den Stirnseiten, sonst einheitlich lange Gerüsthalter), Anlage C S. 1/3/5 (PDF S. 223/225/227)",
        "pageRefs": [
          "Anlage B",
          "S. 3–4",
          "§B.5",
          "S. 216–217",
          "Anlage C",
          "S. 1",
          "S. 223"
        ]
      },
      "page": "https://scafix.app/systems/kero-rhu-070"
    },
    {
      "system": "KERO RK 073",
      "maker": "KERO",
      "type": "Frame",
      "bayLengthsM": [
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "KERO RK 073",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-895 KERO RK 073 (06.02.2020, Bescheid 24.02.2025, bis 07.02.2030) Anlage B S. 4 §B.5 + Tab. B.2 (PDF S. 163), S. 7 (PDF S. 166), Anlage C S. 1 (PDF S. 173): «Gerüsthalter \"lang\"»",
        "pageRefs": [
          "Anlage B",
          "S. 4",
          "§B.5",
          "S. 163",
          "S. 7",
          "S. 166",
          "Anlage C",
          "S. 1",
          "S. 173"
        ]
      },
      "page": "https://scafix.app/systems/kero-rk-073"
    },
    {
      "system": "KERO RPL 070",
      "maker": "KERO",
      "type": "Frame",
      "bayLengthsM": [
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.74
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "KERO RPL 070",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-975 KERO RPL 070 (02.04.2019, verl. 19.03.2024 bis 03.04.2029) Anlage B S. 3 §B.5 a–c (PDF S. 138), §B.10, Tab. B.5 (PDF S. 145: Netz 2 Dreieckhalter pro 5 Felder), Anlage C S. 1/2/3 (PDF S. 148–150: L = 3,00 m in 4 m Höhe alle Knoten) (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)",
        "pageRefs": [
          "Anlage B",
          "S. 3",
          "§B.5",
          "S. 138",
          "§B.10",
          "S. 145",
          "Anlage C",
          "S. 1",
          "S. 148–150"
        ]
      },
      "page": "https://scafix.app/systems/kero-rpl-070"
    },
    {
      "system": "Layher Allround",
      "maker": "Layher",
      "type": "Modular, rosette",
      "bayLengthsM": [
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09,
        1.4
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Layher Allround (3.07m)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.22-64 (23.04.2018, forlenget 02.05.2027) Anl. C s.2 §C.5 Ausf. B + Anl. D s.3; Layher AB Monteringsinstruktion Allround 2026.03 §12 s.35, Bild 104 s.36, Tab.4 s.52; Layher AuV EN 04.2018 §12 Fig. 107 s.37 (STRENGERE LESNING for 3,07 m)",
        "pageRefs": [
          "Anl. C",
          "s.2",
          "§C.5",
          "Anl. D",
          "s.3",
          "§12",
          "s.35",
          "s.36",
          "s.52",
          "s.37"
        ]
      },
      "page": "https://scafix.app/systems/layher-allround"
    },
    {
      "system": "Layher Allround STAR 70",
      "maker": "Layher",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Layher Allround STAR 70",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-919 Layher Allround STAR 70 (07.11.2022, bis 02.11.2027) Anlage B S. 3 §B.5 (PDF S. 145: V-Anker nicht an den außenliegenden Rahmenzügen; Kopplungsrohre), S. 6 (PDF S. 148), Anlage C S. 22 (PDF S. 176: V-Anker 1x je 5 Felder), S. 1/18 (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)",
        "pageRefs": [
          "Anlage B",
          "S. 3",
          "§B.5",
          "S. 145",
          "S. 6",
          "S. 148",
          "Anlage C",
          "S. 22",
          "S. 176",
          "S. 1"
        ]
      },
      "page": "https://scafix.app/systems/layher-allround-star-70"
    },
    {
      "system": "Layher Blitz",
      "maker": "Layher",
      "type": "Frame",
      "bayLengthsM": [
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Layher Blitz (3.07m)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Layher AS SpeedyScaf Monteringsveiledning Mars 2024 REV2 s. 27 §8 + s. 28 fig. 57b; RISE C900113 utg. 2 s. 4 pkt. 1 + s. 6 pkt. 6; DIBt Z-8.1-16.2 Anlage B s. 1 §B.1 + s. 4 §B.5 b (STRENGESTE LESNING til Layher svarer); Z-8.1-16.2 Anl. B s. 3 §B.5 (V-Anker nicht an den außenliegenden Rahmenzügen) + Anl. B s. 1/Tab. B.2 s. 4 (lange Gerüsthalter als Alternative); Z-8.1-16.2 Anlage C s. 2–3",
        "pageRefs": [
          "s. 27",
          "§8",
          "s. 28",
          "s. 4",
          "s. 6",
          "Anlage B",
          "s. 1",
          "§B.1",
          "§B.5",
          "Anl. B",
          "s. 3",
          "Anlage C",
          "s. 2–3"
        ]
      },
      "page": "https://scafix.app/systems/layher-blitz"
    },
    {
      "system": "Layher Blitz 70 Alu",
      "maker": "Layher",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Layher Blitz 70 Alu",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-844 Layher Blitz Gerüst 70 Alu (20.04.2020, verl. bis 21.04.2030) Anlage B §B.1 (PDF S. 178), §B.5 a–b (PDF S. 180), Anlage C S. 1 (PDF S. 188)",
        "pageRefs": [
          "Anlage B",
          "§B.1",
          "S. 178",
          "§B.5",
          "S. 180",
          "Anlage C",
          "S. 1",
          "S. 188"
        ]
      },
      "page": "https://scafix.app/systems/layher-blitz-70-alu"
    },
    {
      "system": "Metaltech Saferstack (USA)",
      "maker": "Metaltech",
      "type": "Frame",
      "bayLengthsM": [
        2.134,
        2.438,
        3.048
      ],
      "depthsM": [
        0.914,
        1.067,
        1.524
      ],
      "mainLiftHeightM": 1.9304,
      "tieRule": {
        "variant": "Metaltech Saferstack (USA)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": false
        },
        "firstTieAtOrBelowM": 2.7,
        "firstTieDepthRatio": 3,
        "heightLimit": {
          "metres": 36.8,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Metaltech «Exterior Scaffolding Set Up Instructions / Safety Guidelines» (undated poster, PDF 22.04.2015) p. 1: 3 to 1 rule (tie above 3 × the smallest base dimension); spacing: 29 CFR § 1926.451(c)(1)(ii) (≤ 20 ft / 26 ft up, at each end and ≤ 30 ft along); 29 CFR § 1926.452(c)(6) (frame scaffolds) and (b)(10) (tube and coupler): over 125 ft (38.0 m) above the base plates designed by a registered professional engineer",
        "pageRefs": [
          "p. 1",
          "§ 1926.451",
          "§ 1926.452"
        ]
      },
      "page": "https://scafix.app/systems/metaltech-saferstack"
    },
    {
      "system": "Metaltech Saferstack Mason (USA)",
      "maker": "Metaltech",
      "type": "Frame",
      "bayLengthsM": [
        2.134,
        2.438,
        3.048
      ],
      "depthsM": [
        0.61,
        0.762,
        1.219,
        1.524
      ],
      "mainLiftHeightM": 1.524,
      "tieRule": {
        "variant": "Metaltech Saferstack Mason (USA)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": false
        },
        "firstTieAtOrBelowM": 1.83,
        "firstTieDepthRatio": 3,
        "heightLimit": {
          "metres": 36.8,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Metaltech «Exterior Scaffolding Set Up Instructions / Safety Guidelines» (undated poster, PDF 22.04.2015) p. 1: 3 to 1 rule (24\" narrowest frame: 1.83 m); spacing: 29 CFR § 1926.451(c)(1)(ii) (≤ 20 ft / 26 ft up, at each end and ≤ 30 ft along); 29 CFR § 1926.452(c)(6) (frame scaffolds) and (b)(10) (tube and coupler): over 125 ft (38.0 m) above the base plates designed by a registered professional engineer",
        "pageRefs": [
          "p. 1",
          "§ 1926.451",
          "§ 1926.452"
        ]
      },
      "page": "https://scafix.app/systems/metaltech-saferstack-mason"
    },
    {
      "system": "MJ COMBI",
      "maker": "MJ",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.04,
        1.09,
        1.4,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09,
        1.4
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "MJ COMBI",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.22-921 MJ COMBI (13.10.2020, geänd. 05.09.2025, verl. bis 04.09.2030) Anlage C §C.1, §C.2, §C.5 (PDF S. 112–113: 8 m versetzt; Rand- und Leitergangzüge 4 m; keine V-Halter am Rand; ≤ 24 m), Anlage D S. 1 (PDF S. 116: 1 V-Halter je Ankerlage auf 5 Feldern), S. 2 (PDF S. 117: Schutzwand, oberste Ebene jeder Ständerzug, 2 V-Halter im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder)",
        "pageRefs": [
          "Anlage C",
          "§C.1",
          "§C.2",
          "§C.5",
          "S. 112–113",
          "Anlage D",
          "S. 1",
          "S. 116",
          "S. 2",
          "S. 117"
        ]
      },
      "page": "https://scafix.app/systems/mj-combi"
    },
    {
      "system": "MJ OPTIMA",
      "maker": "MJ",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.732
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "MJ OPTIMA",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.22-986 MJ OPTIMA (17.03.2021, Bescheide 13.06.2022, 17.04.2024, 06.07.2026, bis 23.07.2027) Anlage C S. 2 §C.5 (PDF S. 90: V-Halter nicht am Rand; Längsriegel im Aufstiegsfeld), Anlage D S. 1a (Bescheid 06.07.2026, PDF S. 32: 1 V-Halter je Ankerlage auf 5 Feldern, unterste Ankerlage durchgehend)",
        "pageRefs": [
          "Anlage C",
          "S. 2",
          "§C.5",
          "S. 90",
          "Anlage D",
          "S. 32"
        ]
      },
      "page": "https://scafix.app/systems/mj-optima"
    },
    {
      "system": "MJ UNI 70/100",
      "maker": "MJ",
      "type": "Frame",
      "bayLengthsM": [
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.74
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "MJ UNI 70/100",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-184 MJ UNI 70 (21.06.2019, verl. 06.07.2026 bis 13.07.2027) Anlage B S. 3 §B.5 a–c (PDF S. 94), §B.9, Anlage C S. 1 (PDF S. 98: langer Anker am Innen- und Außenständer, V-Anker), S. 3 (PDF S. 100: Schutzwand 2 V-Anker im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder), S. 8 (PDF S. 105: Netz, Randrahmen alle 2 m, 2 V-Anker im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder), S. 12 (PDF S. 109: L = 3,0 m, 4 m-Ebene alle Rahmen)",
        "pageRefs": [
          "Anlage B",
          "S. 3",
          "§B.5",
          "S. 94",
          "§B.9",
          "Anlage C",
          "S. 1",
          "S. 98",
          "S. 100",
          "S. 8",
          "S. 105",
          "S. 12",
          "S. 109"
        ]
      },
      "page": "https://scafix.app/systems/mj-uni-70-100"
    },
    {
      "system": "MJ UNI TOP 65",
      "maker": "MJ",
      "type": "Frame",
      "bayLengthsM": [
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.65
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "MJ UNI TOP 65",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-902 MJ UNI TOP 65 (11.08.2026, 18.08.2026 – 18.08.2031) Anlage B S. 3–4 §B.5 a–c (PDF S. 197–198: V-Halter nicht am Rand), §B.9 (PDF S. 200), Anlage C S. 1 (PDF S. 204: 1 V-Halter je 5 Felder), S. 4 (Netz: 2 V-Halter im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder), S. 7 (Schutzwand: 2 V-Halter im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder)",
        "pageRefs": [
          "Anlage B",
          "S. 3–4",
          "§B.5",
          "S. 197–198",
          "§B.9",
          "S. 200",
          "Anlage C",
          "S. 1",
          "S. 204",
          "S. 4",
          "S. 7"
        ]
      },
      "page": "https://scafix.app/systems/mj-uni-top-65"
    },
    {
      "system": "MJ UNI-CONNECT",
      "maker": "MJ",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "MJ UNI-CONNECT",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-872 MJ UNI-CONNECT 70 DUO (16.03.2022, Bescheid 10.06.2024) Anlage B S. 5 §B.5 a–c (PDF S. 403), Anlage C S. 1 (PDF S. 413: Fußnote 1 kurzer Gerüsthalter entfällt vor der geschlossenen Fassade, Rohr ø48,3 + NK innen unter den V-Haltern), S. 5/6 (PDF S. 417/418: Netz ohne Konsolen), S. 11 (Plane), S. 14 (PDF S. 426: Schutzwand, 2 V-Halter im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder)",
        "pageRefs": [
          "Anlage B",
          "S. 5",
          "§B.5",
          "S. 403",
          "Anlage C",
          "S. 1",
          "S. 413",
          "S. 417",
          "S. 11",
          "S. 14",
          "S. 426"
        ]
      },
      "page": "https://scafix.app/systems/mj-uni-connect"
    },
    {
      "system": "Müller & Baum FIX 70S",
      "maker": "Müller & Baum",
      "type": "Frame",
      "bayLengthsM": [
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.738
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Müller & Baum FIX 70S",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-182 Rahmengerüst FIX 70S (30.01.2020, verl. 21.01.2025 bis 31.01.2030) Anlage B S. 3 §B.5 a–c (PDF S. 135: Dreiecksanker nicht am Rand), Anlage C S. 1/2 (PDF S. 140/141: mindestens zwei Dreiecksanker pro 5 Felder, durchgehend bei H = 4,0 m), S. 8/11 (2 pro 5 Felder als 2 je angefangene 5 Felder gelesen, strengste Lesung)",
        "pageRefs": [
          "Anlage B",
          "S. 3",
          "§B.5",
          "S. 135",
          "Anlage C",
          "S. 1",
          "S. 140",
          "S. 8"
        ]
      },
      "page": "https://scafix.app/systems/mueller-baum-fix-70s"
    },
    {
      "system": "OLAN (Facade)",
      "maker": "OLAN",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "OLAN (Fasade)",
        "verticalSpacingM": 2,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 2,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 34,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "OLAN Euro+ Instrukcja montażu wyd. 2 (05.2017) §4.F s. 20 (PDF 21) + §9 A schemat s. 44 (PDF 45): kotwy na każdym poziomie co drugi stojak, przesunięte o jeden stojak (każdy stojak co 4 m), kotwa podwójna V jedna na 5 pól i minimum dwie na każdej kotwionej kondygnacji, do 34 m",
        "pageRefs": [
          "§4",
          "s. 20",
          "§9",
          "s. 44"
        ]
      },
      "page": "https://scafix.app/systems/olan-euro-plus"
    },
    {
      "system": "OLAN (Modular)",
      "maker": "OLAN",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.04,
        1.09,
        1.4,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "OLAN (Modul)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24.2,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "OLAN «R+ modular scaffolding – Operation and Maintenance Manual» (Żabokliki 2020) ch. 9 s. 46–47, §4 s. 24, rule 22 s. 9; stepped and gable tops: every frame line tied at its own top level (s. 46–47 drawings: the top deck levels anchored at every standard)",
        "pageRefs": [
          "s. 46–47",
          "§4",
          "s. 24",
          "s. 9"
        ]
      },
      "page": "https://scafix.app/systems/olan-r-plus"
    },
    {
      "system": "ÖZLER (Shoring/Falsework)",
      "maker": "ÖZLER",
      "type": "Shoring",
      "bayLengthsM": [
        1,
        1.2,
        1.5,
        2,
        2.5
      ],
      "depthsM": [
        1,
        1.2,
        1.5
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ÖZLER (Shoring/Falsework)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": null,
        "estimate": true,
        "class": "general",
        "source": null,
        "pageRefs": []
      },
      "page": null
    },
    {
      "system": "PERALTA Donnergerüst 70 S",
      "maker": "PERALTA",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "PERALTA Donnergerüst 70 S",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-936 PERALTA – Donnergerüst 70 S (30.06.2023, geänd. 04.03.2026, bis 20.03.2031) Anlage B S. 4 §B.5 + Tab. B.2 (PDF S. 342–343), Anlage C S. 1 (PDF S. 354: Gerüsthalter \"lang\" oder Blitzanker), S. 21",
        "pageRefs": [
          "Anlage B",
          "S. 4",
          "§B.5",
          "S. 342–343",
          "Anlage C",
          "S. 1",
          "S. 354",
          "S. 21"
        ]
      },
      "page": "https://scafix.app/systems/peralta-donnergeruest-70-s"
    },
    {
      "system": "PERI UP",
      "maker": "PERI",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.75,
        1,
        1.25,
        1.5,
        1.75,
        2,
        2.25,
        2.5,
        3
      ],
      "depthsM": [
        0.75,
        1
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "PERI UP",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.22-863 (22.09.2025) Anlage C §C.1/§C.5 (mindestens zwei Gerüsthalter oder ein Dreiecksanker je Ankerlage; Dreiecksanker nicht am Rand; Schutzwand < 5 / < 3 Felder) + §C.4 (Spindel ≤ 60 cm) + Anlage D s.2/4/6 (Grundvariante 1a: zweistieliger Gerüsthalter an jedem vierten Rahmenzug; unterste Ankerlage 4 m) + s.1/7; PERI Rosett 72 Assembly Instructions 09/2008 §B4.5.1-B4.5.2",
        "pageRefs": [
          "Anlage C",
          "§C.1",
          "§C.5",
          "§C.4",
          "Anlage D",
          "s.2",
          "s.1",
          "§B4.5.1-B4.5.2"
        ]
      },
      "page": "https://scafix.app/systems/peri-up"
    },
    {
      "system": "PERI UP Easy",
      "maker": "PERI",
      "type": "Frame",
      "bayLengthsM": [
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.67
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "PERI UP Easy",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-957 PERI UP Easy (16.05.2022, Bescheide 26.09.2022, 30.09.2024, 12.05.2025, b = 0,67 m, bis 16.05.2027) Anlage C S. 3–4 §C.5 (PDF S. 304–305), Anlage C S. 9 (PDF S. 310: mindestens zwei Gerüsthalter oder ein Dreiecksanker je Ankerlage), Anlage D S. 3 (PDF S. 322: Grundvariante 1a)",
        "pageRefs": [
          "Anlage C",
          "S. 3–4",
          "§C.5",
          "S. 304–305",
          "S. 9",
          "S. 310",
          "Anlage D",
          "S. 3",
          "S. 322"
        ]
      },
      "page": "https://scafix.app/systems/peri-up-easy"
    },
    {
      "system": "Pilosio MP",
      "maker": "Pilosio",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.83,
        1.15,
        2.5
      ],
      "depthsM": [
        0.83,
        1.15
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Pilosio MP",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 20,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "regulation",
        "source": "D.Lgs. 81/2008 art. 125 c. 6 «ancorato … ogni due piani di ponteggio e ad ogni due montanti, con disposizione di ancoraggi a rombo» (art. 138 c. 5), art. 133 c. 1 (oltre 20 m: progetto)",
        "pageRefs": []
      },
      "page": "https://scafix.app/systems/pilosio-mp"
    },
    {
      "system": "Plettac Contur",
      "maker": "Plettac",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.75,
        1,
        1.25,
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.74,
        1.06,
        1.39
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Plettac Contur",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.22-843 plettac contur (9.5.2019, forl. 19.3.2024 bis 3.4.2029) Anl. C §C.1, §C.5 s.1–2; Anl. D s.1; plettac contur AuV Dez. 2020 S. 10 (24 m), §2.4.5.1",
        "pageRefs": [
          "Anl. C",
          "§C.1",
          "§C.5",
          "s.1–2",
          "Anl. D",
          "s.1",
          "S. 10",
          "§2.4.5.1"
        ]
      },
      "page": "https://scafix.app/systems/plettac-contur"
    },
    {
      "system": "Plettac PD 70/100",
      "maker": "Plettac",
      "type": "Frame",
      "bayLengthsM": [
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Plettac PD 70/100",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4.6,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "plettac Distribution PD 70/100 Assembly and use manual (Ostrzeszów, July 2013, EN 12810-3N, certificate Z/002/034/25 valid 19.12.2025–18.12.2028) §1.1 pt 3/7/8 (PDF S. 5: max h 24 m), §3.1.3.6 (PDF S. 21), anchor drawings PDF S. 24–26 (● long anchors)",
        "pageRefs": [
          "§1.1",
          "S. 5",
          "§3.1.3.6",
          "S. 21",
          "S. 24–26"
        ]
      },
      "page": "https://scafix.app/systems/plettac-sl-70-100"
    },
    {
      "system": "Plettac SL 70 Alu",
      "maker": "Plettac",
      "type": "Frame",
      "bayLengthsM": [
        2.5,
        3
      ],
      "depthsM": [
        0.74
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Plettac SL 70 Alu",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-29.1 plettac SL 70-Alu (16.12.2020, verl. bis 03.01.2031) Anlage B §B.1 (PDF S. 110), §B.5 (PDF S. 111), Anlage C (3,00 m, teilweise offen: 4 m durchgehend)",
        "pageRefs": [
          "Anlage B",
          "§B.1",
          "S. 110",
          "§B.5",
          "S. 111",
          "Anlage C"
        ]
      },
      "page": "https://scafix.app/systems/plettac-sl-70-alu"
    },
    {
      "system": "Plettac SL 70/100",
      "maker": "Plettac",
      "type": "Frame",
      "bayLengthsM": [
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Plettac SL 70/100",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4.6,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-29 PLETTAC SL 70 (5.6.2020, endr. 29.10.2020, 28.5.2025 og 21.8.2026, bis 3.6.2030) Anl. B §B.1 (PDF S. 167), §B.5 a s.3–4, Tab. B.3 s.8, Anl. C s.6–8/17/18; Z-8.1-171 SL 100 (11.3.2019, bis 3.4.2029) §B.1, §B.5 a",
        "pageRefs": [
          "Anl. B",
          "§B.1",
          "S. 167",
          "§B.5",
          "s.3–4",
          "s.8",
          "Anl. C",
          "s.6–8"
        ]
      },
      "page": "https://scafix.app/systems/plettac-sl-70-100"
    },
    {
      "system": "Plettac Distribution (Modular)",
      "maker": "Plettac Distribution",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.7,
        1.1,
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.739,
        0.97
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Plettac Distribution (Modul)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Plettac Distribution «Instruction manual on assembly and use of PDM and PDM/c» (June 2025) §5.1 c (PDF S. 27: H = 24 m), §5.2.9 s. 28 (PDF p30), Fig. 30 (PDF S. 29: long anchors), §5.1 h; certificate Z/002/012/24 (1.8.2024–31.7.2027, covers the manual of 11.01.2019)",
        "pageRefs": [
          "§5.1",
          "S. 27",
          "§5.2.9",
          "s. 28",
          "PDF p30",
          "S. 29"
        ]
      },
      "page": "https://scafix.app/systems/plettac-distribution-pdm"
    },
    {
      "system": "Ponteggi Dalmine (Facade)",
      "maker": "Ponteggi Dalmine",
      "type": "Frame",
      "bayLengthsM": [
        1.8,
        2.5
      ],
      "depthsM": [
        0.75,
        1.05
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Ponteggi Dalmine (Fasade)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 20,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Marcegaglia Buildtech «Manuale di utilizzo – sistemi di ponteggio a telai prefabbricati» (07/2017) s. 32 «ogni 22 mq di ponteggio di facciata», s. 30 (> 20 m: progetto); D.Lgs. 81/2008 art. 125 c. 6 «ancorato … ogni due piani di ponteggio e ad ogni due montanti, con disposizione di ancoraggi a rombo» (art. 138 c. 5), art. 133 c. 1 (oltre 20 m: progetto)",
        "pageRefs": [
          "s. 32",
          "s. 30"
        ]
      },
      "page": "https://scafix.app/systems/ponteggi-dalmine-realpont"
    },
    {
      "system": "Ponteggi Dalmine (Modular)",
      "maker": "Ponteggi Dalmine",
      "type": "Modular, rosette",
      "bayLengthsM": [
        1.8,
        2.5,
        3
      ],
      "depthsM": [
        0.81,
        1.14
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Ponteggi Dalmine (Modul)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 20,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "regulation",
        "source": "D.Lgs. 81/2008 art. 125 c. 6 «ancorato … ogni due piani di ponteggio e ad ogni due montanti, con disposizione di ancoraggi a rombo» (art. 138 c. 5), art. 133 c. 1 (oltre 20 m: progetto)",
        "pageRefs": []
      },
      "page": "https://scafix.app/systems/ponteggi-dalmine-sm8"
    },
    {
      "system": "RARIS Alu (Facade)",
      "maker": "RARIS",
      "type": "Frame",
      "bayLengthsM": [
        2.5
      ],
      "depthsM": [
        0.7
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "RARIS Alu (Fasade)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 20,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "RARIS «Schele de faţadă — Manual de utilizare» s. 13 (ancorare < 20 m: cadre laterale din 4 în 4 m, celelalte din 8 în 8 m în zig-zag)",
        "pageRefs": [
          "s. 13"
        ]
      },
      "page": "https://scafix.app/systems/raris-alu"
    },
    {
      "system": "Ringer Doppelgeländer",
      "maker": "Ringer",
      "type": "Frame",
      "bayLengthsM": [
        2.5
      ],
      "depthsM": [
        0.65
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Ringer Doppelgeländer",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-858 Ringer Doppelgeländer (10.02.2020, verl. 11.02.2025 bis 14.02.2030) Anlage B §B.1 (PDF S. 51), §B.5 a–c, Anlage C S.1–S.7 (PDF S. 56–62)",
        "pageRefs": [
          "Anlage B",
          "§B.1",
          "S. 51",
          "§B.5",
          "Anlage C",
          "S.1",
          "S.7",
          "S. 56–62"
        ]
      },
      "page": "https://scafix.app/systems/ringer-doppelgelaender"
    },
    {
      "system": "ROLLE BLIZZARD S-70",
      "maker": "ROLLE",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ROLLE BLIZZARD S-70",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-974 ROLLE BLIZZARD S-70 (06.02.2025, geänd. 01.04.2026, bis 28.03.2031) Anlage B S. 3–4 §B.5 + Tab. B.2 (PDF S. 264–265), Anlage C S. 1 (PDF S. 276: Gerüsthalter \"lang\" oder Blitzanker), S. 20",
        "pageRefs": [
          "Anlage B",
          "S. 3–4",
          "§B.5",
          "S. 264–265",
          "Anlage C",
          "S. 1",
          "S. 276",
          "S. 20"
        ]
      },
      "page": "https://scafix.app/systems/rolle-blizzard-s-70"
    },
    {
      "system": "RUBO RK (klinowe)",
      "maker": "RUBO",
      "type": "Modular, wedge",
      "bayLengthsM": [
        2.09,
        2.53
      ],
      "depthsM": [
        0.65,
        0.95
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "RUBO RK (klinowe)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "regulation",
        "source": "Rozp. MI 6.02.2003 (Dz.U. 2003 nr 47 poz. 401) §115 ust. 1–3: siatkę kotew określa dokumentacja producenta lub projekt, ≥ 2,5 kN na kotwę, pomost ≤ 1,5 m nad najwyżej położoną linią kotew; siatka przyjęta (brak DTR RUBO online): Warbud BHP standard 2.2 (02.2018) s. 4 – kotwy co drugie pole i co drugą kondygnację, przesunięte o jedno pole, pion komunikacyjny z obu stron co 4 m; RUBO (rubo.pl, 23.10.2026): «up to a height of 24 m without additional static calculations»",
        "pageRefs": [
          "§115",
          "s. 4"
        ]
      },
      "page": "https://scafix.app/systems/rubo-rk"
    },
    {
      "system": "Scaffolding Center SC 70",
      "maker": "Scaffolding Center",
      "type": "Frame",
      "bayLengthsM": [
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.74
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Scaffolding Center SC 70",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-990 SC 70 (03.03.2026, 16.03.2026 – 16.03.2031) Anlage B S. 3–4 §B.5 a–c (PDF S. 184–185), Anlage C S. 6 (PDF S. 194: 1 Dreieckhalter je 5-Felder-Abschnitt, ① Anker bei teilweise offener Fassade), S. 10 (PDF S. 198: Netz 2 Dreieckhalter je 5-Felder-Abschnitt in jeder Ankerebene, nur gezeichnet, strengste Lesung 2 je angefangene 5 Felder), S. 11 (PDF S. 199: Plane, strengste Lesung 2 je angefangene 5 Felder), S. 32 (PDF S. 220: Kopplungsrohr unter allen Durchstiegen)",
        "pageRefs": [
          "Anlage B",
          "S. 3–4",
          "§B.5",
          "S. 184–185",
          "Anlage C",
          "S. 6",
          "S. 194",
          "S. 10",
          "S. 198",
          "S. 11",
          "S. 199",
          "S. 32",
          "S. 220"
        ]
      },
      "page": "https://scafix.app/systems/scaffolding-center-sc-70"
    },
    {
      "system": "Scaffolding Center SC 73",
      "maker": "Scaffolding Center",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Scaffolding Center SC 73",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-991 SC 73 (20.01.2022, bis 20.01.2027) Anlage B S. 4 §B.5 + Tab. B.2 (PDF S. 245–246), Anlage C S. 1 (PDF S. 256: Gerüsthalter \"lang\" oder Blitzanker)",
        "pageRefs": [
          "Anlage B",
          "S. 4",
          "§B.5",
          "S. 245–246",
          "Anlage C",
          "S. 1",
          "S. 256"
        ]
      },
      "page": "https://scafix.app/systems/scaffolding-center-sc-73"
    },
    {
      "system": "FRAMESCAFF 73",
      "maker": "Scafom-Rux",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "FRAMESCAFF 73",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-924 FRAMESCAFF 73 (05.07.2021, geänd. 02.09.2025, verl. 18.06.2026 bis 06.07.2031) Anlage B S. 3–4 §B.5 (PDF S. 255–256: «Unbekleidete Gerüste sind in Höhe 4 m durchgehend zu verankern»; Dreiecksanker nicht am Rand; Kopplungsrohre im Aufstiegsfeld unter Dreiecksankern), Anlage C S. 1 (PDF S. 262: durchgehende Gerüsthalter), S. 4 (Netz, Grundkonfiguration); 2 Dreiecksanker je angefangene 5 Felder nach S. 7 (PDF S. 268: Netz vor offener Fassade, 2 je 5-Felder-Abschnitt nur gezeichnet, strengste Lesung)",
        "pageRefs": [
          "Anlage B",
          "S. 3–4",
          "§B.5",
          "S. 255–256",
          "Anlage C",
          "S. 1",
          "S. 262",
          "S. 4",
          "S. 7",
          "S. 268"
        ]
      },
      "page": "https://scafix.app/systems/framescaff-73"
    },
    {
      "system": "Scafom-Rux RINGSCAFF",
      "maker": "Scafom-Rux",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.04,
        1.09,
        1.4,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09,
        1.4
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Scafom-Rux RINGSCAFF",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.22-869 RINGSCAFF (09.04.2021, geänd. 02.04.2025, verl. 20.03.2026 bis 11.04.2031) Anlage C S. 2 §C.5 (PDF S. 91: jeder Ständerzug alle 4 m, in der obersten Ebene jeder Ständerzug; 8 m versetzt nur mit U-Riegeln und durchgehender 4 m- und oberster Lage), Anlage D S. 01 (PDF S. 94: 1 V-Anker je Ankerlage auf 5 Feldern); Scafom-Rux AuV V20.1 (09/2020) S. 28–29 (V-Anker möglichst an beiden Enden)",
        "pageRefs": [
          "Anlage C",
          "S. 2",
          "§C.5",
          "S. 91",
          "Anlage D",
          "S. 01",
          "S. 94",
          "S. 28–29"
        ]
      },
      "page": "https://scafix.app/systems/scafom-rux-ringscaff"
    },
    {
      "system": "Scafom-Rux SUPER",
      "maker": "Scafom-Rux",
      "type": "Frame",
      "bayLengthsM": [
        2,
        2.5,
        3
      ],
      "depthsM": [
        1
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Scafom-Rux SUPER",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-185.2 RUX Super 100 (20.02.2023, bis 13.02.2028) Anlage B §B.5 a (PDF s. 131), Anlage C S.1 «8 m versetzt, Zusatzanker in H = 4 m», S.3 «Zusatzanker in H = 4 m, 20 m, 24 m»",
        "pageRefs": [
          "Anlage B",
          "§B.5",
          "s. 131",
          "Anlage C",
          "S.1",
          "S.3"
        ]
      },
      "page": "https://scafix.app/systems/scafom-rux-super"
    },
    {
      "system": "Scafom-Rux SUPER 65",
      "maker": "Scafom-Rux",
      "type": "Frame",
      "bayLengthsM": [
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.65
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Scafom-Rux SUPER 65",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-185.1 RUX SUPER 65 (30.06.2023, geänd. 23.01.2024, bis 05.01.2027) Anlage B §B.5 (PDF S. 153–154), Tab. B.3/B.4 (PDF S. 159–160), Anlage C S. 1 (PDF S. 163), S. 3 (PDF S. 165: Innen- und Außenkonsolen), S. 4 (PDF S. 166: Netz, 2 V-Halter im 5-Felder-Bild, strengste Lesung 2 je angefangene 5 Felder), S. 6 (PDF S. 168: Plane, jeder Knoten), S. 8 (PDF S. 170: Schutzwand, 2 V-Halter in der obersten Ankerlage)",
        "pageRefs": [
          "Anlage B",
          "§B.5",
          "S. 153–154",
          "S. 159–160",
          "Anlage C",
          "S. 1",
          "S. 163",
          "S. 3",
          "S. 165",
          "S. 4",
          "S. 166",
          "S. 6",
          "S. 168",
          "S. 8",
          "S. 170"
        ]
      },
      "page": "https://scafix.app/systems/scafom-rux-super-65"
    },
    {
      "system": "SGB CUPLOK",
      "maker": "SGB",
      "type": "Cuplock",
      "bayLengthsM": [
        1.25,
        1.3,
        1.8,
        2.5,
        3
      ],
      "depthsM": [
        1.3
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "SGB CUPLOK",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4.5,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "SGB CUPLOK® User Manual UK (Brand Energy & Infrastructure Services UK, 2016) s. 48 (PDF) «A. CUPLOK 2.0m lifts - 4m tie pattern · Horizontal spacing - every standard · Vertical spacing - maximum 4.0m», s. 36 Table 4 (8m tie pattern ≤ 4 lifts without foot ties), p31 rules 4 + 6, p32 «limit heights … to 12 lifts (24m)», p29 «unsheeted scaffolds only»; DIBt Z-8.22-208 (13.06.2022, bis 03.06.2027) Anlage C §C.2/§C.5 (PDF S. 48–49), Anlage D S. 1 (PDF S. 52: jeder Ständerzug alle 4 m, 1 V-Halter je 5 Felder, Hs ≤ 0,32); stepped and gable tops: every frame line tied at its own top level, more than the manual's «not more than two lifts above the last tied level» (p31 rule 3, p52)",
        "pageRefs": [
          "s. 48",
          "s. 36",
          "p31",
          "p32",
          "p29",
          "Anlage C",
          "§C.2",
          "§C.5",
          "S. 48–49",
          "Anlage D",
          "S. 1",
          "S. 52",
          "p52"
        ]
      },
      "page": "https://scafix.app/systems/sgb-cuplok"
    },
    {
      "system": "SIGMA (Facade)",
      "maker": "SIGMA",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.09,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "SIGMA (Fasade)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24.2,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "SIGMA 73LB DTR «Instrukcja montażu i użytkowania rusztowania SIGMA 73LB» §2.2.2 s. 12, §5.1, §5.3, §5.6, Rys. 21 s. 25; certyfikat B/015/25",
        "pageRefs": [
          "§2.2.2",
          "s. 12",
          "§5.1",
          "§5.3",
          "§5.6",
          "s. 25"
        ]
      },
      "page": "https://scafix.app/systems/sigma-73lb"
    },
    {
      "system": "SIGMA RTM (Wedge)",
      "maker": "SIGMA",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.73,
        1.04,
        1.09,
        1.4,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73,
        1.09
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "SIGMA RTM (Wedge)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24.2,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "SIGMA RTM DTR «Instrukcja montażu i użytkowania rusztowania modułowego SIGMA RTM» 09/2024 §5.1, §5.3 s. 29 (PDF), Rys. 31 s. 32; stepped and gable tops: every frame line tied at its own top level (§5.3 s. 29 «dodatkowe zakotwienia pierwszego i ostatniego poziomu»)",
        "pageRefs": [
          "§5.1",
          "§5.3",
          "s. 29",
          "s. 32"
        ]
      },
      "page": "https://scafix.app/systems/sigma-rtm"
    },
    {
      "system": "Solideq RAMSCAFF",
      "maker": "Solideq",
      "type": "Frame",
      "bayLengthsM": [
        0.73,
        1.07,
        1.57,
        2.07,
        2.57,
        3.07
      ],
      "depthsM": [
        0.73
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Solideq RAMSCAFF",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4.5,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24.5,
          "kind": "system-max"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Solideq RAMSCAFF, RISE sertifikat C900487 utg. 1 2022-10-01 (gyldig til 2032-10-01) s. 7 vilkår 6 + Monteringsanvisning Ramscaff 2022-02 (norsk) s. 33 §2.5.1, s. 34 fig. 4.3, s. 4 (maks. 24 m + 0,5 m); RISE typkontrollintyg SC0043-19 utg. 2 2022-03-31 (till 2029-06-04)",
        "pageRefs": [
          "s. 7",
          "s. 33",
          "§2.5.1",
          "s. 34",
          "s. 4"
        ]
      },
      "page": "https://scafix.app/systems/solideq-ramscaff"
    },
    {
      "system": "StepUp Cuplock",
      "maker": "StepUp",
      "type": "Cuplock",
      "bayLengthsM": [
        0.914,
        1.219,
        1.524,
        1.829,
        2.134,
        2.438,
        3.048
      ],
      "depthsM": [
        1.219,
        1.524
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "StepUp Cuplock",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 3.6,
        "firstTieDepthRatio": 4,
        "heightLimit": {
          "metres": 36.8,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "regulation",
        "source": "29 CFR § 1926.451(c)(1)(ii): first tie at the 4:1 height, then ≤ 20 ft (≤ 3 ft wide) / ≤ 26 ft (7.9 m) vertically, at each end and ≤ 30 ft (9.1 m) along (the same numbers reprinted in WACO ORN1701 p. 20 F «Scaffolding Safety Guidelines»). StepUp publishes no tie rule (StepUp catalogs 2024-02); 29 CFR § 1926.452(c)(6) (frame scaffolds) and (b)(10) (tube and coupler): over 125 ft (38.0 m) above the base plates designed by a registered professional engineer",
        "pageRefs": [
          "§ 1926.451",
          "p. 20",
          "§ 1926.452"
        ]
      },
      "page": "https://scafix.app/systems/stepup-cuplock"
    },
    {
      "system": "StepUp Frame & Brace",
      "maker": "StepUp",
      "type": "Frame",
      "bayLengthsM": [
        1.219,
        1.524,
        1.829,
        2.134,
        2.438,
        3.048
      ],
      "depthsM": [
        0.914,
        1.067,
        1.524
      ],
      "mainLiftHeightM": 1.9304,
      "tieRule": {
        "variant": "StepUp Frame & Brace",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": false
        },
        "firstTieAtOrBelowM": 3.6,
        "firstTieDepthRatio": 4,
        "heightLimit": {
          "metres": 36.8,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "regulation",
        "source": "29 CFR § 1926.451(c)(1)(ii): first tie at the 4:1 height, then ≤ 20 ft (≤ 3 ft wide) / ≤ 26 ft (7.9 m) vertically, at each end and ≤ 30 ft (9.1 m) along (the same numbers reprinted in WACO ORN1701 p. 20 F «Scaffolding Safety Guidelines»). StepUp publishes no tie rule (StepUp catalogs 2024-02); 29 CFR § 1926.452(c)(6) (frame scaffolds) and (b)(10) (tube and coupler): over 125 ft (38.0 m) above the base plates designed by a registered professional engineer",
        "pageRefs": [
          "§ 1926.451",
          "p. 20",
          "§ 1926.452"
        ]
      },
      "page": "https://scafix.app/systems/stepup-frame-and-brace"
    },
    {
      "system": "StepUp RingLock",
      "maker": "StepUp",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.914,
        1.219,
        1.524,
        1.829,
        2.13,
        2.438,
        3.05
      ],
      "depthsM": [
        0.732,
        1.09,
        1.286
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "StepUp RingLock",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 3.6,
        "firstTieDepthRatio": 4,
        "heightLimit": {
          "metres": 36.8,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "regulation",
        "source": "29 CFR § 1926.451(c)(1)(ii): first tie at the 4:1 height, then ≤ 20 ft (≤ 3 ft wide) / ≤ 26 ft (7.9 m) vertically, at each end and ≤ 30 ft (9.1 m) along (the same numbers reprinted in WACO ORN1701 p. 20 F «Scaffolding Safety Guidelines»). StepUp publishes no tie rule (StepUp catalogs 2024-02); 29 CFR § 1926.452(c)(6) (frame scaffolds) and (b)(10) (tube and coupler): over 125 ft (38.0 m) above the base plates designed by a registered professional engineer",
        "pageRefs": [
          "§ 1926.451",
          "p. 20",
          "§ 1926.452"
        ]
      },
      "page": "https://scafix.app/systems/stepup-ringlock"
    },
    {
      "system": "Tobler MATO",
      "maker": "Tobler",
      "type": "Frame",
      "bayLengthsM": [
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.7
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Tobler MATO",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "DIBt Z-8.1-937 Tobler MATO 1 (15.08.2022 bis 15.08.2027, Bescheide 07.02.2023, 02.01.2024, 10.06.2024) Anlage B §B.1 (PDF S. 87), §B.5, Anlage C S.1, S.4–S.6; stepped and gable tops: every frame line tied at its own top lift (Anlage B §B.5 S. 3, PDF S. 89 «In der obersten Gerüstlage ist jeder Ständer zu verankern»)",
        "pageRefs": [
          "Anlage B",
          "§B.1",
          "S. 87",
          "§B.5",
          "Anlage C",
          "S.1",
          "S.4",
          "S.6",
          "S. 3",
          "S. 89"
        ]
      },
      "page": "https://scafix.app/systems/tobler-mato"
    },
    {
      "system": "Tubesca-Comabi M368 (Modular)",
      "maker": "Tubesca-Comabi",
      "type": "Modular, wedge",
      "bayLengthsM": [
        0.8,
        1,
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.8,
        1
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Tubesca-Comabi M368 (Modul)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 3,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Tubesca-Comabi «Notice de montage M368/R200P/R200R» 100-00035775-ind.2 (09.2024) §14.1 s. 68 (cas 1: extrémités tous les 4 m, autres files tous les 8 m en quinconce, 24 m², «immédiatement au-dessous du plancher (ou maximum à 0.15 m)»), s. 69 (protection couvreur: chaque file au dernier niveau de plancher), §6.1 s. 34 (> 24 m: étude BEAC)",
        "pageRefs": [
          "§14.1",
          "s. 68",
          "s. 69",
          "§6.1",
          "s. 34"
        ]
      },
      "page": "https://scafix.app/systems/tubesca-comabi-m368"
    },
    {
      "system": "Tubesca-Comabi R200 Progress",
      "maker": "Tubesca-Comabi",
      "type": "Frame",
      "bayLengthsM": [
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.8
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Tubesca-Comabi R200 Progress",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 3,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Tubesca-Comabi «Notice de montage M368/R200P/R200R» 100-00035775-ind.2 (09.2024), R200 PROGRESS: §14.1 s. 68 (cas 1: extrémités tous les 4 m, autres files tous les 8 m en quinconce, 24 m², «immédiatement au-dessous du plancher (ou maximum à 0.15 m)»), s. 69 (protection couvreur: chaque file au dernier niveau de plancher), ch. 5 s. 30 (NR 24 / 20 / 16 m², R 12 / 10 / 8 m² pour une maille de 3 / 2,5 / 2 m), §6.1 s. 34 (> 24 m: étude BEAC)",
        "pageRefs": [
          "§14.1",
          "s. 68",
          "s. 69",
          "s. 30",
          "§6.1",
          "s. 34"
        ]
      },
      "page": "https://scafix.app/systems/tubesca-comabi-r200-progress"
    },
    {
      "system": "ULMA BRIO",
      "maker": "ULMA",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.7,
        1.02,
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.7,
        1.02
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ULMA BRIO",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": null,
        "estimate": true,
        "class": "manufacturer",
        "source": "ULMA Guía de Usuario Andamio Multidireccional BRIO, dok. 02FAN08, s.66/s.82/s.156-157 (1 feste per 24 m²)",
        "pageRefs": [
          "s.66",
          "s.82",
          "s.156-157"
        ]
      },
      "page": "https://scafix.app/systems/ulma-brio"
    },
    {
      "system": "Waco Frame (USA)",
      "maker": "Waco",
      "type": "Frame",
      "bayLengthsM": [
        1.524,
        2.134,
        3.048
      ],
      "depthsM": [
        0.914,
        1.524
      ],
      "mainLiftHeightM": 2.0066,
      "tieRule": {
        "variant": "Waco Frame (USA)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": false
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": 4,
        "heightLimit": {
          "metres": 36.8,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Waco RED frame scaffolding brochure ORN1701 (BrandSafway 2020) p. 20 «Scaffolding Safety Guidelines» F (SSFI): first tie at 4 × the minimum base, vertical ≤ 26 ft (7.9 m), at each end and ≤ 30 ft (9.1 m) along; 29 CFR § 1926.451(c)(1)(ii); 29 CFR § 1926.452(c)(6) (frame scaffolds) and (b)(10) (tube and coupler): over 125 ft (38.0 m) above the base plates designed by a registered professional engineer",
        "pageRefs": [
          "p. 20",
          "§ 1926.451",
          "§ 1926.452"
        ]
      },
      "page": "https://scafix.app/systems/waco-frame"
    },
    {
      "system": "WACO Narrow Frame (USA)",
      "maker": "Waco",
      "type": "Frame",
      "bayLengthsM": [
        1.524,
        2.134,
        2.438,
        3.048
      ],
      "depthsM": [
        0.702
      ],
      "mainLiftHeightM": 2.0066,
      "tieRule": {
        "variant": "WACO Narrow Frame (USA)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": false
        },
        "firstTieAtOrBelowM": 2.81,
        "firstTieDepthRatio": 4,
        "heightLimit": {
          "metres": 36.8,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "WACO ORN1701 p. 5 (Narrow Frame 2'-3 5/8\" × 6'-7\"); 29 CFR § 1926.451(c)(1)(ii): first tie at 4 × 2'-3 5/8\" = 9'-2 1/2\" (2.81 m), then ≤ 20 ft (≤ 3 ft wide) vertically, at each end and ≤ 30 ft along; 29 CFR § 1926.452(c)(6) (frame scaffolds) and (b)(10) (tube and coupler): over 125 ft (38.0 m) above the base plates designed by a registered professional engineer",
        "pageRefs": [
          "p. 5",
          "§ 1926.451",
          "§ 1926.452"
        ]
      },
      "page": "https://scafix.app/systems/waco-narrow-frame"
    },
    {
      "system": "WACO RED Access Frame (USA)",
      "maker": "Waco",
      "type": "Frame",
      "bayLengthsM": [
        1.524,
        1.829,
        2.134,
        2.438,
        3.048
      ],
      "depthsM": [
        1.524
      ],
      "mainLiftHeightM": 2.0066,
      "tieRule": {
        "variant": "WACO RED Access Frame (USA)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": false
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": 4,
        "heightLimit": {
          "metres": 36.8,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Waco RED frame scaffolding brochure ORN1701 (BrandSafway 2020) p. 20 «Scaffolding Safety Guidelines» F (SSFI): first tie at 4 × the minimum base, vertical ≤ 26 ft (7.9 m), at each end and ≤ 30 ft (9.1 m) along; 29 CFR § 1926.451(c)(1)(ii); 29 CFR § 1926.452(c)(6) (frame scaffolds) and (b)(10) (tube and coupler): over 125 ft (38.0 m) above the base plates designed by a registered professional engineer",
        "pageRefs": [
          "p. 20",
          "§ 1926.451",
          "§ 1926.452"
        ]
      },
      "page": "https://scafix.app/systems/waco-red-access-frame"
    },
    {
      "system": "WACO RED Box Frame (USA)",
      "maker": "Waco",
      "type": "Frame",
      "bayLengthsM": [
        1.219,
        1.524,
        1.829,
        2.134,
        2.438,
        3.048
      ],
      "depthsM": [
        0.914,
        1.524
      ],
      "mainLiftHeightM": 1.5494,
      "tieRule": {
        "variant": "WACO RED Box Frame (USA)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": false
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": 4,
        "heightLimit": {
          "metres": 36.8,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Waco RED frame scaffolding brochure ORN1701 (BrandSafway 2020) p. 20 «Scaffolding Safety Guidelines» F (SSFI): first tie at 4 × the minimum base, vertical ≤ 26 ft (7.9 m), at each end and ≤ 30 ft (9.1 m) along; 29 CFR § 1926.451(c)(1)(ii); 29 CFR § 1926.452(c)(6) (frame scaffolds) and (b)(10) (tube and coupler): over 125 ft (38.0 m) above the base plates designed by a registered professional engineer",
        "pageRefs": [
          "p. 20",
          "§ 1926.451",
          "§ 1926.452"
        ]
      },
      "page": "https://scafix.app/systems/waco-red-box-frame"
    },
    {
      "system": "Yagmur Iskele (H-Type)",
      "maker": "Yagmur",
      "type": "Frame",
      "bayLengthsM": [
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.75,
        1.05
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Yagmur Iskele (H-Type)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 3,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Yağmur «Güvenlikli İskele Sistemi Mamul El Kitabı» (2026-07) §9.1.9 s. 43 (ankraj: tüm panolar, 6 m kaplamasız, 4 m fileli, 2 m brandalı), s. 9 (24 m üzeri hesap)",
        "pageRefs": [
          "§9.1.9",
          "s. 43",
          "s. 9"
        ]
      },
      "page": "https://scafix.app/systems/yagmur-h-type"
    },
    {
      "system": "Yagmur Iskele (Ringlock)",
      "maker": "Yagmur",
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.75,
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.75,
        1.05
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Yagmur Iskele (Ringlock)",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 3,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "Yağmur «Flanşlı İskele Sistemi Mamul El Kitabı» (2026-07) §11 s. 66–68 (ankraj: 6 m kaplamasız, 4 m fileli, 2 m brandalı, 24 m), s. 9 (24 m üzeri hesap); NF «RAINSCAFF» (AFNOR NF 096)",
        "pageRefs": [
          "§11",
          "s. 66–68",
          "s. 9"
        ]
      },
      "page": "https://scafix.app/systems/yagmur-ringlock"
    },
    {
      "system": "Cup-lock JGJ 166 (China)",
      "maker": null,
      "type": "Cuplock",
      "bayLengthsM": [
        1.2,
        1.5
      ],
      "depthsM": [
        0.9,
        1.2
      ],
      "mainLiftHeightM": 1.8,
      "tieRule": {
        "variant": "Cup-lock JGJ 166 (China)",
        "verticalSpacingM": 3.6,
        "alongFace": {
          "kind": "spacing",
          "metres": 4.5,
          "staggered": false
        },
        "firstTieAtOrBelowM": 2.5,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 32.5,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "manufacturer",
        "source": "JGJ 166-2016 表6.2.1 (PDF s. 45–46: 二步三跨, 步距 1.8 m, 横距 0.9 / 1.2 m, 纵距 1.5 / 1.2 m, [H] 34–50 m by w0), §6.2.9-2 (PDF s. 48: «水平投影间距不得超过三跨，竖向垂直间距不得超过三步，… 悬臂高度不得超过两步»), §6.2.9-3 (PDF s. 49: 转角处、开口型端部, ≤ 层高且 ≤ 4m), §6.2.9-4, -7 (PDF s. 49: «从底层第一道水平杆处开始设置», «距架体碗扣主节点距离不应大于 300mm»)",
        "pageRefs": [
          "s. 45–46",
          "§6.2.9-2",
          "s. 48",
          "§6.2.9-3",
          "s. 49",
          "§6.2.9-4"
        ]
      },
      "page": "https://scafix.app/systems/cup-lock-jgj-166-china"
    },
    {
      "system": "Cuplock",
      "maker": null,
      "type": "Cuplock",
      "bayLengthsM": [
        1.25,
        1.3,
        1.8,
        2.5,
        3
      ],
      "depthsM": [
        1.3
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Cuplock",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-standard"
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 24,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "general",
        "source": null,
        "pageRefs": []
      },
      "page": "https://scafix.app/systems/cuplock"
    },
    {
      "system": "Japanese frame scaffold (枠組足場)",
      "maker": null,
      "type": "Frame",
      "bayLengthsM": [
        0.914,
        1.219,
        1.524,
        1.829
      ],
      "depthsM": [
        0.61,
        0.914,
        1.219
      ],
      "mainLiftHeightM": 1.7,
      "tieRule": {
        "variant": "Japanese frame scaffold (枠組足場)",
        "verticalSpacingM": 9,
        "alongFace": {
          "kind": "spacing",
          "metres": 8,
          "staggered": false
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 43.9,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "regulation",
        "source": "労働安全衛生規則 §570 第1項第5号イ (枠組足場: 垂直方向 9 m、水平方向 8 m 以下); 手すり先行工法等に関するガイドライン (基発1226第2号, 2023) 第6 1(4)ア «最上層に壁つなぎ又は控え»; 簡易枠 (幅 < 0.9 m) 5.5 m (e-ashiba p. 58); 45 m to the top handrail (Shinko p. 98); first row ≤ 4 m (the app's floor)",
        "pageRefs": [
          "§570",
          "p. 58",
          "p. 98"
        ]
      },
      "page": "https://scafix.app/systems/japanese-frame-scaffold"
    },
    {
      "system": "Japanese wedge scaffold A-type (くさび緊結式足場)",
      "maker": null,
      "type": "Modular, wedge",
      "bayLengthsM": [
        0.9,
        1.2,
        1.5,
        1.8
      ],
      "depthsM": [
        0.6,
        0.9,
        1.2
      ],
      "mainLiftHeightM": 1.8,
      "tieRule": {
        "variant": "Japanese wedge scaffold A-type (くさび緊結式足場)",
        "verticalSpacingM": 5,
        "alongFace": {
          "kind": "spacing",
          "metres": 5.5,
          "staggered": false
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 30,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "regulation",
        "source": "労働安全衛生規則 §570 第1項第5号イ (単管足場: 垂直方向 5 m、水平方向 5.5 m 以下); 仮設工業会「くさび緊結式足場の組立て及び使用に関する技術基準」 2015 年 改訂版 (the edition read; the 2020 改訂2版 and the 2024 認定編 exist and were not read) 第2章 1.(13) (PDF s. 3) «垂直方向 5.0ｍ以下、水平方向 5.5ｍ以下 … 緊結部付支柱と腕木の交点付近», 第3章 2.(15) (PDF s. 7) «最上層及び側端», 第2章 1.(14) «31ｍを超える … 2 本組み», 第1章 1 «高さ 45ｍ … 以下»; 手すり先行工法等に関するガイドライン (基発1226第2号, 2023) 第6 1(4)イ «最上層に壁つなぎ又は控え»; first row ≤ 4 m (the app's floor)",
        "pageRefs": [
          "§570",
          "s. 3",
          "s. 7"
        ]
      },
      "page": "https://scafix.app/systems/japanese-wedge-scaffold"
    },
    {
      "system": "Japanese wedge scaffold B-type (くさび緊結式足場)",
      "maker": null,
      "type": "Modular, wedge",
      "bayLengthsM": [
        0.9,
        1.2,
        1.5,
        1.8
      ],
      "depthsM": [
        0.6,
        0.9,
        1.2
      ],
      "mainLiftHeightM": 1.9,
      "tieRule": {
        "variant": "Japanese wedge scaffold B-type (くさび緊結式足場)",
        "verticalSpacingM": 5,
        "alongFace": {
          "kind": "spacing",
          "metres": 5.5,
          "staggered": false
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 30,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "regulation",
        "source": "労働安全衛生規則 §570 第1項第5号イ (単管足場: 垂直方向 5 m、水平方向 5.5 m 以下); 仮設工業会「くさび緊結式足場の組立て及び使用に関する技術基準」 2015 年 改訂版 (the edition read; the 2020 改訂2版 and the 2024 認定編 exist and were not read) 第2章 1.(13) (PDF s. 3) «垂直方向 5.0ｍ以下、水平方向 5.5ｍ以下 … 緊結部付支柱と腕木の交点付近», 第3章 2.(15) (PDF s. 7) «最上層及び側端», 第2章 1.(14) «31ｍを超える … 2 本組み», 第1章 1 «高さ 45ｍ … 以下»; 手すり先行工法等に関するガイドライン (基発1226第2号, 2023) 第6 1(4)イ «最上層に壁つなぎ又は控え»; first row ≤ 4 m (the app's floor)",
        "pageRefs": [
          "§570",
          "s. 3",
          "s. 7"
        ]
      },
      "page": "https://scafix.app/systems/japanese-wedge-scaffold"
    },
    {
      "system": "Korean system scaffold (시스템비계)",
      "maker": null,
      "type": "Modular, rosette",
      "bayLengthsM": [
        0.914,
        1.219,
        1.524,
        1.829
      ],
      "depthsM": [
        0.61,
        0.914,
        1.219
      ],
      "mainLiftHeightM": 1.9,
      "tieRule": {
        "variant": "Korean system scaffold (시스템비계)",
        "verticalSpacingM": 5,
        "alongFace": {
          "kind": "spacing",
          "metres": 5,
          "staggered": false
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 30,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "third-party",
        "source": "산업안전보건기준에 관한 규칙 제69조 제5호 (벽 연결재: 제조사가 정한 기준); KCS 21 60 10 : 2025 §3.2.4 (2) → §3.3.5 (1) «수직방향 5m 이하, 수평방향 5m 이하», §3.3.5 (2) «비계의 최상단과 가장자리 끝에도 벽 이음재»; KOSHA GUIDE D-C-7-2026 §7.4.2 (4) (s. 39; 31 m: 해당 전문가의 안전 확인); first row ≤ 4 m (the app's floor)",
        "pageRefs": [
          "§3.2.4",
          "§3.3.5",
          "§7.4.2",
          "s. 39"
        ]
      },
      "page": "https://scafix.app/systems/korean-system-scaffold"
    },
    {
      "system": "Kwikstage",
      "maker": null,
      "type": "Modular, wedge",
      "bayLengthsM": [
        0.762,
        0.81,
        1.27,
        1.83,
        2.44,
        3.05
      ],
      "depthsM": [
        0.762,
        1.27
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Kwikstage",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 30,
          "kind": "calculation"
        },
        "estimate": false,
        "class": "third-party",
        "source": "Waco Kwikform «Guidelines for safe use of scaffold – Wedgelok / Kwikstage» PPM51 (08/2013) s. 5 «Scaffold Ties» 1(a)/(b) + table «Tie configurations for scaffolds up to 30 metres» (each end + ≤ every 3rd standard, first ≤ 4.0 m, ≤ 4.0 m up; above 20 m: end 10 % every standard, next 10 % every 2nd), note «above 30.0m, engineering advice»",
        "pageRefs": [
          "s. 5"
        ]
      },
      "page": "https://scafix.app/systems/kwikstage"
    },
    {
      "system": "Rusztowanie warszawskie",
      "maker": null,
      "type": "Frame",
      "bayLengthsM": [
        1.58
      ],
      "depthsM": [
        1.58
      ],
      "mainLiftHeightM": 1.7333,
      "tieRule": {
        "variant": "Rusztowanie warszawskie",
        "verticalSpacingM": 1.7333,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 4.6,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "regulation",
        "source": "Rozp. MI 6.02.2003 (Dz.U. 2003 nr 47 poz. 401) §115 ust. 1–3: siatkę kotew określa dokumentacja producenta lub projekt, ≥ 2,5 kN na kotwę, pomost ≤ 1,5 m nad najwyżej położoną linią kotew; siatka przyjęta (UTLEDET): Warbud BHP 2.2 (02.2018) s. 4 (co drugie pole, co drugą kondygnację = co drugi poziom 0,867 m); POLBRAM DTR «Rusztowanie warszawskie» (2021) Roz. IV Typ 3 «Maksymalna wysokość pomostu roboczego – 4,60 m», Roz. VI pkt 2.10–2.11 (kotwić powyżej 2,00 m, z obydwu stron), pkt 5 (konstrukcja odmienna lub pomost powyżej 4,60 m: projekt)",
        "pageRefs": [
          "§115",
          "s. 4"
        ]
      },
      "page": "https://scafix.app/systems/rusztowanie-warszawskie"
    },
    {
      "system": "Shoring / falsework",
      "maker": null,
      "type": "Shoring",
      "bayLengthsM": [
        1,
        1.5,
        2,
        2.5
      ],
      "depthsM": [
        1.3
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Understøttelse / falsework",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": null,
        "estimate": true,
        "class": "general",
        "source": null,
        "pageRefs": []
      },
      "page": null
    },
    {
      "system": "Tube & coupler",
      "maker": null,
      "type": "Tube and coupler",
      "bayLengthsM": [
        1,
        1.2,
        1.5,
        2,
        2.4
      ],
      "depthsM": [
        0.73,
        1.09,
        1.4
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "Rør & kobling",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "spacing",
          "metres": 6,
          "staggered": false
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": null,
        "estimate": true,
        "class": "general",
        "source": null,
        "pageRefs": []
      },
      "page": null
    },
    {
      "system": "Tube & coupler JGJ 130 (China)",
      "maker": null,
      "type": "Tube and coupler",
      "bayLengthsM": [
        1.2,
        1.5
      ],
      "depthsM": [
        1.05,
        1.3
      ],
      "mainLiftHeightM": 1.8,
      "tieRule": {
        "variant": "Tube & coupler JGJ 130 (China)",
        "verticalSpacingM": 3.6,
        "alongFace": {
          "kind": "spacing",
          "metres": 4.5,
          "staggered": false
        },
        "firstTieAtOrBelowM": 2.5,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 28.8,
          "kind": "calculation"
        },
        "estimate": true,
        "class": "manufacturer",
        "source": "JGJ 130-2011 表6.1.1-1 (s. 27, PDF s. 36: 二步三跨, lb 1.05 / 1.30 m, h 1.80 m, [H] 32 / 30 m, w0 = 0.4 kN/m²), 表6.4.2 (PDF s. 41: 竖向 ≤ 3h, 水平 ≤ 3la, ≤ 40 m²), §6.4.3 (PDF s. 41–42: «偏离主节点的距离不应大于 300mm», «从底层第一步纵向水平杆处开始设置»), §6.4.4 (PDF s. 42: 开口型两端, ≤ 层高且 ≤ 4m); GB 55023-2022 §4.4.6 (≤ 3 跨 × 3 步; 悬臂高度 ≤ 2 步)",
        "pageRefs": [
          "s. 27",
          "s. 36",
          "s. 41",
          "§6.4.3",
          "s. 41–42",
          "§6.4.4",
          "s. 42",
          "§4.4.6"
        ]
      },
      "page": "https://scafix.app/systems/tube-and-coupler-jgj-130-china"
    },
    {
      "system": "ЛРСП-40",
      "maker": null,
      "type": "Frame",
      "bayLengthsM": [
        2,
        2.5,
        3
      ],
      "depthsM": [
        0.976
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ЛРСП-40",
        "verticalSpacingM": 2,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 40,
          "kind": "system-max"
        },
        "estimate": false,
        "class": "manufacturer",
        "source": "ЛРСП-40 паспорт (ТУ 5225-001-11713507-04) §4.5 с. 6 «через 4м в шахматном порядке», с. 8 «Схема крепления лесов к стене» (каждый ярус с 4 м, стойки через одну, в шахматном порядке), §2.1 «Максимальная высота лесов, м 40»; Приказ Минтруда № 782н п. 89",
        "pageRefs": [
          "§4.5",
          "§2.1"
        ]
      },
      "page": "https://scafix.app/systems/lrsp-40"
    },
    {
      "system": "ЛСК-60",
      "maker": null,
      "type": "Modular, rosette",
      "bayLengthsM": [
        1,
        1.2,
        1.5,
        2,
        2.5,
        3
      ],
      "depthsM": [
        1,
        1.2
      ],
      "mainLiftHeightM": 2,
      "tieRule": {
        "variant": "ЛСК-60",
        "verticalSpacingM": 4,
        "alongFace": {
          "kind": "every-nth",
          "n": 2,
          "staggered": true
        },
        "firstTieAtOrBelowM": 4,
        "firstTieDepthRatio": null,
        "heightLimit": {
          "metres": 60,
          "kind": "system-max"
        },
        "estimate": true,
        "class": "third-party",
        "source": "Приказ Минтруда России № 782н (ред. 29.04.2025) п. 89 (крайние стойки через ярус, верхний ярус через два пролета, 1 крепление на 50 м²); ЛСК-60 паспорт s. 3 «согласно ППР», Tab. 1 «Максимальная высота лесов, м 60»",
        "pageRefs": [
          "s. 3"
        ]
      },
      "page": "https://scafix.app/systems/lsk-60"
    }
  ]
}
